Phrenic Nerve Stimulation for Central Ventilatory Failure with Bipolar and Four‐Pole Electrode Systems
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A multi‐channel phrenic nerve stimulator developed in Tampere has been implanted into seven patients with C 2‐etraplegia and into three patients with central sleep apneas. Six bipolar cuff electrodes were implanted bilaterally into the neck. Two four‐pole cuff and 14 four‐pole noncuff electrodes were used in seven patients and to replace one bipolar electrode. Four‐pole electrodes were implanted within the thorax. Seven patients achieved total independence from conventional ventilators within 4 months of implantation, and one for 18 hours each day. Two patients died 12 days and 3 months after implantation and two patients after having achieved independence from mechanical ventilators from causes unrelated to the simulators. Reoperations were necessary because of dislocation of receivers, electrodes, electrode lesions, nerve injuries, and technical failures in seven patients. Most of the problems appeared in two patients with obesity and in three patients with very thin phrenic nerves. Single unit prototypes failed technically more frequently than units of prototype serial fabrication. New electrode design, progress in the manufacture of receivers, and improved implantation technique should help to diminish failures in future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
Twenty Years of Experience in Phrenic Nerve Stimulation to Pace the Diaphragm
GLENN, W. W. L., PHELPS, M. L., ELEFTERLEADES, J. A., DENTZ, B., & HOGAN, J. F. (1986) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1986.tb06627.x · Cited by 125
Diaphragm pacing by electrical stimulation of the phrenic nerve
Glenn, W. W., & Phelps, M. L. (1985) · Neurosurgery · doi:10.1097/00006123-198512000-00021 · Cited by 15
Cited by
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
(1996) · PubMed · Cited by 79
Christensen, M. B., Wark, H. A. C., & Hutchinson, D. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.11.012 · Cited by 49
Romero, E., Denef, J. F., Delbeke, J., Robert, A., & Veraart, C. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345271 · Cited by 49
KOLLER, R., GIRSCH, W., LIEGL, C., CRUDER, H., HOLLE, J., LOSERT, U., MAYR, W., & THOMA, H. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02906.x · Cited by 17
Metadata
- Authors
- BAER, G. A., TALONEN, P. P., SHNEERSON, J. M., MARKKULA, H., EXNER, G., & WELLS, F. C.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1990-08
- Volume
- 13
- Issue
- 8
- Pages
- 1061-1072
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2022020973
- Cited by
- 42
- References
- 3
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phrenic Nerve Stimulation for Central Ventilatory Failure with Bipolar and Four‐Pole Electrode Systems. https://app.cochat.ai/papers/10.1111/j.1540-8159.1990.tb02153.x
- The paper
- BAER, G. A., TALONEN, P. P., SHNEERSON, J. M., MARKKULA, H., EXNER, G., & WELLS, F. C. (1990). Phrenic Nerve Stimulation for Central Ventilatory Failure with Bipolar and Four‐Pole Electrode Systems. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1990.tb02153.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.