Mechanical properties of various mammalian tendons
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Dynamic tensile tests have been performed, using physiologically relevant frequencies and stress ranges, on various tendons from the legs and tails of 10 species of mammal. No consistent differences were found between tendons from different species or different anatomical sites. Tangent Young's modulus increases from low values at low stresses to about 1·5 GPa at stresses exceeding 30 MPa. Percentage energy dissipations of 6 to 11% have been measured for different species, but the lower values are probably the most reliable. There is little or no dependence of modulus or energy dissipation on frequency, in the range 0·2–11 Hz. The tensile strength of tendon (at strain rates of the order of 0·05 s−1) is at least 100 MPa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Collagen; ultrastructure and its relation to mechanical properties as a function of ageing
Diamant, J., Keller, A., Baer, E., Litt, M., & Arridge, R. G. C. (1972) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1972.0019 · Cited by 553
The mechanics of hopping by kangaroos (Macropodidae)
Alexander, R. M., & Vernon, A. (1975) · Journal of Zoology · doi:10.1111/j.1469-7998.1975.tb05983.x · Cited by 536
Self-citationThe Mechanical Properties of Rat Tail Tendon
Rigby, B. J., Hirai, N., Spikes, J. D., & Eyring, H. (1959) · The Journal of General Physiology · doi:10.1085/jgp.43.2.265 · Cited by 482
Elastic Energy Stores in Running Vertebrates
ALEXANDER, R. M. (1984) · American Zoologist · doi:10.1093/icb/24.1.85 · Cited by 411
Self-citationDynamic Tensile Properties of the Plantaris Tendon of Sheep (Ovis Aries)
Ker, R. F. (1981) · Journal of Experimental Biology · doi:10.1242/jeb.93.1.283 · Cited by 345
Self-citationWoo, S. L.-Y., Ritter, M. A., Amiel, D., Sanders, T. M., Gomez, M. A., Kuei, S. C., Garfin, S. R., & Akeson, W. H. (1980) · Connective Tissue Research · doi:10.3109/03008208009152109 · Cited by 338
The role of tendon elasticity in the locomotion of the camel (Camelus dromedarius)
Alexander, R. M., Maloiy, G. M. O., Ker, R. F., Jayes, A. S., & Warui, C. N. (1982) · Journal of Zoology · doi:10.1111/j.1469-7998.1982.tb02077.x · Cited by 229
Self-citationThe mechanics of jumping by a dog (Canis familiaris)
Alexander, R. M. (1974) · Journal of Zoology · doi:10.1111/j.1469-7998.1974.tb04134.x · Cited by 211
Self-citationThe role of tendon elasticity in hopping in a wallaby (Macropus rufogriseus)
Ker, R. F., Dimery, N. J., & Alexander, R. M. (1986) · Journal of Zoology · doi:10.1111/j.1469-7998.1986.tb01904.x · Cited by 186
Self-citationElastic properties of the cat soleus tendon and their functional importance.
Rack, P. M., & Westbury, D. R. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015077 · Cited by 184
Cited by
Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading
KJÆR, M. (2004) · Physiological Reviews · doi:10.1152/physrev.00031.2003 · Cited by 1,586
In vivo behaviour of human muscle tendon during walking
Fukunaga, T., Kubo, K., Kawakami, Y., Fukashiro, S., Kanehisa, H., & Maganaris, C. N. (2001) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.2000.1361 · Cited by 589
The origin and use of positional frames of reference in motor control
Feldman, A. G., & Levin, M. F. (1995) · Behavioral and Brain Sciences · doi:10.1017/s0140525x0004070x · Cited by 585
Biomechanics of Mammalian Terrestrial Locomotion
Biewener, A. A. (1990) · Science · doi:10.1126/science.2251499 · Cited by 582
Energy-Saving Mechanisms in Walking and Running
Alexander, R. M. (1991) · Journal of Experimental Biology · doi:10.1242/jeb.160.1.55 · Cited by 539
Self-citationHoy, M. G., Zajac, F. E., & Gordon, M. E. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90349-8 · Cited by 525
Joint stiffness: Myth or reality?
Latash, M. L., & Zatsiorsky, V. M. (1993) · Human Movement Science · doi:10.1016/0167-9457(93)90010-m · Cited by 522
In vivo human tendon mechanical properties
Maganaris, C. N., & Paul, J. P. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.00307.x · Cited by 494
Effect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.035576 · Cited by 484
Effect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1111/j..2003.t01-1-00971.x · Cited by 484
Load‐displacement properties of the human triceps surae aponeurosis in vivo
Magnusson, S. P., Aagaard, P., Rosager, S., Dyhre‐Poulsen, P., & Kjaer, M. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0277j.x · Cited by 407
Bone repair in the twenty–first century: biology, chemistry or engineering?
