The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Short-range airborne transmission of expiratory droplets between two people
Abstract
The occurrence of close proximity infection for many respiratory diseases is often cited as evidence of large droplet and/or close contact transmission. We explored interpersonal exposure of exhaled droplets and droplet nuclei of two standing thermal manikins as affected by distance, humidity, ventilation, and breathing mode. Under the specific set of conditions studied, we found a substantial increase in airborne exposure to droplet nuclei exhaled by the source manikin when a susceptible manikin is within about 1.5 m of the source manikin, referred to as the proximity effect. The threshold distance of about 1.5 m distinguishes the two basic transmission processes of droplets and droplet nuclei, that is, short-range modes and the long-range airborne route. The short-range modes include both the conventional large droplet route and the newly defined short-range airborne transmission. We thus reveal that transmission occurring in close proximity to the source patient includes both droplet-borne (large droplet) and short-range airborne routes, in addition to the direct deposition of large droplets on other body surfaces. The mechanisms of the droplet-borne and short-range airborne routes are different; their effective control methods also differ. Neither the current droplet precautions nor dilution ventilation prevents short-range airborne transmission, so new control methods are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
Self-citationToward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803
Transmission of influenza A in human beings
Brankston, G., Gitterman, L., Hirji, Z., Lemieux, C., & Gardam, M. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70029-4 · Cited by 744
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Tang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
Self-citationExhaled droplets due to talking and coughing
Xie, X., Li, Y., Sun, H., & Liu, L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0388.focus · Cited by 527
Self-citationThe Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473
Zhu, S., Kato, S., & Yang, J.-H. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.06.024 · Cited by 428
Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423
Dilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386
Evaporation and dispersion of respiratory droplets from coughing
Liu, L., Wei, J., Li, Y., & Ooi, A. (2017) · Indoor Air · doi:10.1111/ina.12297 · Cited by 325
Self-citationEnhanced spread of expiratory droplets by turbulence in a cough jet
Wei, J., & Li, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.06.018 · Cited by 321
Self-citationTang, J. W., Liebner, T. J., Craven, B. A., & Settles, G. S. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0295.focus · Cited by 300
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298
Bjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294 · cited 9×
“Exposure between two face-to-face breathing thermal manikins was first measured by Bjørn and Nielsen (2002) in a room with displacement ventilation. Qian et al. (2006) extended this study to two recumbent patients in a ward.”
MethodInfluentialSelf-citationQian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00407.x · Cited by 294
Self-citationFace masks to prevent transmission of influenza virus: a systematic review
COWLING, B. J., ZHOU, Y., IP, D. K. M., LEUNG, G. M., & AIELLO, A. E. (2010) · Epidemiology and Infection · doi:10.1017/s0950268809991658 · Cited by 274
Modeling particle dispersion and deposition in indoor environments
Gao, N. P., & Niu, J. L. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.01.016 · Cited by 273
Cluster of SARS among Medical Students Exposed to Single Patient, Hong Kong
Wong, T.-W., Lee, C.-K., Tam, W., Lau, J. T.-F., Yu, T.-S., Lui, S.-F., Chan, P. K. S., Li, Y., Bresee, J. S., Sung, J. J. Y., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030452 · Cited by 265
Self-citationChen, C., & Zhao, B. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00626.x · Cited by 251
Methods for air cleaning and protection of building occupants from airborne pathogens
Bolashikov, Z. D., & Melikov, A. K. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.09.001 · Cited by 228
Transport of expiratory droplets in an aircraft cabin
Gupta, J. K., Lin, C.-H., & Chen, Q. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00676.x · Cited by 214
Quantifying the Routes of Transmission for Pandemic Influenza
