Bioelectric impedance vector distribution in peritoneal dialysis patients with different hydration status
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND In continuous ambulatory peritoneal dialysis (CAPD), total body water (TBW) is estimated by functions of body weight, and by equations of bioelectric impedance analysis (BIA). These procedures may be biased with abnormal tissue hydration. We validated vector BIA (BIVA) patterns of hydration in CAPD patients, based on direct measurements of resistance (R) and reactance (Xc) (RXc graph) without knowledge of the body weight. METHODS Cross-sectional study in 200 adult CAPD patients from two groups: 149 patients (77 males and 72 females) without edema (BMI 24.3 kg/m2), and 51 (29 males and 22 females) with pitting edema (BMI 24.6 kg/m2). Single frequency (50 kHz), whole-body impedance vector was measured with both empty and filled peritoneal cavity. Vector distribution was compared with that from 726 healthy subjects, 1116 hemodialysis patients, and 50 nephrotic patients, all with a same BMI. The performance of BIVA was compared with indications of four anthropometry and four conventional BIA equations for TBW. RESULTS TBW estimates from anthropometry (Watson, Hume and Weyers, Chertow, and Johansson formulas) were misleading, indicating the same hydration in edema. TBW estimates from BIA equations indicated a 10% excess TBW in edema. BIVA were very sensitive to fluid overload, as both R (by 10%) and Xc (by 40%) were reduced in patients with edema (regardless of peritoneal filling). The vector distribution of individual CAPD patients without edema was superposable to that of the healthy, gender-specific, reference population (50%, 75%, and 95% tolerance ellipses, RXc graph) and close to the hemodialysis, presession distribution. Vectors from patients with edema were displaced downward on the RXc graph, out of the 75% ellipse (88% sensitivity and 87% specificity), and close to vectors from nephrotic patients. CONCLUSION CAPD prescription would keep or bring vectors of patients back into the 75% reference ellipse (border for progression from latent to apparent overhydration across the lower pole) regardless of body weight. Whether CAPD patients with vector within the target ellipse have better outcome needs longitudinal evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of total body water by bioelectrical impedance analysis
Kushner, R., & Schoeller, D. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.3.417 · Cited by 772
A new method for monitoring body fluid variation by bioimpedance analysis: The RXc graph
Piccoli, A., Rossi, B., Pillon, L., & Bucciante, G. (1994) · Kidney International · doi:10.1038/ki.1994.305 · Cited by 711
Self-citationSun, S. S., Chumlea, W. C., Heymsfield, S. B., Lukaski, H. C., Schoeller, D., Friedl, K., Kuczmarski, R. J., Flegal, K. M., Johnson, C. L., & Hubbard, V. S. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.2.331 · Cited by 692
Whole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429 · cited 7×
“The height (H) is used as a measure of the human conductor length [12, 14].”
BackgroundMethodResultInfluentialIs the Impedance index (ht2/R) significant in predicting total body water?
Kushner, R., Schoeller, D., Fjeld, C., & Danford, L. (1992) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/56.5.835 · Cited by 374 · cited 2×
“TBW volume was estimated by regression equations recommended in the literature, on the basis of either anthropometry data, known as the body weight fraction [4], Watson, Watson, and Batt [5], Hume and Weyers [6], Chertow et al (hemodialysis-specific) [7], and Johansson et al (CAPD-specific) [8] formulas, or through co…”
MethodWhy bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361 · cited 1×
“BIA equations produce TBW estimates with high accuracy but with a large prediction error for the individual subject (±6 to 8 L), which can be more useful in epidemiology than at the bedside [22, 26, 28, 29, 42].”
Background
Cited by
De Rosa, S., Samoni, S., Villa, G., & Ronco, C. (2017) · Blood Purification · doi:10.1159/000452650 · Cited by 5,007
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Norman, K., Stobäus, N., Pirlich, M., & Bosy-Westphal, A. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.008 · Cited by 1,049
Bosy‐Westphal, A., Danielzik, S., Dörhöfer, R., Later, W., Wiese, S., & Müller, M. J. (2006) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607106030004309 · Cited by 595
Metadata
- Authors
- Piccoli, A., & for the Italian CAPD-BIA Study Group
- Venue
- Kidney International
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 65
- Issue
- 3
- Pages
- 1050-1063
- ISSN
- 0085-2538 (ISSN-L)
- OpenAlex
- W2084901186
- Cited by
- 132
- References
- 6
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioelectric impedance vector distribution in peritoneal dialysis patients with different hydration status. https://app.cochat.ai/papers/10.1111/j.1523-1755.2004.00467.x
- The paper
- Piccoli, A., & for the Italian CAPD-BIA Study Group. (2004). Bioelectric impedance vector distribution in peritoneal dialysis patients with different hydration status. Kidney International. https://doi.org/10.1111/j.1523-1755.2004.00467.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.