CoChat

Control of pulsatile 5‐HT/insulin secretion from single mouse pancreatic islets by intracellular calcium dynamics

Open access
Barbosa, Rui M., Silva, Amélia M., Tomé, Angelo R., Stamford, Jonathan A., Santos, Rosa M., Rosário, Luís M. · 1998 · The Journal of Physiology
Cited by 113

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Glucose‐induced insulin release from single islets of Langerhans is pulsatile. We have investigated the correlation between changes in cytosolic free calcium concentration ([Ca 2+]i) and oscillatory insulin secretion from single mouse islets, in particular examining the basis for differences in secretory responses to intermediate and high glucose concentrations. Insulin release was monitored in real time through the amperometric detection of the surrogate insulin marker 5‐hydroxytryptamine (5‐HT) via carbon fibre microelectrodes. The [Ca 2+]i was simultaneously recorded by whole‐islet fura‐2 microfluorometry. In 82 % of the experiments, exposure to 11 mM glucose evoked regular high‐frequency (average, 3.4 min−1) synchronous oscillations in amperometric current and [Ca 2+]i. In the remaining experiments (18 %), 11 mM glucose induced an oscillatory pattern consisting of high‐frequency [Ca 2+]i oscillations that were superimposed on low‐frequency (average, 0.32 min−1) [Ca 2+]i waves. Intermittent high‐frequency [Ca 2+]i oscillations gave rise to a similar pattern of pulsatile 5‐HT release. Raising the glucose concentration from 11 to 20 mM increased the duration of the steady‐state [Ca 2+]i oscillations without increasing their amplitude. In contrast, both the duration and amplitude of the associated 5‐HT transients were increased by glucose stimulation. The amount of 5‐HT released per secretion cycle was linearly related to the duration of the underlying [Ca 2+]i oscillations in both 11 and 20 mM glucose. The slopes of the straight lines were identical, indicating that there is no significant difference between the ability of calcium oscillations to elicit 5‐HT/insulin release in 11 and 20 mM glucose. In situ 5‐HT microamperometry has the potential to resolve the high‐frequency oscillatory component of the second phase of glucose‐induced insulin secretion. This component appears to reflect primarily the duration of the underlying [Ca 2+]i oscillations, suggesting that glucose metabolism and/or access to glucose metabolites is not rate limiting to fast pulsatile insulin release.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7793.1998.135bz.x

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 113

Metadata

Authors
Barbosa, R. M., Silva, A. M., Tomé, A. R., Stamford, J. A., Santos, R. M., & Rosário, L. M.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1998-07
Volume
510
Issue
1
Pages
135-143
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2130258021
Cited by
113
References
11
FWCI
5.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control of pulsatile 5‐HT/insulin secretion from single mouse pancreatic islets by intracellular calcium dynamics. https://app.cochat.ai/papers/10.1111/j.1469-7793.1998.135bz.x
The paper
Barbosa, R. M., Silva, A. M., Tomé, A. R., Stamford, J. A., Santos, R. M., & Rosário, L. M. (1998). Control of pulsatile 5‐HT/insulin secretion from single mouse pancreatic islets by intracellular calcium dynamics. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1998.135bz.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.