Atkinson, M. P., & Wein, L. M. (2008) · Bulletin of Mathematical Biology · doi:10.1007/s11538-007-9281-2 · Cited by 213
Relative Contributions of Four Exposure Pathways to Influenza Infection Risk
Nicas, M., & Jones, R. M. (2009) · Risk Analysis · doi:10.1111/j.1539-6924.2009.01253.x · Cited by 190
Olmedo, I., Nielsen, P. V., Ruiz de Adana, M., Jensen, R. L., & Grzelecki, P. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00736.x · Cited by 183
Self-citationQian, H., & Li, Y. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00653.x · Cited by 149
Self-citationWan, M. P., Sze-To, G. N., Chao, C. Y. H., Fang, L., & Melikov, A. K. (2009) · Aerosol Science and Technology · doi:10.1080/02786820802641461 · Cited by 132
Single-exhalation profiles of NO and CO2in humans: effect of dynamically changing flow rate
Tsoukias, N. M., Tannous, Z., Wilson, A. F., & George, S. C. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.642 · Cited by 126
Sze-To, G. N., Wan, M. P., Chao, C. Y. H., Fang, L., & Melikov, A. K. (2009) · Aerosol Science and Technology · doi:10.1080/02786820902736658 · Cited by 124
Yang, J., Sekhar, C., Cheong, D. K. W., & Raphael, B. (2014) · Indoor Air · doi:10.1111/ina.12127 · Cited by 105
Transport and Removal of Expiratory Droplets in Hospital Ward Environment
Chao, C. Y. H., Wan, M. P., & To, G. N. S. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802104973 · Cited by 93
HUMAN PULMONARY SECRETIONS IN HEALTH AND DISEASE
Potter, J. L., Matthews, L. W., Lemm, J., & Spector, S. S. (1963) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1963.tb16677.x · Cited by 91
The risk of airborne cross-infection in a room with vertical low-velocity ventilation
Olmedo, I., Nielsen, P. V., de Adana, M. R., & Jensen, R. L. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00794.x · Cited by 85
Self-citationHan, K., Zhu, X., He, F., Liu, L.-G., Zhang, L., Ma, H., Tang, X., Huang, T., Zeng, G. Q., & Zhu, B. (2009) · Emerging infectious diseases · doi:10.3201/eid1510.091013 · Cited by 81
Self-citationLoudon, R. G., & ROBERTS, R. M. (1967) · Nature · doi:10.1038/213095a0 · Cited by 71
Licina, D., Melikov, A., Pantelic, J., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12177 · Cited by 69
Parotid saliva protein profiles in caries-free and caries-active adults
Dodds, M. W. J., Johnson, D. A., Mobley, C. C., & Hattaway, K. M. (1997) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/s1079-2104(97)90012-3 · Cited by 67
Pantelic, J., Tham, K. W., & Licina, D. (2015) · Indoor Air · doi:10.1111/ina.12187 · Cited by 61
Personal Exposure to Contaminant Sources in Ventilated Rooms
Brohus, H. (1997) · VBN Forskningsportal (Aalborg Universitet) · Cited by 56
The Sources and Modes of Infection
ERNST, H. C. (1911) · Science · doi:10.1126/science.34.868.215 · Cited by 43
The epidemiology of the common cold. I
Lidwell, O. M., & Williams, R. E. O. (1961) · Journal of Hygiene · doi:10.1017/s0022172400038973 · Cited by 28
The Transmission of Respiratory Infections
Hare, R. (1964) · Proceedings of the Royal Society of Medicine · doi:10.1177/003591576405700329 · Cited by 21
Cited by
How can airborne transmission of COVID-19 indoors be minimised?
Morawska, L., Tang, J. W., Bahnfleth, W., Bluyssen, P. M., Boerstra, A., Buonanno, G., Cao, J., Dancer, S., Floto, A., Franchimon, F., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105832 · Cited by 1,343
Self-citationTransmissibility and transmission of respiratory viruses
Leung, N. H. L. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-021-00535-6 · Cited by 890
Recognition of aerosol transmission of infectious agents: a commentary
Tellier, R., Li, Y., Cowling, B. J., & Tang, J. W. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3707-y · Cited by 746
Self-citationThe efficacy of social distance and ventilation effectiveness in preventing COVID-19 transmission
Sun, C., & Zhai, Z. (2020) · Sustainable Cities and Society · doi:10.1016/j.scs.2020.102390 · Cited by 636
Infectious virus in exhaled breath of symptomatic seasonal influenza cases from a college community
Yan, J., Grantham, M., Pantelic, J., Bueno de Mesquita, P. J., Albert, B., Liu, F., Ehrman, S., Milton, D. K., EMIT Consortium, Adamson, W., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716561115 · Cited by 534
Metadata
- Authors
- Liu, L., Li, Y., Nielsen, P. V., Wei, J., & Jensen, R. L.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2016-07-09
- Volume
- 27
- Issue
- 2
- Pages
- 452-462
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2413990308
- Cited by
- 310
- References
- 44
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.