Quantitative imaging of green fluorescent protein in cultured cells: Comparison of microscopic techniques, use in fusion proteins and detection limits
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Summary: To determine the application limits of green fluorescent protein (GFP) as a reporter gene or protein tag, we expressed GFP by itself and with fusion protein partners, and used three different imaging methods to identify GFP fluorescence. In conventional epifluorescence photomicroscopy, GFP expressed in cells could be distinguished as a bright green signal over a yellow‐green autofluorescence background. In quantitative fluorescence microscopy, however, the GFP signal is contaminated by cellular autofluorescence. Improved separation of GFP signal from HeLa cell autofluorescence was achieved by the combination of confocal scanning laser microscopy using 488‐nm excitation, a rapid cut‐on dichroic mirror and a narrow‐bandpass emission filter. Two‐photon excitation of GFP fluorescence at the equivalent of ≅ 390 nm provided better absorption than did 488‐nm excitation. This resulted in increased signal/background but also generated a different autofluorescence pattern and appeared to increase GFP photobleaching. Fluorescence spectra similar to those of GFP alone were observed when GFP was expressed as a fusion protein either with glutathione‐S‐transferase (GST) or with glucokinase. Furthermore, purified GST•GFP fusion protein displayed an extinction coefficient and quantum yield consistent with values previously reported for GFP alone. In HeLa cells, the cytoplasmic GFP concentration must be greater than ≅ 1 μM to allow quantifiable discrimination over autofluorescence. However, lower expression levels may be detectable if GFP is targeted to discrete subcellular compartments, such as the plasma membrane, organelles or nucleus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Green fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802
Smith, D. B., & Johnson, K. S. (1988) · Gene · doi:10.1016/0378-1119(88)90005-4 · Cited by 5,892
Wavelength mutations and posttranslational autoxidation of green fluorescent protein.
Heim, R., Prasher, D. C., & Tsien, R. Y. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.26.12501 · Cited by 1,810
Heim, R., Cubitt, A. B., & Tsien, R. Y. (1995) · Nature · doi:10.1038/373663b0 · Cited by 1,782
Andersson, S., Davis, D. L., Dahlbäck, H., Jörnvall, H., & Russell, D. W. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)83172-6 · Cited by 1,229
Autofluorescence of viable cultured mammalian cells.
Aubin, J. E. (1979) · Journal of Histochemistry & Cytochemistry · doi:10.1177/27.1.220325 · Cited by 555
Wang, S., & Hazelrigg, T. (1994) · Nature · doi:10.1038/369400a0 · Cited by 478
Intermolecular energy transfer in the bioluminescent system of Aequorea
Morise, H., Shimomura, O., Johnson, F. H., & Winant, J. (1974) · Biochemistry · doi:10.1021/bi00709a028 · Cited by 452
Structure and Function of Cyclic Nucleotide-Dependent Protein Kinases
Francis, S. H., & Corbin, J. D. (1994) · Annual Review of Physiology · doi:10.1146/annurev.ph.56.030194.001321 · Cited by 440
Cited by
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Development of a self-inactivating lentivirus vector
Miyoshi, H., Blömer, U., Takahashi, M., Gage, F. H., & Verma, I. M. (1998) · Journal of Virology · doi:10.1128/jvi.72.10.8150-8157.1998 · Cited by 1,196
Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165
Two-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
CREB: A Major Mediator of Neuronal Neurotrophin Responses
Finkbeiner, S., Tavazoie, S. F., Maloratsky, A., Jacobs, K. M., Harris, K. M., & Greenberg, M. E. (1997) · Neuron · doi:10.1016/s0896-6273(00)80395-5 · Cited by 949
Adams, S. R., Campbell, R. E., Gross, L. A., Martin, B. R., Walkup, G. K., Yao, Y., Llopis, J., & Tsien, R. Y. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017687n · Cited by 927
Use of the green fluorescent protein and its mutants in quantitative fluorescence microscopy
Patterson, G. H., Knobel, S. M., Sharif, W. D., Kain, S. R., & Piston, D. W. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78307-3 · Cited by 850
Self-citationEllenberg, J., Siggia, E. D., Moreira, J. E., Smith, C. L., Presley, J. F., Worman, H. J., & Lippincott-Schwartz, J. (1997) · The Journal of Cell Biology · doi:10.1083/jcb.138.6.1193 · Cited by 768
