Photoplethysmography and nociception
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Photoplethysmography (PPG), i.e. pulse oximetric wave, is a non‐invasive technique that is used in anaesthesia monitoring primarily to monitor blood oxygenation. The PPG waveform resembles that of the arterial blood pressure but instead of pressure it is related to the volume changes in the measurement site and hence contains information related to the peripheral blood circulation, including skin vasomotion, which is controlled by the sympathetic nervous system. Because of this link, skin vasomotor response and PPG amplitude response have been associated with nociception under general anaesthesia. Recently, there has been interest in monitoring nociception during general anaesthesia. In many of the published studies, PPG waveform information has been included. The focus of this topical review is to provide an overview on the information embedded in the PPG waveform especially in the context of the autonomic nervous system and analgesia monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sympathovagal Balance: A Critical Appraisal
Eckberg, D. L. (1997) · Circulation · doi:10.1161/01.cir.96.9.3224 · Cited by 1,087
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
Seitsonen, E. R. J., Korhonen, I. K. J., Van Gils, M. J., Huiku, M., Lötjönen, J. M. P., Korttila, K. T., & Yli‐Hankala, A. M. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00654.x · Cited by 120 · cited 13×
“combined information from beatto-beat R-to-R interval (RRI), PPGn amplitude and EEG Response Entropy (RE)(37) and were able to discriminate movers and non-movers to skin incision during sevoflurane anaesthesia with 96% accuracy in 26 patients.(7) In their analysis, the RE,”
BackgroundMethodSelf-citationShelley, K. H., Tamai, D., Jablonka, D., Gesquiere, M., Stout, R. G., & Silverman, D. G. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000145063.01043.4b · Cited by 91 · cited 2×
“beneficial if the venous components of PPG variations are of interest,(2) and may also be applied to areas that are less affected by vasoconstriction.(14) In the study of ANS responses to nociception, however, the main interest is to use PPG to reflect”
Background
Cited by
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review
Almarshad, M. A., Islam, M. S., Al-Ahmadi, S., & BaHammam, A. S. (2022) · Healthcare · doi:10.3390/healthcare10030547 · Cited by 188
Pain Intensity Recognition Rates via Biopotential Feature Patterns with Support Vector Machines
Gruss, S., Treister, R., Werner, P., Traue, H. C., Crawcour, S., Andrade, A., & Walter, S. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140330 · Cited by 161
Metadata
- Authors
- KORHONEN, I., & YLI‐HANKALA, A.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 2009-08-07
- Volume
- 53
- Issue
- 8
- Pages
- 975-985
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2108921973
- Cited by
- 104
- References
- 5
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.