Control of Blood Glucose in Diabetics using an Artificial Pancreas*
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Studies have been performed using an on-line computer system programmed for blood gucose control of insulin and dextrose infusion (artificial pancreas). The aim of these studies was to test performance of the artificial pancreas and to suggest directions for future optimisation. Blood glucose stabilisation studies of diabetic volunteers were extended throughout the day and included three main meals and light exercise periods. Monitoring of blood glucose profiles of the same diabetics after depot insulin were performed on a separate occasion for comparison. The presence of insulin antibodies did not impair operation of the artificial pancreas. Most of the insulin infused by the artificial pancreas was to initially correct hyperglycaemia with relatively little required to subsequently maintian euglycaemia. The afternoon intra-meal average infusion rate was 0-9 U/hr. It is suggested that correction of fasting hyperglycaemia and maintenance of euglycaemia in diabetics be treated as separate control problems for the artificial pancreas. The overall ability of the artificial pancreas to control blood glucose to a degree not attainable by conventional insulin therapy is confirmed, in this case under conditions which include patient activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Research works printed but not linked: 14
- Cahill, 1972, Practical developments in diabetes research, Diabetes, 21, 703, 10.2337/diab.21.2.S703 · doi:10.2337/diab.21.2.s703
- Albisser, 1974, Clinical control of diabetes by the artificial pancreas, Diabetes, 23, 397, 10.2337/diab.23.5.397 · DOI · Paper page
- Pfeiffer, 1974, The artificial beta cell-a continuous control of blood sugar by external regulation of insulin infusion (glucose-controlled insulin infusion system), Horm. Metab. Res., 6, 339, 10.1055/s-0028-1093841 · DOI · Paper page
- Kraegen, 1975, Clinical studies using an artificial endocrine pancreas, Aust. N.Z. J. Med., 5, 390
- Layne, 1976, Continuous extracorporeal monitoring of animal blood using the glucose electrode, Diabetes, 25, 81, 10.2337/diab.25.2.81 · doi:10.2337/diab.25.2.81
- Soeldner, 1973, In vitro and in vivo experience with a miniature glucose sensor, Diabetes, 22, 294
- Trinder, 1969, Determination of blood glucose using an oxidase-peroxidase system with a non-carcinogenic chromogen, J. clin. Path., 22, 158, 10.1136/jcp.22.2.158 · DOI · Paper page
- Kraegen, 1975, Carrier solutions for low-level insulin infusion, Brit. med. J., 3, 464, 10.1136/bmj.3.5981.464 · DOI · Paper page
- Kraegen, 1976, Proc. Ninth Cong. Intl. Diabetes Fed.
- Slama, 1974, One to five days of continuous intravenous insulin infusion on seven diabetic patients, Diabetes, 23, 732, 10.2337/diab.23.9.732 · DOI
- Turner, 1971, Measurement of insulin delivery rate in man, J. clin. Endocr., 33, 279, 10.1210/jcem-33-2-279 · DOI · Paper page
- Genuth, 1973, Plasma insulin and glucose profiles in normal obese and diabetic persons, Ann. intern. Med., 79, 812, 10.7326/0003-4819-79-6-812 · DOI · Paper page
- Kidson, 1974, The treatment of severe diabetic hyperglycaemia by insulin infusion, Brit. med. J., 2, 691, 10.1136/bmj.2.5921.691 · DOI · Paper page
- Campbell , L. V. Kraegen , E. W. Lazarus , L. Meler , H. Chia , Y. O. Chisholm , D. J. Alford , F. 1976 Defective hypoglycaemia counter-regulation during physiologic insulin infusion. Proc. Ninth Congress of Int. Diabetes Fed., Abstract 69, Excerpta Medica
Cited by
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Metadata
- Authors
- Kraegen, E. W., Campbell, L. V., Chia, Y. O., Meier, H., & Lazarus, L.
- Venue
- Australian and New Zealand Journal of Medicine
- Publisher
- Wiley
- Published
- 1977-06
- Volume
- 7
- Issue
- 3
- Pages
- 280-286
- ISSN
- 0004-8291 (ISSN-L)
- OpenAlex
- W2081557730
- Cited by
- 58
- References
- 1
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm, 13971 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control of Blood Glucose in Diabetics using an Artificial Pancreas*. https://app.cochat.ai/papers/10.1111/j.1445-5994.1977.tb03687.x
- The paper
- Kraegen, E. W., Campbell, L. V., Chia, Y. O., Meier, H., & Lazarus, L. (1977). Control of Blood Glucose in Diabetics using an Artificial Pancreas*. Australian and New Zealand Journal of Medicine. https://doi.org/10.1111/j.1445-5994.1977.tb03687.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.