A new microparticle size calibration standard for use in measuring smaller microparticles using a new flow cytometer
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vesicles of variable sizes produced by a rapid extrusion procedure
Mayer, L. D., Hope, M. J., & Cullis, P. R. (1986) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(86)90302-0 · Cited by 1,691
Small-volume extrusion apparatus for preparation of large, unilamellar vesicles
MacDonald, R. C., MacDonald, R. I., Menco, B. P. M., Takeshita, K., Subbarao, N. K., & Hu, L.-R. (1991) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(91)90295-j · Cited by 1,493
Heijnen, H. F. G., Schiel, A. E., Fijnheer, R., Geuze, H. J., & Sixma, J. J. (1999) · Blood · doi:10.1182/blood.v94.11.3791 · Cited by 1,487
Circulating microparticles: pathophysiology and clinical implications
Piccin, A., Murphy, W. G., & Smith, O. P. (2007) · Blood Reviews · doi:10.1016/j.blre.2006.09.001 · Cited by 799
Shet, A. S., Aras, O., Gupta, K., Hass, M. J., Rausch, D. J., Saba, N., Koopmeiners, L., Key, N. S., & Hebbel, R. P. (2003) · Blood · doi:10.1182/blood-2003-03-0693 · Cited by 539
Optical and non‐optical methods for detection and characterization of microparticles and exosomes
VAN DER POL, E., HOEKSTRA, A. G., STURK, A., OTTO, C., VAN LEEUWEN, T. G., & NIEUWLAND, R. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04074.x · Cited by 535
Zwicker, J. I., Liebman, H. A., Neuberg, D., Lacroix, R., Bauer, K. A., Furie, B. C., & Furie, B. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-09-0371 · Cited by 479
LACROIX, R., ROBERT, S., PONCELET, P., KASTHURI, R. S., KEY, N. S., & DIGNAT‐GEORGE, F. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04047.x · Cited by 351
Flow cytometric analysis of circulating microparticles in plasma
Orozco, A. F., & Lewis, D. E. (2010) · Cytometry Part A · doi:10.1002/cyto.a.20886 · Cited by 333
Biró, É., Sturk-Maquelin, K. N., Vogel, G. M. T., Meuleman, D. G., Smit, M. J., Hack, C. E., Sturk, A., & Nieuwland, R. (2003) · Journal of Thrombosis and Haemostasis · doi:10.1046/j.1538-7836.2003.00456.x · Cited by 314
Cited by
Witwer, K. W., Buzás, E. I., Bemis, L. T., Bora, A., Lässer, C., Lötvall, J., Nolte‐‘t Hoen, E. N., Piper, M. G., Sivaraman, S., Skog, J., et al. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.20360 · Cited by 2,421
Classification, Functions, and Clinical Relevance of Extracellular Vesicles
van der Pol, E., Böing, A. N., Harrison, P., Sturk, A., & Nieuwland, R. (2012) · Pharmacological Reviews · doi:10.1124/pr.112.005983 · Cited by 1,754
Gurunathan, S., Kang, M.-H., Jeyaraj, M., Qasim, M., & Kim, J.-H. (2019) · Cells · doi:10.3390/cells8040307 · Cited by 1,122
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Arraud, N., Linares, R., Tan, S., Gounou, C., Pasquet, J. ‐., Mornet, S., & Brisson, A. R. (2014) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12554 · Cited by 740
Isolation, cultivation, and characterization of human mesenchymal stem cells
Mushahary, D., Spittler, A., Kasper, C., Weber, V., & Charwat, V. (2018) · Cytometry Part A · doi:10.1002/cyto.a.23242 · Cited by 599
Extracellular vesicle sizing and enumeration by nanoparticle tracking analysis
Gardiner, C., Ferreira, Y. J., Dragovic, R. A., Redman, C. W. G., & Sargent, I. L. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.19671 · Cited by 584
High‐speed centrifugation induces aggregation of extracellular vesicles
Linares, R., Tan, S., Gounou, C., Arraud, N., & Brisson, A. R. (2015) · Journal of Extracellular Vesicles · doi:10.3402/jev.v4.29509 · Cited by 571
The Methods of Choice for Extracellular Vesicles (EVs) Characterization
Szatanek, R., Baj-Krzyworzeka, M., Zimoch, J., Lekka, M., Siedlar, M., & Baran, J. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18061153 · Cited by 563
van der Vlist, E. J., Nolte-'t Hoen, E. N. M., Stoorvogel, W., Arkesteijn, G. J. A., & Wauben, M. H. M. (2012) · Nature Protocols · doi:10.1038/nprot.2012.065 · Cited by 532
Technical challenges of working with extracellular vesicles