Zlokarnik, G., Negulescu, P. A., Knapp, T. E., Mere, L., Burres, N., Feng, L., Whitney, M., Roemer, K., & Tsien, R. Y. (1998) · Science · doi:10.1126/science.279.5347.84 · Cited by 690
Photon Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 676
The regulation and function of Class III PI3Ks: novel roles for Vps34
Backer, J. M. (2008) · Biochemical Journal · doi:10.1042/bj20071427 · Cited by 659
Attenuation of green fluorescent protein half-life in mammalian cells
Corish, P., & Tyler-Smith, C. (1999) · Protein Engineering, Design and Selection · doi:10.1093/protein/12.12.1035 · Cited by 559
High-Resolution Nonlinear Optical Imaging of Live Cells by Second Harmonic Generation
Campagnola, P. J., Wei, M.-D., Lewis, A., & Loew, L. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77165-1 · Cited by 504
Billinton, N., & Knight, A. W. (2001) · Analytical Biochemistry · doi:10.1006/abio.2000.5006 · Cited by 499
Live Astrocytes Visualized by Green Fluorescent Protein in Transgenic Mice
Zhuo, L., Sun, B., Zhang, C.-L., Fine, A., Chiu, S.-Y., & Messing, A. (1997) · Developmental Biology · doi:10.1006/dbio.1997.8601 · Cited by 364
Second-harmonic imaging microscopy of living cells
Campagnola, P. J., Clark, H. A., Mohler, W. A., Lewis, A., & Loew, L. M. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1383294 · Cited by 244
Hanson, G. T., McAnaney, T. B., Park, E. S., Rendell, M. E. P., Yarbrough, D. K., Chu, S., Xi, L., Boxer, S. G., Montrose, M. H., & Remington, S. J. (2002) · Biochemistry · doi:10.1021/bi026609p · Cited by 238
Kain, S. R. (2005) · Methods of Biochemical Analysis · doi:10.1002/0471739499.oth1 · Cited by 227
Mitosis enhances transgene expression of plasmid delivered by cationic liposomes
Tseng, W.-C., Haselton, F. R., & Giorgio, T. D. (1999) · Biochimica et Biophysica Acta (BBA) - Gene Structure and Expression · doi:10.1016/s0167-4781(99)00039-1 · Cited by 221
Flow cytometric and microscopic analysis of GFP-tagged Pseudomonas fluorescens bacteria
Tombolini, R., Unge, A., Davey, M. E., Bruijn, F. J., & Jansson, J. K. (2006) · FEMS Microbiology Ecology · doi:10.1111/j.1574-6941.1997.tb00352.x · Cited by 211
Fluorophores for Confocal Microscopy: Photophysics and Photochemistry
Tsien, R. Y., Ernst, L., & Waggoner, A. (2006) · Handbook Of Biological Confocal Microscopy · doi:10.1007/978-0-387-45524-2_16 · Cited by 201
Tseng, W.-C., Haselton, F. R., & Giorgio, T. D. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.41.25641 · Cited by 182
Volkmer, A., Subramaniam, V., Birch, D. J. S., & Jovin, T. M. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76711-7 · Cited by 179
“When fused to proteins of interest and expressed in vivo, GFP acts as a versatile indicator of structure and function within cells (Misteli and Spector, 1997) and can be visualized using standard microscopy techniques (Niswender et al., 1995; Presley et al., 1997) and multiphoton excitation (MPE) microscopy (Kohler et…”
BackgroundFluorescent proteins: a cell biologist's user guide
Snapp, E. L. (2009) · Trends in Cell Biology · doi:10.1016/j.tcb.2009.08.002 · Cited by 171
Confocal Laser Scanning Microscopy
Paddock, S. W. (1999) · BioTechniques · doi:10.2144/99275ov01 · Cited by 167
Design and Use of Fluorescent Fusion Proteins in Cell Biology
Snapp, E. (2005) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb2104s27 · Cited by 166
“…2 Francis and Corbin, 1994 Calmodulin 30 Manalan and Klee, 1984 Cytoskeleton Actin 95 Luby-Phelps, 2000 Vimentin 3 Luby-Phelps, 2000 aAccording to Niswender et al. (1995) and Patterson et al. (1997), a concentration of at least 200 nM enhanced green fluorescent protein (EGFP) is necessary to…”
BackgroundIgnowski, J. M., & Schaffer, D. V. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20059 · Cited by 164
“…intrinsic fluorescence is readily visualized, and that it is nonenzymatic and thus does not require a substrate; however, considerable concentrations of this fluor ( c 1 AM) must be present inside the cell to detect a signal over the background noise (Cubitt et al., 1995; Niswender et al., 1995).”
Metadata
- Authors
- NISWENDER, K. D., BLACKMAN, S. M., ROHDE, L., MAGNUSON, M. A., & PISTON, D. W.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1995-11
- Volume
- 180
- Issue
- 2
- Pages
- 109-116
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2144259254
- Cited by
- 203
- References
- 25
- FWCI
- 11.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.