Hybrid closed‐loop glucose control with faster insulin aspart compared with standard insulin aspart in adults with type 1 diabetes: A double‐blind, multicentre, multinational, randomized, crossover study
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Aim: To evaluate the use of hybrid closed‐loop glucose control with faster‐acting insulin aspart (Fiasp) in adults with type 1 diabetes (T1D). Research Design and Methods: In a double‐blind, multinational, randomized, crossover study, 25 adults with T1D using insulin pump therapy (mean ± SD, age 38 ± 9 years, HbA1c 7.4% ± 0.8% [57 ± 8 mmol/mol]) underwent two 8‐week periods of unrestricted living comparing hybrid closed‐loop with Fiasp and hybrid closed‐loop with standard insulin aspart in random order. During both interventions the CamAPS FX closed‐loop system incorporating the Cambridge model predictive control algorithm was used. Results: In an intention‐to‐treat analysis, the proportion of time sensor glucose was in the target range (3.9–10.0 mmol/L; primary endpoint) was not different between interventions (75% ± 8% vs. 75% ± 8% for hybrid closed‐loop with Fiasp vs. hybrid closed‐loop with standard insulin aspart; mean‐adjusted difference −0.6% [95% CI −1.8% to 0.7%]; p < .001 for non‐inferiority [non‐inferiority margin 5%]). The proportion of time with sensor glucose less than 3.9 mmol/L (median [IQR] 2.4% [1.2%–3.2%] vs. 2.9% [1.7%–4.0%]; p = .01) and less than 3.0 mmol/L (median [IQR] 0.4% [0.2%–0.7%] vs. 0.7% [0.2%–0.9%]; p = .03) was reduced with Fiasp versus standard insulin aspart. There was no difference in mean glucose (8.1 ± 0.8 vs. 8.0 ± 0.8 mmol/L; p = .13) or glucose variability (SD of sensor glucose 2.9 ± 0.5 vs. 2.9 ± 0.5 mmol/L; p = .90). Total daily insulin requirements did not differ (49 ± 15 vs. 49 ± 15 units/day; p = .45). No severe hypoglycaemia or ketoacidosis occurred. Conclusions: The use of Fiasp in the CamAPS FX closed‐loop system may reduce hypoglycaemia without compromising glucose control compared with standard insulin aspart in adults with T1D.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the adaptive control of the false discovery rate in multiple testing with independent statistics
Benjamini, Y., & Hochberg, Y. (2000) · Journal of Educational and Behavioral Statistics · doi:10.3102/10769986025001060 · Cited by 2,015
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Tauschmann, M., Thabit, H., Bally, L., Allen, J. M., Hartnell, S., Wilinska, M. E., Ruan, Y., Sibayan, J., Kollman, C., Cheng, P., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31947-0 · Cited by 440
Self-citationBekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Self-citationOne year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215
Hypoglycemia in Type 1 Diabetes Mellitus
Cryer, P. E. (2010) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2010.05.003 · Cited by 205
Heise, T., Pieber, T. R., Danne, T., Erichsen, L., & Haahr, H. (2017) · Clinical Pharmacokinetics · doi:10.1007/s40262-017-0514-8 · Cited by 182
Cited by
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citationA Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Hu, X., White, K., Young, C., Olroyd, A. G., Kievit, P., Connolly, A. J., Deuse, T., & Schrepfer, S. (2024) · Cell Stem Cell · doi:10.1016/j.stem.2024.02.001 · Cited by 73
The role of automated insulin delivery technology in diabetes
Boughton, C. K., & Hovorka, R. (2024) · Diabetologia · doi:10.1007/s00125-024-06165-w · Cited by 57
Self-citationGarcia-Tirado, J., Diaz, J. L., Esquivel-Zuniga, R., Koravi, C. L. K., Corbett, J. P., Dawson, M., Wakeman, C., Barnett, C. L., Oliveri, M. C., Myers, H., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0932 · Cited by 52
Metadata
- Authors
- Boughton, C. K., Hartnell, S., Thabit, H., Poettler, T., Herzig, D., Wilinska, M. E., Ashcroft, N. L., Sibayan, J., Cohen, N., Calhoun, P., Bally, L., Mader, J. K., Evans, M., Leelarathna, L., & Hovorka, R.
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 2021-03-08
- Volume
- 23
- Issue
- 6
- Pages
- 1389-1396
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W3131710019
- Cited by
- 96
- References
- 7
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.