Ramirez, M. I., Amorim, M. G., Gadelha, C., Milic, I., Welsh, J. A., Freitas, V. M., Nawaz, M., Akbar, N., Couch, Y., Makin, L., et al. (2018) · Nanoscale · doi:10.1039/c7nr08360b · Cited by 516
Welsh, J. A., Van Der Pol, E., Arkesteijn, G. J. A., Bremer, M., Brisson, A., Coumans, F., Dignat‐George, F., Duggan, E., Ghiran, I., Giebel, B., et al. (2020) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2020.1713526 · Cited by 481
Single vs. swarm detection of microparticles and exosomes by flow cytometry
Van Der POL, E., Van GEMERT, M. J. C., STURK, A., NIEUWLAND, R., & Van LEEUWEN, T. G. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2012.04683.x · Cited by 421
Pospichalova, V., Svoboda, J., Dave, Z., Kotrbova, A., Kaiser, K., Klemova, D., Ilkovics, L., Hampl, A., Crha, I., Jandakova, E., et al. (2015) · Journal of Extracellular Vesicles · doi:10.3402/jev.v4.25530 · Cited by 387
Extracellular Vesicle Quantification and Characterization: Common Methods and Emerging Approaches
Hartjes, T. A., Mytnyk, S., Jenster, G. W., van Steijn, V., & van Royen, M. E. (2019) · Bioengineering · doi:10.3390/bioengineering6010007 · Cited by 342
Görgens, A., Bremer, M., Ferrer‐Tur, R., Murke, F., Tertel, T., Horn, P. A., Thalmann, S., Welsh, J. A., Probst, C., Guerin, C., et al. (2019) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2019.1587567 · Cited by 337
Isolation of extracellular vesicles: Determining the correct approach (Review)
SZATANEK, R., BARAN, J., SIEDLAR, M., & BAJ-KRZYWORZEKA, M. (2015) · International Journal of Molecular Medicine · doi:10.3892/ijmm.2015.2194 · Cited by 280
Lőrincz, Á. M., Timár, C. I., Marosvári, K. A., Veres, D. S., Otrokocsi, L., Kittel, Á., & Ligeti, E. (2014) · Journal of Extracellular Vesicles · doi:10.3402/jev.v3.25465 · Cited by 264
Danesh, A., Inglis, H. C., Jackman, R. P., Wu, S., Deng, X., Muench, M. O., Heitman, J. W., & Norris, P. J. (2014) · Blood · doi:10.1182/blood-2013-10-530469 · Cited by 250
Innovation in detection of microparticles and exosomes
van der Pol, E., Coumans, F., Varga, Z., Krumrey, M., & Nieuwland, R. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12254 · Cited by 250
Zhu, S., Ma, L., Wang, S., Chen, C., Zhang, W., Yang, L., Hang, W., Nolan, J. P., Wu, L., & Yan, X. (2014) · ACS Nano · doi:10.1021/nn505162u · Cited by 232
“org 11001 a polystyrene nanoparticle of the same size.(31) Therefore, pushing the detection limit for single dielectric nanoparticles from the previous state-of-the-art detection of ∼75 nm diameter polystyrene nanoparticles(22) down to ∼25 nm silica nanoparticles in the present study represents a gain of more than 3 o…”
BackgroundAnalytical challenges of extracellular vesicle detection: A comparison of different techniques
Erdbrügger, U., & Lannigan, J. (2016) · Cytometry Part A · doi:10.1002/cyto.a.22795 · Cited by 230
“Using these approaches, they are most likely measuring larger particles than stated or even more likely, whole cells (12,19).”
BackgroundMethodInfluentialMethodology for isolation, identification and characterization of microvesicles in peripheral blood
Jayachandran, M., Miller, V. M., Heit, J. A., & Owen, W. G. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2011.10.012 · Cited by 227
High sensitivity flow cytometry of membrane vesicles
Stoner, S. A., Duggan, E., Condello, D., Guerrero, A., Turk, J. R., Narayanan, P. K., & Nolan, J. P. (2016) · Cytometry Part A · doi:10.1002/cyto.a.22787 · Cited by 223
“ibration approaches are invalid, owing to the differences in refractive index of EVs compared with polymer beads (11,12).”
Tatischeff, I., Larquet, E., Falcón‐Pérez, J. M., Turpin, P., & Kruglik, S. G. (2012) · Journal of Extracellular Vesicles · doi:10.3402/jev.v1i0.19179 · Cited by 219
“However, recent improvements allow flow cytometry analysis of nano-sized EVs (5,6) and this fast technique”
BackgroundCutting-Edge Analysis of Extracellular Microparticles using ImageStreamX Imaging Flow Cytometry
Headland, S. E., Jones, H. R., D'Sa, A. S. V., Perretti, M., & Norling, L. V. (2014) · Scientific Reports · doi:10.1038/srep05237 · Cited by 211
Extracellular Vesicles in Renal Diseases: More than Novel Biomarkers?
