Application of the Poincaré plot to heart rate variability: a new measure of functional status in heart failure
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Background: Conventional methods of quantifying heart rate variability using summary statistics have shown that decreased variability is associated with increased mortality in heart failure. However, many patients with heart failure have arrhythmias which make the ‘raw’ heart rate variability data less suitable for the use of summary statistical measures. Aims: To examine the clinical potential of a new measure of heart rate variability data, presented by the Poincare plot pattern, as an adjunct to the summary statistical measures of R‐R interval Methods: We used the Poincaré plot pattern to display beat‐to‐beat heart rate variability data from a group of 23 patients with heart failure and compared them with data collected from 20 healthy age‐matched control subjects. The data, which consisted of 2000 consecutive R‐R intervals, were gathered over 20–40 minutes while the subjects rested supine in a quiet darkened room. Results: The morphological classification scheme proposed reflected the functional status of patients in heart failure. There was a significant difference (chi‐square = 27.5, df = 6, ρ < 0.0001) in the different pattern types between patients with NYHA Class I and II compared to patients with NYHA Class III and IV. All healthy subjects displayed a ‘cluster’ type of pattern characterised by normally distributed data. Sixteen of the 23 patients in heart failure also produced data which were normally distributed but the remaining seven produced data which required careful filtering to make them suitable for analysis using summary statistics, but which could be analysed by the Poincare plot. Conclusions: The Poincaréot pattern is a semi‐quantitative tool which can be applied to the analysis of R‐R interval data. It has potential advantages in that it allows assessment of data which are grossly non‐Gaussian in distribution, and is a simple and easily implemented method which can be used in a clinical setting to augment the standard electrocardiogram to provide ‘real time’ visualisation of data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple mathematical models with very complicated dynamics
May, R. M. (1976) · Nature · doi:10.1038/261459a0 · Cited by 7,001
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Plasma Norepinephrine as a Guide to Prognosis in Patients with Chronic Congestive Heart Failure
Cohn, J. N., Levine, T. B., Olivari, M. T., Garberg, V., Lura, D., Francis, G. S., Simon, A. B., & Rector, T. (1984) · New England Journal of Medicine · doi:10.1056/nejm198409273111303 · Cited by 3,125
Francis, G. S., Benedict, C., Johnstone, D. E., Kirlin, P. C., Nicklas, J., Liang, C. S., Kubo, S. H., Rudin-Toretsky, E., & Yusuf, S. (1990) · Circulation · doi:10.1161/01.cir.82.5.1724 · Cited by 1,388
Packer, M. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90167-l · Cited by 1,056
Hasking, G. J., Esler, M. D., Jennings, G. L., Burton, D., Johns, J. A., & Korner, P. I. (1986) · Circulation · doi:10.1161/01.cir.73.4.615 · Cited by 1,028
Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjects.
Hayano, J., Sakakibara, Y., Yamada, A., Yamada, M., Mukai, S., Fujinami, T., Yokoyama, K., Watanabe, Y., & Takata, K. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90445-q · Cited by 746
Saul, J. P., Arai, Y., Berger, R. D., Lilly, L. S., Colucci, W. S., & Cohen, R. J. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91172-1 · Cited by 706
The Neurohumoral Axis in Congestive Heart Failure
FRANCIS, G. S., GOLDSMITH, S. R., LEVINE, T. B., OLIVARI, M. T., & COHN, J. N. (1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-101-3-370 · Cited by 600
Components of heart rate variability — what they really mean and what we really measure
Malik, M., & Camm, A. J. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)91070-x · Cited by 575
Bigger, J. T., Fleiss, J. L., Rolnitzky, L. M., & Steinman, R. C. (1993) · Circulation · doi:10.1161/01.cir.88.3.927 · Cited by 500
Sinus Arrhythmia in Acute Myocardial Infarction
Wolf, M. M., Varigos, G. A., Hunt, D., & Sloman, J. G. (1978) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1978.tb131339.x · Cited by 486
O'Brien, I. A., O'Hare, P., & Corrall, R. J. (1986) · Heart · doi:10.1136/hrt.55.4.348 · Cited by 483
Patterns of beat-to-beat heart rate variability in advanced heart failure
Woo, M. A., Stevenson, W. G., Moser, D. K., Trelease, R. B., & Harper, R. M. (1992) · American Heart Journal · doi:10.1016/0002-8703(92)90510-3 · Cited by 429
MALIK, M., FARRELL, T., CRIPPS, T., & CAMM, A. J. (1989) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a059428 · Cited by 387
Time Domain Measurements of Heart Rate Variability
Kleiger, R. E., Stein, P. K., Bosner, M. S., & Rottman, J. N. (1992) · Cardiology Clinics · doi:10.1016/s0733-8651(18)30230-3 · Cited by 383
Is the normal heart a periodic oscillator?
Babloyantz, A., & Destexhe, A. (1988) · Biological Cybernetics · doi:10.1007/bf00364139 · Cited by 369
Cardiac vagal efferent activity and heart period in the carotid sinus reflex
Katona, P., Poitras, J., Barnett, G., & Terry, B. (1970) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1970.218.4.1030 · Cited by 341
Ferguson, D. W., Berg, W. J., Sanders, J. S., & Kempf, J. S. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90544-y · Cited by 269
Kienzle, M. G., Ferguson, D. W., Birkett, C. L., Myers, G. A., Berg, W. J., & Mariano, D. J. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90502-p · Cited by 249
Fascinating rhythm: A primer on chaos theory and its application to cardiology
Denton, T. A., Diamond, G. A., Helfant, R. H., Khan, S., & Karagueuzian, H. (1990) · American Heart Journal · doi:10.1016/0002-8703(90)90258-y · Cited by 247
Autonomic pathophysiology in heart failure patients. Sympathetic-cholinergic interrelations.
