CoChat

Hybrid closed‐loop glucose control with faster insulin aspart compared with standard insulin aspart in adults with type 1 diabetes: A double‐blind, multicentre, multinational, randomized, crossover study

Open access
Boughton, Charlotte K., Hartnell, Sara, Thabit, Hood, Poettler, Tina, Herzig, David, Wilinska, Malgorzata E., Ashcroft, Nicole L., Sibayan, Judy, Cohen, Nathan, Calhoun, Peter, Bally, Lia, Mader, Julia K., Evans, Mark, Leelarathna, Lalantha, Hovorka, Roman · 2021 · Diabetes, Obesity and Metabolism
Cited by 96

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Aim: To evaluate the use of hybrid closed‐loop glucose control with faster‐acting insulin aspart (Fiasp) in adults with type 1 diabetes (T1D). Research Design and Methods: In a double‐blind, multinational, randomized, crossover study, 25 adults with T1D using insulin pump therapy (mean ± SD, age 38 ± 9 years, HbA1c 7.4% ± 0.8% [57 ± 8 mmol/mol]) underwent two 8‐week periods of unrestricted living comparing hybrid closed‐loop with Fiasp and hybrid closed‐loop with standard insulin aspart in random order. During both interventions the CamAPS FX closed‐loop system incorporating the Cambridge model predictive control algorithm was used. Results: In an intention‐to‐treat analysis, the proportion of time sensor glucose was in the target range (3.9–10.0 mmol/L; primary endpoint) was not different between interventions (75% ± 8% vs. 75% ± 8% for hybrid closed‐loop with Fiasp vs. hybrid closed‐loop with standard insulin aspart; mean‐adjusted difference −0.6% [95% CI −1.8% to 0.7%]; p < .001 for non‐inferiority [non‐inferiority margin 5%]). The proportion of time with sensor glucose less than 3.9 mmol/L (median [IQR] 2.4% [1.2%–3.2%] vs. 2.9% [1.7%–4.0%]; p = .01) and less than 3.0 mmol/L (median [IQR] 0.4% [0.2%–0.7%] vs. 0.7% [0.2%–0.9%]; p = .03) was reduced with Fiasp versus standard insulin aspart. There was no difference in mean glucose (8.1 ± 0.8 vs. 8.0 ± 0.8 mmol/L; p = .13) or glucose variability (SD of sensor glucose 2.9 ± 0.5 vs. 2.9 ± 0.5 mmol/L; p = .90). Total daily insulin requirements did not differ (49 ± 15 vs. 49 ± 15 units/day; p = .45). No severe hypoglycaemia or ketoacidosis occurred. Conclusions: The use of Fiasp in the CamAPS FX closed‐loop system may reduce hypoglycaemia without compromising glucose control compared with standard insulin aspart in adults with T1D.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.14355

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Boughton, C. K., Hartnell, S., Thabit, H., Poettler, T., Herzig, D., Wilinska, M. E., Ashcroft, N. L., Sibayan, J., Cohen, N., Calhoun, P., Bally, L., Mader, J. K., Evans, M., Leelarathna, L., & Hovorka, R.
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2021-03-08
Volume
23
Issue
6
Pages
1389-1396
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W3131710019
Cited by
96
References
7
FWCI
11.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.