Erdbrügger, U., & Le, T. H. (2016) · Journal of the American Society of Nephrology · doi:10.1681/asn.2015010074 · Cited by 204
Refractive Index Determination of Nanoparticles in Suspension Using Nanoparticle Tracking Analysis
van der Pol, E., Coumans, F. A. W., Sturk, A., Nieuwland, R., & van Leeuwen, T. G. (2014) · Nano Letters · doi:10.1021/nl503371p · Cited by 203
Novel methodologies for biomarker discovery in atherosclerosis
Hoefer, I. E., Steffens, S., Ala-Korpela, M., Bäck, M., Badimon, L., Bochaton-Piallat, M.-L., Boulanger, C. M., Caligiuri, G., Dimmeler, S., Egido, J., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv236 · Cited by 200
Kormelink, T. G., Arkesteijn, G. J. A., Nauwelaers, F. A., van den Engh, G., Nolte‐'t Hoen, E. N. M., & Wauben, M. H. M. (2016) · Cytometry Part A · doi:10.1002/cyto.a.22644 · Cited by 191
“Scatter signal is highly dependent on the size and RI (15–19).”
Gardiner, C., Shaw, M., Hole, P., Smith, J., Tannetta, D., Redman, C. W., & Sargent, I. L. (2014) · Journal of Extracellular Vesicles · doi:10.3402/jev.v3.25361 · Cited by 186
“Furthermore, the lower limit of size resolution by FCM also depends on RI (3).”
García‐Manrique, P., Matos, M., Gutiérrez, G., Pazos, C., & Blanco‐López, M. C. (2018) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2017.1422676 · Cited by 182
“efficacy and physical integrity [47], detection by flow cytometry [104] and EV refractive index study [105].”
van der Pol, E., Sturk, A., van Leeuwen, T., Nieuwland, R., Coumans, F., Mobarrez, F., Arkesteijn, G., Wauben, M., Siljander, P. R. ‐., Sánchez‐López, V., et al. (2018) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14009 · Cited by 182
Self-citationPreparation and characterization of extracellular vesicles
Tiwari, S., Kumar, V., Randhawa, S., & Verma, S. K. (2021) · American Journal of Reproductive Immunology · doi:10.1111/aji.13367 · Cited by 182
Tannetta, D. S., Dragovic, R. A., Gardiner, C., Redman, C. W., & Sargent, I. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056754 · Cited by 181
Brisson, A. R., Tan, S., Linares, R., Gounou, C., & Arraud, N. (2017) · Platelets · doi:10.1080/09537104.2016.1268255 · Cited by 179
“with reported values for total EV concentrations varying from 200 to 10(9) per μL plasma [13].”
BackgroundErdbrügger, U., Rudy, C. K., E. Etter, M., Dryden, K. A., Yeager, M., Klibanov, A. L., & Lannigan, J. (2014) · Cytometry Part A · doi:10.1002/cyto.a.22494 · Cited by 179
“Use of Lipid-Based MVs for Evaluating Instrument Sensitivity It is well-known that PS beads have a significantly higher refractive index (RI) and scatter approximately 10 times more light than biological particles (7).”
BackgroundResultInfluentialArraud, N., Gounou, C., Turpin, D., & Brisson, A. R. (2016) · Cytometry Part A · doi:10.1002/cyto.a.22669 · Cited by 179
“In continuation with progresses made in the standardization of sample preparation conditions (40) and particle size calibration protocols for light scatter triggering measurements (18,24,56,57), standardized procedures need to be established for the FL triggering approach to allow reliable comparison of”
BackgroundMethodInfluentialALEMAN, M. M., GARDINER, C., HARRISON, P., & WOLBERG, A. S. (2011) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04488.x · Cited by 178
“5 μm) than initially reported (≤1 μm)[25], use of flow cytometry to characterize and enumerate MPs is controversial; the refractive index of cellular vesicles appears lower than that of polystyrene beads used to gate MP populations by flow cytometry, leading to underestimation of size.[29] Our data are consistent with…”
Toward characterizing extracellular vesicles at a single-particle level
Chiang, C.-Y., & Chen, C. (2019) · Journal of Biomedical Science · doi:10.1186/s12929-019-0502-4 · Cited by 166
Koritzinsky, E. H., Street, J. M., Star, R. A., & Yuen, P. S. T. (2017) · Journal of Cellular Physiology · doi:10.1002/jcp.25387 · Cited by 164
Robert, S., Lacroix, R., Poncelet, P., Harhouri, K., Bouriche, T., Judicone, C., Wischhusen, J., Arnaud, L., & Dignat-George, F. (2012) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.111.244616 · Cited by 163
Pick, H., Alves, A. C., & Vogel, H. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00777 · Cited by 160
Storage Stability of Blood Samples for miRNAs in Glycosylated Extracellular Vesicles
Ma, C., Ding, R., Hao, K., Du, W., Xu, L., Gao, Q., & Yu, C. (2023) · Molecules · doi:10.3390/molecules29010103 · Cited by 22
“The resulting serum was carefully collected and stored at − 80 ◦ C, ensuring optimal preservation for subsequent experimental investigations.”
Background
Metadata
- Authors
- CHANDLER, W. L., YEUNG, W., & TAIT, J. F.
- Venue
- Journal of Thrombosis and Haemostasis
- Publisher
- Elsevier BV
- Published
- 2011-06
- Volume
- 9
- Issue
- 6
- Pages
- 1216-1224
- ISSN
- 1538-7836 (ISSN-L)
- OpenAlex
- W1562385120
- Cited by
- 273
- References
- 20
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.