The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Optical coherence tomography in dermatology
Open accessAbstract
Optical coherence tomography (OCT) is a noninvasive diagnostic method that offers a view into the superficial layers of the skin in vivo in real-time. An infrared broadband light source allows the investigation of skin architecture and changes up to a depth of 1 to 2 mm with a resolution between 15 and 3 μm, depending on the system used. Thus OCT enables evaluation of skin lesions, especially nonmelanoma skin cancers and inflammatory diseases, quantification of skin changes, visualization of parasitic infestations, and examination of other indications such as the investigation of nails. OCT provides a quick and useful diagnostic imaging technique for a number of clinical questions and is a valuable addition or complement to other noninvasive imaging tools such as dermoscopy, high-frequency ultrasound, and confocal laser scan microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Lasers in Surgery and Medicine
(2006) · Lasers in Surgery and Medicine · doi:10.1002/(issn)1096-9101 · Cited by 1,088
Optical coherence tomography in dermatology: a review
Welzel, J. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.007001001.x · Cited by 621
Self-citationTearney, G. J., Brezinski, M. E., Bouma, B. E., Hee, M. R., Southern, J. F., & Fujimoto, J. G. (1995) · Optics Letters · doi:10.1364/ol.20.002258 · Cited by 562
Ultrahigh-resolution optical coherence tomography
Drexler, W. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629679 · Cited by 553
Optical coherence tomography of the human skin
Welzel, J., Lankenau, E., Birngruber, R., & Engelhardt, R. (1997) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(97)70072-0 · Cited by 442
Self-citationUse of an agent to reduce scattering in skin
Vargas, G., Chan, E. K., Barton, J. K., Rylander, H. G., & Welch, A. J. (1999) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1999)24:2<133::aid-lsm9>3.0.co;2-x · Cited by 302
Applications of optical coherence tomography in dermatology
GAMBICHLER, T., MOUSSA, G., SAND, M., SAND, D., ALTMEYER, P., & HOFFMANN, K. (2005) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2005.07.006 · Cited by 283
Cited by
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
Metadata
- Authors
- Sattler, E., Kästle, R., & Welzel, J.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2013-01-11
- Volume
- 18
- Issue
- 6
- Pages
- 061224
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2024169430
- Cited by
- 283
- References
- 40
- FWCI
- 13.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical coherence tomography in dermatology. https://app.cochat.ai/papers/10.1117/1.jbo.18.6.061224
- The paper
- Sattler, E., Kästle, R., & Welzel, J. (2013). Optical coherence tomography in dermatology. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.18.6.061224
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.