CoChat

ACUTE EFFECTS OF NICOTINE ON ARTERIAL STIFFNESS AND WAVE REFLECTION IN HEALTHY YOUNG NON‐SMOKERS

Adamopoulos, Dionysios, Argacha, Jean‐François, Gujic, Marko, Preumont, Nicolas, Degaute, Jean‐Paul, Van De Borne, Philippe · 2009 · Clinical and Experimental Pharmacology and Physiology
Cited by 45

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

SUMMARY: Recently, we have demonstrated that cigarette smoke exposure proportionally increases plasma nicotine levels and arterial wave reflection to the aorta. However, the exact contribution of nicotine to the smoke‐induced enhancement of wave reflection and the potential underlying mechanisms have not been fully investigated. The present study was a prospective study in 15 healthy male non‐smokers. All received a placebo and a 2 mg nicotine tablet, according to a randomized double‐blind cross‐over study design. Each subject underwent repeated measurements at baseline and for 1 h after nicotine or placebo intake, using carotid–femoral pulse wave velocity (PWV) to assess arterial compliance. Concurrently, aortic pressures and the augmentation index were evaluated using applanation tonometry. Plasma nicotine concentrations achieved 1 h after intake of the nicotine tablet reached comparable levels to those achieved after 1 h exposure to passive smoke (3.6 ± 0.4 vs 3.2 ± 0.4 ng/mL, respectively;P = 0.4). Nicotine enhanced arterial wave reflection to the aorta, as assessed by the augmentation index corrected for heart rate (4.2 ± 1.3 vs–0.7 ± 0.8% with placebo;P = 0.001). In addition, a progressive increase in carotid–femoral PWV was noted after nicotine administration (0.3 ± 0.1 vs–0.02 ± 0.1 m/s with placebo;P = 0.04). This remained significant even after adjustment for changes in mean blood pressure and heart rate (P = 0.01). Plasma nicotine concentrations comparable to those achieved after exposure to passive smoke enhance arterial wave reflection to the aorta. This is accompanied by an increase in carotid–femoral PWV, denoting a deterioration of arterial compliance by nicotine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1681.2009.05141.x

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 45

Metadata

Authors
Adamopoulos, D., Argacha, J., Gujic, M., Preumont, N., Degaute, J., & Van De Borne, P.
Venue
Clinical and Experimental Pharmacology and Physiology
Publisher
Wiley
Published
2009-07-28
Volume
36
Issue
8
Pages
784-789
ISSN
  • 0305-1870 (ISSN-L)
  • 1440-1681
OpenAlex
W2012422029
Cited by
45
References
9
FWCI
0.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.