Assessment of Optical Coherence Tomography Imaging in the Diagnosis of Non-Melanoma Skin Cancer and Benign Lesions Versus Normal Skin: Observer-Blinded Evaluation by Dermatologists and Pathologists
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Optical coherence tomography (OCT) is an optical imaging technique that may be useful in diagnosis of non-melanoma skin cancer (NMSC). OBJECTIVES: To describe OCT features in NMSC such as actinic keratosis (AK) and basal cell carcinoma (BCC) and in benign lesions and to assess the diagnostic accuracy of OCT in differentiating NMSC from benign lesions and normal skin. METHODS AND MATERIALS: OCT and polarization-sensitive (PS) OCT from 104 patients were studied. Observer-blinded evaluation of OCT images from 64 BCCs, 1 baso-squamous carcinoma, 39 AKs, two malignant melanomas, nine benign lesions, and 105 OCT images from perilesional skin was performed; 50 OCT images of NMSC and 50 PS-OCT images of normal skin were evaluated twice. RESULTS: Sensitivity was 79% to 94% and specificity 85% to 96% in differentiating normal skin from lesions. Important features were absence of well-defined layering in OCT and PS-OCT images and dark lobules in BCC. Discrimination of AK from BCC had an error rate of 50% to 52%. CONCLUSION: OCT features in NMSC are identified, but AK and BCC cannot be differentiated. OCT diagnosis is less accurate than clinical diagnosis, but high accuracy in distinguishing lesions from normal skin, crucial for delineating tumor borders, was obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033 · cited 2×
“Optical coherence tomography (OCT) is an optical imaging technology that offers real-time imaging with micrometer resolution.(4,5) Skin is imaged by measuring the backscatter and reflection of infrared light directed toward the skin.”
BackgroundMethodLikelihood ratios with confidence: Sample size estimation for diagnostic test studies
Simel, D. L., Samsa, G. P., & Matchar, D. B. (1991) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(91)90128-v · Cited by 932
Optical coherence tomography in dermatology: a review
Welzel, J. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.007001001.x · Cited by 621 · cited 1×
“OCT is a noninvasive optical imaging technology that can provide cross-sectional tomographic images of tissue in situ and in real-time with high axial resolution.(4,8,18) The OCT system used was developed at the Technical University of Denmark.”
MethodPolarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582 · cited 1×
“In polarization-sensitive OCT (PS-OCT) the birefringence of tissue can be measured.(19) In our OCT system, PS-OCT images are recorded in parallel with standard OCT images.”
BackgroundOptical coherence tomography of the human skin
Welzel, J., Lankenau, E., Birngruber, R., & Engelhardt, R. (1997) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(97)70072-0 · Cited by 442
Nori, S., Rius-Díaz, F., Cuevas, J., Goldgeier, M., Jaen, P., Torres, A., & González, S. (2004) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2004.06.028 · Cited by 364
Management of nonmelanoma skin cancer in 2007
Neville, J. A., Welch, E., & Leffell, D. J. (2007) · Nature Clinical Practice Oncology · doi:10.1038/ncponc0883 · Cited by 278
Advances in Optical Coherence Tomography Imaging for Dermatology
Pierce, M. C., Strasswimmer, J., Hyle Park, B., Cense, B., & de Boer, J. F. (2004) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2004.23404.x · Cited by 257 · cited 8×
“We demonstrated a characteristic OCT morphology of AK, BCC, and normal adjacent skin in accordance with other studies,6,10,11,14,20,26–28 and we discovered the OCT morphology matches well-known histopathology of NMSC.”
BackgroundInfluentialGambichler, T., Matip, R., Moussa, G., Altmeyer, P., & Hoffmann, K. (2006) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2006.09.008 · Cited by 239 · cited 1×
“When OCT images from the same lesions were compared, they looked similar, in concordance with the high reproducibility of OCT images demonstrated in earlier studies of epidermis and nail thickness measurements.(20,29,30)”
Result
Cited by
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Polarization sensitive optical coherence tomography – a review [Invited]
de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001838 · Cited by 454
Optical coherence tomography in dermatology
Sattler, E., Kästle, R., & Welzel, J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061224 · Cited by 283
Optical coherence tomography in dermatology: technical and clinical aspects
Gambichler, T., Jaedicke, V., & Terras, S. (2011) · Archives of Dermatological Research · doi:10.1007/s00403-011-1152-x · Cited by 240
“that AK and BCC cannot be discriminated based on the OCT images alone [50, 67].”
BackgroundMethodDynamic Optical Coherence Tomography in Dermatology
Ulrich, M., Themstrup, L., de Carvalho, N., Manfredi, M., Grana, C., Ciardo, S., Kästle, R., Holmes, J., Whitehead, R., Jemec, G. B. E., et al. (2016) · Dermatology · doi:10.1159/000444706 · Cited by 230
Self-citationUpdate of the European guidelines for basal cell carcinoma management
Trakatelli, M., Morton, C., Nagore, E., Ulrich, C., Del Marmol, V., Peris, K., & Basset-Seguin, N. (2014) · European Journal of Dermatology · doi:10.1684/ejd.2014.2271 · Cited by 228
OCT imaging of skin cancer and other dermatological diseases
Mogensen, M., Thrane, L., Jørgensen, T. M., Andersen, P. E., & Jemec, G. B. E. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910020 · Cited by 201
Self-citationOptical Coherence Tomography Enhanced Depth Imaging of Choroidal Tumors
Torres, V. L. L., Brugnoni, N., Kaiser, P. K., & Singh, A. D. (2011) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.09.028 · Cited by 187
Review of optical coherence tomography in oncology
Wang, J., Xu, Y., & Boppart, S. A. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121711 · Cited by 172
Advances in optical coherence tomography in dermatology—a review
Olsen, J., Holmes, J., & Jemec, G. B. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.4.040901 · Cited by 165
Self-citationUlrich, M., Braunmuehl, T., Kurzen, H., Dirschka, T., Kellner, C., Sattler, E., Berking, C., Welzel, J., & Reinhold, U. (2015) · British Journal of Dermatology · doi:10.1111/bjd.13853 · Cited by 160
Cheng, H. M., & Guitera, P. (2015) · British Journal of Dermatology · doi:10.1111/bjd.14042 · Cited by 65
Actinic Keratosis and Non-Invasive Diagnostic Techniques: An Update
Casari, A., Chester, J., & Pellacani, G. (2018) · Biomedicines · doi:10.3390/biomedicines6010008 · Cited by 64
“[49] the sensitivity of recognizing AK and BCC in regular OCT was only 46%.”
BackgroundMaier, T., Braun-Falco, M., Laubender, R. P., Ruzicka, T., & Berking, C. (2013) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2012.11202.x · Cited by 57
Metadata
- Authors
- MOGENSEN, M., JOERGENSEN, T. M., NÜRNBERG, B. M., MORSY, H. A., THOMSEN, J. B., THRANE, L., & JEMEC, G. B. E.
- Venue
- Dermatologic Surgery
- Published
- 2009-06
- Volume
- 35
- Issue
- 6
- Pages
- 965-972
- ISSN
- 1076-0512 (ISSN-L)
- OpenAlex
- W2015186058
- Cited by
- 205
- References
- 27
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.