Hing, K. A. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2004.1466 · Cited by 400
Hill-Based Muscle Models: A Systems Engineering Perspective
Winters, J. M. (1990) · Multiple Muscle Systems · doi:10.1007/978-1-4613-9030-5_5 · Cited by 386
Why are mammalian tendons so thick?
KER, R. F., ALEXANDER, R. M., & BENNETT, M. B. (1988) · Journal of Zoology · doi:10.1111/j.1469-7998.1988.tb02432.x · Cited by 377
Self-citationElastic energy storage in tendons: mechanical differences related to function and age
Shadwick, R. E. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1033 · Cited by 362
Tendon elasticity and muscle function
McNeill Alexander, R. (2002) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/s1095-6433(02)00143-5 · Cited by 355
The Pathomechanics of Plantar Fasciitis
Wearing, S. C., Smeathers, J. E., Urry, S. R., Hennig, E. M., & Hills, A. P. (2006) · Sports Medicine · doi:10.2165/00007256-200636070-00004 · Cited by 345
The mechanical properties of natural materials. I. Material property charts
Ashby, M. F., Gibson, L. J., Wegst, U., & Olive, R. (1995) · Proceedings of the Royal Society of London. Series A: Mathematical and Physical Sciences · doi:10.1098/rspa.1995.0075 · Cited by 339
Rosager, S., Aagaard, P., Dyhre‐Poulsen, P., Neergaard, K., Kjaer, M., & Magnusson, S. P. (2002) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2002.120205.x · Cited by 317
Tensile properties of the in vivo human gastrocnemius tendon
Maganaris, C. N., & Paul, J. P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00240-3 · Cited by 305
Elastic energy storage in the shoulder and the evolution of high-speed throwing in Homo
Roach, N. T., Venkadesan, M., Rainbow, M. J., & Lieberman, D. E. (2013) · Nature · doi:10.1038/nature12267 · Cited by 304
Novel System for Engineering Bioartificial Tendons and Application of Mechanical Load
Garvin, J., Qi, J., Maloney, M., & Banes, A. J. (2003) · Tissue Engineering · doi:10.1089/107632703322495619 · Cited by 303
Muscle-tendon stresses and elastic energy storage during locomotion in the horse
Biewener, A. A. (1998) · Comparative Biochemistry and Physiology Part B: Biochemistry and Molecular Biology · doi:10.1016/s0305-0491(98)00024-8 · Cited by 282
The integrated function of muscles and tendons during locomotion
Roberts, T. J. (2002) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/s1095-6433(02)00244-1 · Cited by 272
Mechanical properties of tendon and aponeurosis of human gastrocnemius muscle in vivo
Muramatsu, T., Muraoka, T., Takeshita, D., Kawakami, Y., Hirano, Y., & Fukunaga, T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.5.1671 · Cited by 262
Is Achilles tendon compliance optimised for maximum muscle efficiency during locomotion?
Lichtwark, G. A., & Wilson, A. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.07.025 · Cited by 248
In Vivo Muscle Force–Length Behavior During Steady-Speed Hopping in Tammar Wallabies
Biewener, A. A., Konieczynski, D. D., & Baudinette, R. V. (1998) · Journal of Experimental Biology · doi:10.1242/jeb.201.11.1681 · Cited by 247
Structural Specialization in Tendons under Compression
Vogel, K. G., & Koob, T. J. (1989) · International Review of Cytology · doi:10.1016/s0074-7696(08)60632-4 · Cited by 232
In Vitro fatigue of Human Tendons
Schechtman, H., & Bader, D. L. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00033-x · Cited by 218
A model of bipedal locomotion on compliant legs
Alexander, R. M. (1992) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1992.0138 · Cited by 216
Self-citationArtificial Muscles: Actuators for Biorobotic Systems
Klute, G. K., Czerniecki, J. M., & Hannaford, B. (2002) · The International Journal of Robotics Research · doi:10.1177/027836402320556331 · Cited by 208
“1986), rat (Minns and Muckle 1982), sheep (Bennett et al. 1986; Ker et al. 1987), and wallaby (Bennett et al.”
