Field measurement of ventilation rates
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Ventilation rates have significant impacts on building energy use and indoor contaminant concentrations, making them key parameters in building performance. Ventilation rates have been measured in buildings for many decades, and there are mature measurement approaches available to researchers and others who need to know actual ventilation rates in buildings. Despite the fact that ventilation rates are critical in interpreting indoor concentration measurements, it is disconcerting how few Indoor Air Quality field studies measure ventilation rates or otherwise characterize the ventilation design of the study building(s). This paper summarizes parameters of interest in characterizing building ventilation, available methods for quantifying these parameters, and challenges in applying these methods to different types of buildings and ventilation systems. These parameters include whole-building air change rates, system outdoor air intake rates, and building infiltration rates. Tracer gas methods are reviewed as well as system airflow rate measurements using, for example, duct traverses. Several field studies of ventilation rates conducted over the past 75 years are described to highlight the approaches employed and the findings obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Konz, J. J., Lisi, K., Friebele, E., & Dixon, D. (1989) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 2,219
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Self-citationBuilding ventilation: theory and measurement
(1997) · Choice Reviews Online · doi:10.5860/choice.35-2135 · Cited by 734
Tracer-gas techniques for measuring ventilation in a single zone
Sherman, M. H. (1990) · Building and Environment · doi:10.1016/0360-1323(90)90010-o · Cited by 291
WALLACE, L. A., EMMERICH, S. J., & HOWARD-REED, C. (2002) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500229 · Cited by 260
European Indoor Air Quality Audit Project in 56 Office Buildings
Bluyssen, P. M., Oliveira Fernandes, E., Groes, L., Clausen, G., Fanger, P. O., Valbjorn, O., Bernhard, C. A., & Roulet, C. A. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.00002.x · Cited by 237
Modeled infiltration rate distributions for U.S. housing
Persily, A. K., Musser, A., & Emmerich, S. J. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00669.x · Cited by 156
Self-citationDietz, R., Goodrich, R., Cote, E., & Wieser, R. (1986) · Measured Air Leakage of Buildings · doi:10.1520/stp19649s · Cited by 108
Indoor air quality in sustainable, energy efficient buildings
Persily, A. K., & Emmerich, S. J. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2011.592106 · Cited by 99
Self-citationVentilation and indoor air quality in new homes
Crump, D., Dimitroulopoulou, S., Squire, R. W., Ross, D., Pierce, B., White, M., Brown, V. M., & Coward, S. (2005) · Pollution atmosphérique · Cited by 97
Nabinger, S. J., & Persily, A. K. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.07.027 · Cited by 84
Self-citationNatural ventilation design: An analysis of predicted and measured performance
Belleri, A., Lollini, R., & Dutton, S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.06.009 · Cited by 64
Ventilation Research in Occupied Houses.
Dick, J. B., & Thomas, D. (1951) · Cited by 56
California residential air exchange rates and residence volumes.
Wilson, A. L., Sd, C., Tian, Y., Becker, E. W., Pe, B., Dw, B., Billick, I. H., & Ca, G. (1996) · PubMed · Cited by 53
Measuring ventilation rates in the Swedish housing stock
Stymne, H., Boman, C. A., & Kronvall, J. (1994) · Building and Environment · doi:10.1016/0360-1323(94)90037-x · Cited by 46
European audit project to optimise indoor air quality and energy consumption in office buildings
Bluyssen, P. M., Fernandes, E. D. O., Fanger, P. O., Groes, L., Glausen, G., Roulet, C.-A., Bernhard, C., & Valbjørn, O. (1994) · Cited by 39
Persily, A. K., & Gorfain, J. (2008) · doi:10.6028/nist.ir.7145r · Cited by 34
Self-citationThe Fundamentals of Natural Ventilation of Houses.
Dick, J. B. (1950) · Cited by 30
Field measurements of air infiltration in ten elec-trically-heated houses.
Coblentz, C. W., & Achenbach, P. (1963) · Cited by 26
Air Change Effectiveness Measurements in Two Modern Office Buildings
Persily, A. K., Dols, W. S., & Nabinger, S. J. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-3-00006.x · Cited by 19
Self-citationSimultaneous measurements of infiltration and intake in an office building
Persily, A. K., & Norford, L. K. (1987) · ASHRAE winter conference papers · Cited by 16
Self-citationMeasurements of the ventilation of dwellings
Warner, C. G. (1940) · Journal of Hygiene · doi:10.1017/s0022172400027728 · Cited by 16
The Helsinki Office Environment Study: Air Change in Mechanically Ventilated Buildings
Teijonsalo, J., Jaakkola, J. J. K., & Seppaunen, O. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-2-00007.x · Cited by 15
Measurements of Air Infiltration and Airtightness in Passive Solar Homes
Persily, A. (1986) · doi:10.1520/stp19640s · Cited by 8
Self-citationFisk, W. J., USDOE. Assistant Secretary for Energy Efficiency and Renewable Energy. Office of the Deputy Assistant Secretary for Technology Development. Office of the Building Technologies Program (US), Faulkner, D., & Sullivan, D. P. (2004) · doi:10.2172/838253 · Cited by 8
Fisk, W. J., Sullivan, D. P., Cohen, S., & Han, H. (2008) · doi:10.2172/944427 · Cited by 6
Cited by
Wolkoff, P., Azuma, K., & Carrer, P. (2021) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2021.113709 · Cited by 279
Batterman, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14020145 · Cited by 271
Formaldehyde sources, formaldehyde concentrations and air exchange rates in European housings
Salthammer, T. (2019) · Building and Environment · doi:10.1016/j.buildenv.2018.12.042 · Cited by 245
Metadata
- Authors
- Persily, A. K.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2015-03-18
- Volume
- 26
- Issue
- 1
- Pages
- 97-111
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2118061583
- Cited by
- 164
- References
- 28
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.