Application and use of various mass spectrometry methods in clinical microbiology
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sequencing technologies – the next generation
Metzker, M. L. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2626 · Cited by 7,066 · cited 1×
“The interested reader is invited to refer to Metzker’s article [43] for an updated review on next-generation sequencing, to Maiden’s [44] for the description of MLST, and to Palacios’s [45] for the use of high-throughput sequencing for identification of microbial sequences not found by any other method available.”
BackgroundMaiden, M. C. J., Bygraves, J. A., Feil, E., Morelli, G., Russell, J. E., Urwin, R., Zhang, Q., Zhou, J., Zurth, K., Caugant, D. A., et al. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.6.3140 · Cited by 3,833 · cited 1×
“The interested reader is invited to refer to Metzker’s article [43] for an updated review on next-generation sequencing, to Maiden’s [44] for the description of MLST, and to Palacios’s [45] for the use of high-throughput sequencing for identification of microbial sequences not found by any other method available.”
BackgroundSeng, P., Drancourt, M., Gouriet, F., La Scola, B., Fournier, P., Rolain, J. M., & Raoult, D. (2009) · Clinical Infectious Diseases · doi:10.1086/600885 · Cited by 1,983 · cited 3×
“As confirmed in other studies [2,14], the accuracy of bacterial identification was excellent, with high-confidence identifications for 94% (Bruker) and 88% (Shimadzu) of the 720 isolates analysed.”
BackgroundResultA New Arenavirus in a Cluster of Fatal Transplant-Associated Diseases
Palacios, G., Druce, J., Du, L., Tran, T., Birch, C., Briese, T., Conlan, S., Quan, P.-L., Hui, J., Marshall, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa073785 · Cited by 696 · cited 1×
“The interested reader is invited to refer to Metzker’s article [43] for an updated review on next-generation sequencing, to Maiden’s [44] for the description of MLST, and to Palacios’s [45] for the use of high-throughput sequencing for identification of microbial sequences not found by any other method available.”
Backgroundvan Veen, S. Q., Claas, E. C. J., & Kuijper, E. J. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.02071-09 · Cited by 667 · cited 3×
“As confirmed in other studies [2,14], the accuracy of bacterial identification was excellent, with high-confidence identifications for 94% (Bruker) and 88% (Shimadzu) of the 720 isolates analysed.”
BackgroundResultHolland, R. D., Wilkes, J. G., Rafii, F., Sutherland, J. B., Persons, C. C., Voorhees, K. J., & Lay, Jr. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960731)10:10<1227::aid-rcm659>3.0.co;2-6 · Cited by 637 · cited 1×
“This was more suitable for a microbiology laboratory, and by the mid-1990s MALDI-TOF MS was being used for the identification of bacteria in research settings [10,11].”
MethodBizzini, A., Durussel, C., Bille, J., Greub, G., & Prod'hom, G. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.01794-09 · Cited by 615 · cited 1×
“This has been confirmed not only in research settings, but also in routine diagnostic laboratories [2,14,24–26].”
BackgroundThe rapid identification of intact microorganisms using mass spectrometry
Claydon, M. A., Davey, S. N., Edwards-Jones, V., & Gordon, D. B. (1996) · Nature Biotechnology · doi:10.1038/nbt1196-1584 · Cited by 609 · cited 1×
“This was more suitable for a microbiology laboratory, and by the mid-1990s MALDI-TOF MS was being used for the identification of bacteria in research settings [10,11].”
MethodCherkaoui, A., Hibbs, J., Emonet, S., Tangomo, M., Girard, M., Francois, P., & Schrenzel, J. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.01881-09 · Cited by 527 · cited 2×
“Both devices (Bruker and Shimadzu), with their respective software and databases, have been tested in our laboratory [25].”
BackgroundMethodSelf-citationBizzini, A., & Greub, G. (2010) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2010.03311.x · Cited by 526
Cited by
MALDI-TOF mass spectrometry: an emerging technology for microbial identification and diagnosis
Singhal, N., Kumar, M., Kanaujia, P. K., & Virdi, J. S. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2015.00791 · Cited by 1,605
Applications of MALDI-TOF mass spectrometry in clinical diagnostic microbiology
Croxatto, A., Prod'hom, G., & Greub, G. (2012) · FEMS Microbiology Reviews · doi:10.1111/j.1574-6976.2011.00298.x · Cited by 997
Clark, A. E., Kaleta, E. J., Arora, A., & Wolk, D. M. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00072-12 · Cited by 941
Klebsiella variicola : an emerging pathogen in humans
Rodríguez-Medina, N., Barrios-Camacho, H., Duran-Bedolla, J., & Garza-Ramos, U. (2019) · Emerging Microbes & Infections · doi:10.1080/22221751.2019.1634981 · Cited by 248
“MALDI-TOF MS is a fast and cost-effective technique [41,42], while the Bruker microorganism reference library version 4.”
MethodMALDI-TOF Mass Spectrometry for Microorganism Identification
Dingle, T. C., & Butler-Wu, S. M. (2013) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2013.03.001 · Cited by 243
Use of MALDI-TOF mass spectrometry for identification of bacteria that are difficult to culture
Biswas, S., & Rolain, J.-M. (2013) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2012.10.014 · Cited by 212
Rahi, P., Prakash, O., & Shouche, Y. S. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.01359 · Cited by 191
“…Rahi praveen_rahi22@yahoo.co.in; praveen@nccs.res.in Specialty section: This article was submitted to Microbial Physiology and Metabolism, a section of the journal Frontiers in Microbiology Received: 28 January 2016 Accepted: 17 August 2016 Published: 30 August 2016 Citation:”
BackgroundMethodProteomics for routine identification of microorganisms
Welker, M. (2011) · PROTEOMICS · doi:10.1002/pmic.201100049 · Cited by 175
“Although other MS techniques have been applied for the purpose of microbial identification and characterization, such as LC-QTOF-MS, primarily MALDI-TOF-MS eventually was adopted for routine diagnostics [3, 29].”
BackgroundMethodSanguinetti, M., & Posteraro, B. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.01640-16 · Cited by 154
“, an open database made by AnagnosTec) with its own closed database (7).”
Background
Metadata
- Authors
- Emonet, S., Shah, H. N., Cherkaoui, A., & Schrenzel, J.
- Venue
- Clinical Microbiology and Infection
- Publisher
- Elsevier BV
- Published
- 2010-11
- Volume
- 16
- Issue
- 11
- Pages
- 1604-1613
- ISSN
- 1198-743X (ISSN-L)
- OpenAlex
- W1839847945
- Cited by
- 159
- References
- 38
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.