BackgroundMethodInfluentialMusculoskeletal design in relation to body size
Biewener, A. A. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90374-v · Cited by 202
Behavior of fascicles and tendinous structures of human gastrocnemius during vertical jumping
Kurokawa, S., Fukunaga, T., & Fukashiro, S. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.4.1349 · Cited by 201
“It was presented that, in external tendons of large mammals, the mechanical hysteresis lay between 6 and 11% (8).”
BackgroundResultStrength training alters the viscoelastic properties of tendons in elderly humans
Reeves, N. D., Narici, M. V., & Maganaris, C. N. (2003) · Muscle & Nerve · doi:10.1002/mus.10392 · Cited by 181
Kuo, C. K., Marturano, J. E., & Tuan, R. S. (2010) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/1758-2555-2-20 · Cited by 179
“Reported tensile mechanical properties of B. Mori silk fibroin range between 5-9 GPa for elastic modulus, 250-400 MPa for tensile strength, and 23-26% for failure strain [47].”
BackgroundInfluentialMechanical properties of the human patellar tendon, in vivo
Hansen, P., Bojsen-Moller, J., Aagaard, P., Kjaer, M., & Magnusson, S. P. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.07.008 · Cited by 175
“At the same time, the modulus of the human patellar tendon in vivo was greater ( 1 GPa) than that reported for isolated human patellar tendon but similar to various animal tendons at comparable magnitude of stress (Bennett et al., 1986).”
BackgroundTensile properties of in vivo human tendinous tissue
Maganaris, C. N. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00047-7 · Cited by 170
Fracture Mechanics of Collagen Fibrils: Influence of Natural Cross-Links
Svensson, R. B., Mulder, H., Kovanen, V., & Magnusson, S. P. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.04.033 · Cited by 170
Fatigue Rupture of Wallaby Tail Tendons
Wang, X. T., Ker, R. F., & Alexander, R. M. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.3.847 · Cited by 169
Self-citationTendon properties in relation to muscular activity and physical training
Magnusson, S. P., Hansen, P., & Kjær, M. (2003) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2003.00308.x · Cited by 166
Effects of long-term exercise on the biomechanical properties of the Achilles tendon of guinea fowl
Buchanan, C. I., & Marsh, R. L. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.1.164 · Cited by 165
“Like the LG of guinea fowl, these muscles have in common short muscle fibers and long tendons that are well suited to act as storage sites for elastic energy (4, 18).”
BackgroundTransmission of forces within mammalian skeletal muscles
Monti, R. J., Roy, R. R., Hodgson, J. A., & Reggie Edgerton, V (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00189-4 · Cited by 164
“The potential for the tendon to serve as a sink for strain energy has been demonstrated in a number of species (Bennett et al., 1986; Ker, 1981).”
BackgroundBiewener, A. A., & Baudinette, R. V. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.9.1829 · Cited by 162
Biaxial strain and variable stiffness in aponeuroses
Azizi, E., & Roberts, T. J. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2009.173690 · Cited by 158
“The capacity for energy storage and recovery in tendons is typically calculated from stiffness values for tendons measured in isolated preparations (Bennett et al. 1986; Shadwick, 1990).”
BackgroundMechanical Properties of Tendons: Changes With Sterilization and Preservation
Smith, C. W., Young, I. S., & Kearney, J. N. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2795946 · Cited by 158
Energetics and optimization of human walking and running: The 2000 Raymond Pearl memorial lecture
McNeill Alexander, R. (2002) · American Journal of Human Biology · doi:10.1002/ajhb.10067 · Cited by 157
Fascial or Muscle Stretching? A Narrative Review
Stecco, C., Pirri, C., Fede, C., Yucesoy, C. A., De Caro, R., & Stecco, A. (2020) · Applied Sciences · doi:10.3390/app11010307 · Cited by 57
Aiello, B. R., Hardy, A. R., Cherian, C., Olsen, A. M., Orsbon, C. P., Hale, M. E., & Westneat, M. W. (2018) · Journal of Morphology · doi:10.1002/jmor.20830 · Cited by 14
“of fin rays in this study is considerably less than that of a fish’s acellular bone (Horton and Summers, 2009), and is more similar to that of tendon (Bennett et al., 1986).”
Background
Metadata
- Authors
- Bennett, M. B., Ker, R. F., Imery, N. J., & Alexander, R. M.
- Venue
- Journal of Zoology
- Publisher
- Wiley
- Published
- 1986-08
- Volume
- 209
- Issue
- 4
- Pages
- 537-548
- ISSN
- 0952-8369 (ISSN-L)
- 1469-7998
- OpenAlex
- W1978947795
- Cited by
- 368
- References
- 16
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.