Thrombin generation testing in routine clinical practice: are we there yet?
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Summary: Thrombin is the central enzyme in the coagulation cascade. Estimation of an individual’s potential to generate thrombin may correlate more closely with a hyper‐ or hypo‐coagulable phenotype, compared to traditional coagulation tests. The possible correlation and recent technical advances in thrombin generation measurement has caused a significant interest in the method and the development of commercial assays. Several variations of the assay exist depending on the defect to be investigated. Fluorogenic thrombin generation assays have acceptable intra‐laboratory variation but a higher inter‐laboratory variation. Variation in preanalytical variables makes comparisons between studies difficult. Thrombin generation is highly variable between individuals and there are suggestions that this may allow individualized treatment based on global haemostatic response in patients with bleeding disorders or on anticoagulant therapy. In patients with thrombotic disorders it may be possible to identify those at higher risk of recurrent thrombosis. For both scenarios, however, data from large prospective studies are lacking or inconclusive and a good relationship between thrombin generation and phenotype remains to be established. Further standardization of the assay is needed before large multicentre studies can be conducted and until then thrombin generation in routine clinical practice is not yet a reality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Cell-based Model of Hemostasis
Monroe, D., & Hoffman, M. (2001) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1615947 · Cited by 1,542
Calibrated Automated Thrombin Generation Measurement in Clotting Plasma
Hemker, H. C., Giesen, P., Al Dieri, R., Regnault, V., de Smedt, E., Wagenvoord, R., Lecompte, T., & Béguin, S. (2003) · Pathophysiology of Haemostasis and Thrombosis · doi:10.1159/000071636 · Cited by 1,430
The Roles of Protein C and Thrombomodulin in the Regulation of Blood Coagulation
Esmon, C. T. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)83649-3 · Cited by 1,046
Factor XI Activation in a Revised Model of Blood Coagulation
Gailani, D., & Broze, G. J. (1991) · Science · doi:10.1126/science.1652157 · Cited by 775 · cited 3×
“Both in vitro (Gerotziafas et al, 2004b; Gatt et al, 2006) and limited ex vivo and clinical experience (Bijsterveld et al, 2002; Huvers et al, 2005) point to the beneficial use of rFVIIa in reversing the anticoagulant effect of fondaparinux.”
BackgroundMethodBaglin, T., Luddington, R., Brown, K., & Baglin, C. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14111-6 · Cited by 694 · cited 1×
“After a first idiopathic event, treatment with anticoagulation is often discontinued after 6 months even though up to 19% of patients are reported to have a recurrence in the following 2 years (Baglin et al, 2003).”
BackgroundThrombelastography/thromboelastometry
LUDDINGTON, R. J. (2005) · Clinical and Laboratory Haematology · doi:10.1111/j.1365-2257.2005.00681.x · Cited by 655
Thrombophilia, Clinical Factors, and Recurrent Venous Thrombotic Events
Christiansen, S. C. (2005) · JAMA · doi:10.1001/jama.293.19.2352 · Cited by 586
Platelet activity of high‐dose factor VIIa is independent of tissue factor
Monroe, D. M., Hoffman, M., Oliver, J. A., & Roberts, H. R. (1997) · British Journal of Haematology · doi:10.1046/j.1365-2141.1997.4463256.x · Cited by 534 · cited 1×
“Several studies examined the effect of recombinant (r)FVIIa on thrombin generation in different settings (Monroe et al, 1997; Kjalke et al, 2001; Butenas et al, 2002; Gerotziafas et al, 2002, 2004a,b; Turecek et al, 2003; Wegert et al, 2005; Allen et al, 2006; Livnat et al, 2006; van Veen et al,…”
BackgroundMakris, M., Greaves, M., Phillips, W. S., Kitchen, S., Rosendaal, F. R., & Preston, F. E. (1997) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1655992 · Cited by 401 · cited 1×
“We showed that despite normalization of the INR with FFP in most over-anticoagulated patients, FIX concentration is suboptimal when compared with the use of prothrombin complex concentrates (PCCs) (Makris et al, 1997).”
BackgroundSelf-citationBlood clotting in minimally altered whole blood
Rand, M., Lock, J., van't Veer, C., Gaffney, D., & Mann, K. (1996) · Blood · doi:10.1182/blood.v88.9.3432.bloodjournal8893432 · Cited by 400 · cited 1×
“These tests use clot formation as their endpoint, which occurs when only around 5% of all physiologically relevant thrombin is formed (Hemker & Beguin, 1995; Rand et al, 1996) and also are insensitive to prothrombotic states.”
Method
Cited by
Thrombin Generation Assay and Its Application in the Clinical Laboratory
Tripodi, A. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.248625 · Cited by 318
Biomarkers for prediction of venous thromboembolism in cancer
Pabinger, I., Thaler, J., & Ay, C. (2013) · Blood · doi:10.1182/blood-2013-04-460147 · Cited by 256
Diagnosis and treatment of factor VIII and IX inhibitors in congenital haemophilia: (4th edition)
Collins, P. W., Chalmers, E., Hart, D. P., Liesner, R., Rangarajan, S., Talks, K., Williams, M., & Hay, C. R. (2013) · British Journal of Haematology · doi:10.1111/bjh.12091 · Cited by 213
“These tests are not standardized in terms of reagents and technique and therefore the results cannot be compared (Dargaud et al, 2007; Lewis et al, 2007; van Veen et al, 2008).”
BackgroundEnhanced thrombin generation in patients with cirrhosis‐induced coagulopathy
GATT, A., RIDDELL, A., CALVARUSO, V., TUDDENHAM, E. G., MAKRIS, M., & BURROUGHS, A. K. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.03937.x · Cited by 202
Self-citationThrombin generation: What have we learned?
Al Dieri, R., de Laat, B., & Hemker, H. C. (2012) · Blood Reviews · doi:10.1016/j.blre.2012.06.001 · Cited by 177
Castoldi, E., & Rosing, J. (2011) · Thrombosis Research · doi:10.1016/s0049-3848(11)70007-x · Cited by 175
Laboratory assessment of new anticoagulants
Samama, M. M., & Guinet, C. (2011) · cclm · doi:10.1515/cclm.2011.134 · Cited by 174
“Many tests measuring thrombin generation exist, but they are not standardized (57).”
BackgroundAssays for Measuring Rivaroxaban: Their Suitability and Limitations
Lindhoff-Last, E., Samama, M. M., Ortel, T. L., Weitz, J. I., & Spiro, T. E. (2010) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e3181f2f264 · Cited by 159
“Because there is no standardization of the methods, the different assay systems generate different results.(43,44) The main measurement parameters include: the maximum concentration of thrombin (peak), the endogenous thrombin potential (ETP; which represent thrombin activity multiplied by the time for which it remains…”
MethodBiomarkers and Venous Thromboembolism
Pabinger, I., & Ay, C. (2009) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.108.182188 · Cited by 158
Metadata
- Authors
- Van Veen, J. J., Gatt, A., & Makris, M.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 2008-08-21
- Volume
- 142
- Issue
- 6
- Pages
- 889-903
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W2000305246
- Cited by
- 209
- References
- 54
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.