Porter, T. R., Eckberg, D. L., Fritsch, J. M., Rea, R. F., Beightol, L. A., Schmedtje, J. F., & Mohanty, P. K. (1990) · Journal of Clinical Investigation · doi:10.1172/jci114580 · Cited by 213
Effects of heart failure on baroreflex control of sympathetic neural activity
Ferguson, D. W., Berg, W. J., Roach, P. J., Oren, R. M., & Mark, A. L. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90998-e · Cited by 211
Low heart rate variability and sudden cardiac death
Singer, D. H., Martin, G. J., Magid, N., Weiss, J. S., Schaad, J. W., Kehoe, R., Zheutlin, T., Fintel, D. J., Hsieh, A.-M., & Lesch, M. (1988) · Journal of Electrocardiology · doi:10.1016/0022-0736(88)90055-6 · Cited by 187
Noradrenaline Release And Sympathetic Nervous System Activity
Esler, M. D., Hasking, G. J., Willett, I. R., Leonard, P. W., & Jennings, G. L. (1985) · Journal of Hypertension · doi:10.1097/00004872-198504000-00003 · Cited by 165
Bigger, J. T., Albrecht, P., Steinman, R. C., Rolnitzky, L. M., Fleiss, J. L., & Cohen, R. J. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)90436-0 · Cited by 153
Circadian variation of heart rate variability
Malpas, S. C., & Purdie, G. L. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.3.210 · Cited by 129
Nonlinear dynamics, fractals and chaos: Applications to cardiac electrophysiology
Goldberger, A. L. (1990) · Annals of Biomedical Engineering · doi:10.1007/bf02368429 · Cited by 109
Prognostic Value of Heart Rate Variability in Patients Awaiting Cardiac Transplantation
BINDER, T., FREY, B., PORENTA, G., HEINZ, G., WUTTE, M., KREINER, G., GÖSSINGER, H., SCHMIDINGER, H., PACKER, R., & WEBER, H. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb03050.x · Cited by 98
Flapan, A. D., Nolan, J., Neilson, J. M. M., & Ewing, D. J. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90999-f · Cited by 93
Dynamic vagal control of pacemaker activity in the mammalian sinoatrial node.
Jalife, J., Slenter, V. A., Salata, J. J., & Michaels, D. C. (1983) · Circulation Research · doi:10.1161/01.res.52.6.642 · Cited by 90
MICHAELS, D. C., Matyas, E. P., & Jalife, J. (1986) · Circulation Research · doi:10.1161/01.res.58.5.706 · Cited by 90
Jalife, J., & Moe, G. K. (1979) · Circulation Research · doi:10.1161/01.res.45.5.595 · Cited by 85
Failure of plasma norepinephrine to consistently reflect sympathetic activity in humans.
Floras, J., Vann Jones, J., Hassan, M. O., Osikowska, B. A., Sever, P. S., & Sleight, P. (1986) · Hypertension · doi:10.1161/01.hyp.8.8.641 · Cited by 75
Dynamic Characteristics of Cardiac R-R Intervals during Sleep and Waking States
Raetz, S. L., Richard, C. A., Garfinkel, A., & Harper, R. M. (1991) · Sleep · doi:10.1093/sleep/14.6.526 · Cited by 58
Heart rate behaviour at different stages of congestive heart failure
Stefenelli, T., Bergler-Klein, J. K., Globits, S., Pacher, R., & Glogar, D. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060290 · Cited by 36
Phasic effects of repetitive vagal stimulation on atrial contraction.
Martin, P. J., Levy, J. R., Wexberg, S., & Levy, M. N. (1983) · Circulation Research · doi:10.1161/01.res.52.6.657 · Cited by 9
Cited by
Sleep loss: a novel risk factor for insulin resistance and type 2 diabetes
Spiegel, K., Knutson, K., Leproult, R., Tasali, E., & Cauter, E. V. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00660.2005 · Cited by 1,175
Do existing measures of Poincaré plot geometry reflect nonlinear features of heart rate variability
Brennan, M., Palaniswami, M., & Kamen, P. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.959330 · Cited by 1,044
Self-citationvon Borell, E., Langbein, J., Després, G., Hansen, S., Leterrier, C., Marchant, J., Marchant-Forde, R., Minero, M., Mohr, E., Prunier, A., et al. (2007) · Physiology & Behavior · doi:10.1016/j.physbeh.2007.01.007 · Cited by 974
Methods derived from nonlinear dynamics for analysing heart rate variability
Voss, A., Schulz, S., Schroeder, R., Baumert, M., & Caminal, P. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2008.0232 · Cited by 590
Support Vector Machines for Automated Gait Classification
Begg, R. K., Palaniswami, M., & Owen, B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845241 · Cited by 408
Metadata
- Authors
- Kamen, P. W., & Tonkin, A. M.
- Venue
- Australian and New Zealand Journal of Medicine
- Publisher
- Wiley
- Published
- 1995-02
- Volume
- 25
- Issue
- 1
- Pages
- 18-26
- ISSN
- 0004-8291 (ISSN-L)
- OpenAlex
- W2048811598
- Cited by
- 202
- References
- 38
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.