Prevalence and Persistence of Depression in Patients with Implantable Cardioverter Defibrillator: A 2‐year Longitudinal Study
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: It is unclear whether depression persists in patients with implantable cardioverter defibrillators (ICDs). We evaluated the prevalence and persistence of depression in ICD patients over a 2‐year period. Methods: The study included 90 consecutively hospitalized patients. Patients underlying heart disease was 24% coronary artery disease, 29% idiopathic dilated cardiomyopathy, 24% hypertrophic cardiomyopathy, 13% idiopathic VF/long QT syndrome and miscellaneous conditions 11%. A secondary indication for ICD implantation was present in 20 patients. All patients completed the Zung Self‐Rating Depression Scale (SDS) at study baseline and at the their routine follow‐up visit 2 years after the baseline questionnaire. Delivery of ICD therapies was tracked throughout the 2 years. Results: Depression, indicated by a Zung SDS index score exceeding 60, was present in 29 (32%) of patients at study baseline. Depression was present in 11/51 (21%) patients scheduled to undergo ICD implantation, 2/2 (100%) patients whose device was upgraded to a CRT‐D, 3/14 (21%) patients who had undergone pulse generator replacement, 7/14 (50%) patients who experienced electrical storm and 6/9 (66%) patients hospitalized with acute decompensated heart failure. NYHA functional class III was significantly associated with depression at baseline (HR 6.7, 95% CI 1.68–27.2, p = 0.0007). No differences were noted for female gender, demographics, β‐blocker use, or LVEF ≤35% (p = ns). Depression was present in 25 (28%) of patients at 2 years follow‐up, persisting in 21 (72%) of patients whose Zung SDS scores were elevated at baseline. The median time from ICD shock therapy to completion of the 2 year questionnaire was 9 months (range, 1–22). Patients who were depressed (9/25, 36%) experienced more shocks than non‐depressed patients (6/65, 9%) after 2 years (p = 0.002). Conclusions: Depression is not uncommon among patients who meet criteria for ICD implantation and persists over time particularly when functional status is impaired. Depression is associated with a higher incidence shock therapy. (PACE 2010; 33:1455–1461)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rozanski, A., Blumenthal, J. A., & Kaplan, J. (1999) · Circulation · doi:10.1161/01.cir.99.16.2192 · Cited by 2,846
Rutledge, T., Reis, V. A., Linke, S. E., Greenberg, B. H., & Mills, P. J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.06.055 · Cited by 1,513
Jiang, W., Alexander, J., Christopher, E., Kuchibhatla, M., Gaulden, L. H., Cuffe, M. S., Blazing, M. A., Davenport, C., Califf, R. M., Krishnan, R. R., et al. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.15.1849 · Cited by 934
Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Quality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368
Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
Depression and Cardiovascular Disease: Healing the Broken-Hearted
Whooley, M. A. (2006) · JAMA · doi:10.1001/jama.295.24.2874 · Cited by 251
Psychopathology in Patients with ICDs over Time: Results of a Prospective Study
KAPA, S., ROTONDI-TREVISAN, D., MARIANO, Z., AVES, T., IRVINE, J., DORIAN, P., & HAYES, D. L. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02599.x · Cited by 112
Cited by
Depression and cardiovascular disease: a clinical review
Hare, D. L., Toukhsati, S. R., Johansson, P., & Jaarsma, T. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht462 · Cited by 1,362
Depression and cardiac disease: epidemiology, mechanisms, and diagnosis.
Huffman, J. C., Celano, C. M., Beach, S. R., Motiwala, S. R., & Januzzi, J. L. (2013) · Cardiovascular Psychiatry and Neurology · doi:10.1155/2013/695925 · Cited by 445
Depression and Cardiac Disease: A Review
Celano, C. M., & Huffman, J. C. (2011) · Cardiology in Review · doi:10.1097/crd.0b013e31820e8106 · Cited by 320
Dunbar, S. B., Dougherty, C. M., Sears, S. F., Carroll, D. L., Goldstein, N. E., Mark, D. B., McDaniel, G., Pressler, S. J., Schron, E., Wang, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31825d59fd · Cited by 221
Metadata
- Authors
- SUZUKI, T., SHIGA, T., KUWAHARA, K., KOBAYASHI, S., SUZUKI, S., NISHIMURA, K., SUZUKI, A., EJIMA, K., MANAKA, T., SHODA, M., ISHIGOOKA, J., KASANUKI, H., & HAGIWARA, N.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2010-10-14
- Volume
- 33
- Issue
- 12
- Pages
- 1455-1461
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1562961168
- Cited by
- 68
- References
- 8
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prevalence and Persistence of Depression in Patients with Implantable Cardioverter Defibrillator: A 2‐year Longitudinal Study. https://app.cochat.ai/papers/10.1111/j.1540-8159.2010.02887.x
- The paper
- SUZUKI, T., SHIGA, T., KUWAHARA, K., KOBAYASHI, S., SUZUKI, S., NISHIMURA, K., SUZUKI, A., EJIMA, K., MANAKA, T., SHODA, M., ISHIGOOKA, J., KASANUKI, H., & HAGIWARA, N. (2010). Prevalence and Persistence of Depression in Patients with Implantable Cardioverter Defibrillator: A 2‐year Longitudinal Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2010.02887.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.