CoChat

Correlates of Patient Acceptance of the Cardioverter Defibrillator: Cross‐Validation of the Florida Patient Acceptance Survey in Danish Patients

PEDERSEN, SUSANNE S., SPINDLER, HELLE, JOHANSEN, JENS B., MORTENSEN, PETER T., SEARS, SAMUEL F. · 2008 · Pacing and Clinical Electrophysiology
Cited by 58

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Device acceptance may comprise one of the keys to identifying implantable cardioverter defibrillator (ICD) patients at risk for adverse health outcomes in clinical practice. We examined (1) the validity and reliability of the Florida Patient Acceptance Survey (FPAS) and (2) correlates of device acceptance in a large sample of Danish patients. Methods: A cohort of consecutive patients (N = 566; 82.2% males; mean age = 61.9 ± 14.3) implanted with an ICD since 1989 and still alive on November 1, 2006, completed a set of psychological questionnaires. Results: The four‐factor structure and the validity of the FPAS were confirmed, with the four factors accounting for 64.3% of the variance. The reliability, measured by Cronbach's α, was acceptable for the total scale and all subscales, ranging from 0.73 to 0.85. Correlates of poor device acceptance included older age (OR: 1.03; 95% CI: 1.01–1.05), symptomatic heart failure (OR: 3.59; 95% CI: 2.12–6.08), Type D personality (OR: 3.51; 95% CI: 1.95–6.30), anxiety (OR: 2.33; 95% CI: 1.24–4.38), depressive symptoms (OR: 2.24; 95% CI: 1.00–5.00), and ICD concerns (OR: 4.16; 95% CI: 2.55–6.80); having a partner was associated with better acceptance (OR: 0.53; 95% CI: 0.31–0.91), adjusting for demographic and clinical factors including shocks. Shocks were not associated with outcome (P = 0.59). Conclusions: The FPAS was shown to be a valid and reliable measure of device acceptance in a large sample of Danish ICD patients. Psychological factors rather than clinical factors were the primary correlates of poor device acceptance, whereas having a partner was associated with better acceptance. These preliminary findings suggest that screening for psychological factors may aid clinicians in identifying patients at risk of poor device acceptance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2008.01158.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 34

  1. 10.1023/A:1023603118860 · DOI
  2. 10.1016/S0002-9149(98)01007-8 · DOI
  3. 10.1001/jama.289.20.2685 · DOI
  4. Cleland JG, 2006, on behalf of The CARE‐HF study investigators, Eur Heart J, 27, 1928
  5. 10.1136/heart.87.5.488 · DOI · Paper page
  6. 10.1111/j.1540-8159.2006.00409.x · DOI · Paper page
  7. 10.1002/(SICI)1520-6394(1999)9:4<163::AID-DA3>3.0.CO;2-B · DOI · Paper page
  8. 10.1016/j.jacc.2004.12.053 · DOI · Paper page
  9. 10.1111/j.1540-8167.2004.03406.x · DOI
  10. 10.1111/j.1540-8159.2007.00694.x · DOI · Paper page
  11. 10.1046/j.1540-8167.2005.40134.x · DOI · Paper page
  12. 10.1093/europace/eun073 · DOI · Paper page
  13. 10.1111/j.1540-8159.2000.tb01340.x · doi:10.1111/j.1540-8159.2000.tb01340.x
  14. Rector TS, 1987, Patients' self‐assessment of their congestive heart failure: Content, reliability and validity of a new measure—the Minnesota Living With Heart Failure Questionnaire, Heart Fail, 3, 198
  15. 10.1023/A:1008846618880 · DOI
  16. 10.1348/135910705X52264 · DOI · Paper page
  17. 10.1016/j.ahj.2004.06.031 · DOI · Paper page
  18. 10.1097/01.psy.0000149256.81953.49 · DOI · Paper page
  19. Denollet J, 2006, Social inhibition modulates the effect of negative emotions on cardiac prognosis following percutaneous coronary intervention in the drug‐eluting stent era, Eur Heart J, 171, 10.1093/eurheartj/ehi616 · DOI · Paper page
  20. 10.1016/j.jpsychores.2007.03.010 · DOI · Paper page
  21. 10.1016/j.jpsychores.2007.06.005 · DOI
  22. 10.1111/j.1600-0447.1983.tb09716.x · DOI · Paper page
  23. 10.1016/S0022-3999(01)00296-3 · DOI · Paper page
  24. 10.1067/mhj.2003.177 · DOI
  25. 10.1111/j.1467-6494.1986.tb00391.x · DOI · Paper page
  26. 10.1037/1040-3590.7.3.309 · DOI · Paper page
  27. 10.1093/europace/eum041 · DOI · Paper page
  28. 10.1111/j.1540-8159.2007.00921.x · DOI
  29. Pedersen SS, Poor perceived social support in ICD patients and their partners: Cross‐validation of the Multidimensional Scale of Perceived Social Support, Psychosomatics
  30. 10.1016/j.ahj.2007.01.020 · DOI
  31. 10.1161/01.CIR.0000145610.64014.E4 · DOI · Paper page
  32. 10.1111/j.1540-8159.2007.00905.x · DOI · Paper page
  33. 10.1037/0022-006X.72.6.1175 · DOI · Paper page
  34. 10.1111/j.1540-8159.2007.00773.x · DOI · Paper page

Cited by

See all 58

Metadata

Authors
PEDERSEN, S. S., SPINDLER, H., JOHANSEN, J. B., MORTENSEN, P. T., & SEARS, S. F.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2008-08-28
Volume
31
Issue
9
Pages
1168-1177
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2126347959
Cited by
58
References
4
FWCI
4.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlates of Patient Acceptance of the Cardioverter Defibrillator: Cross‐Validation of the Florida Patient Acceptance Survey in Danish Patients. https://app.cochat.ai/papers/10.1111/j.1540-8159.2008.01158.x
The paper
PEDERSEN, S. S., SPINDLER, H., JOHANSEN, J. B., MORTENSEN, P. T., & SEARS, S. F. (2008). Correlates of Patient Acceptance of the Cardioverter Defibrillator: Cross‐Validation of the Florida Patient Acceptance Survey in Danish Patients. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2008.01158.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.