The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial Fibrillation
Abstract
Background: A detailed appreciation of left atrial/pulmonary vein (LA/PV) anatomy may be important in improving the safety and success of catheter ablation (CA) for atrial fibrillation (AF). Objectives: The aim of this nonrandomized study was to determine the impact of computerized tomography (CT) image integration into a 3‐dimensional (3D) mapping system on the clinical outcome of patients undergoing CA for AF. Methods: Ninety‐four patients (age: 56 ± 10 years) with AF (paroxysmal 46, persistent 48) underwent wide encirclement of ipsilateral PV pairs using irrigated radiofrequency ablation with the endpoint of electrical isolation. Ablation was guided by 3D mapping alone (electroanatomic 24, noncontact 23) in 47 (3DM group) patients and by CT image integration (Cartomerge®) in 47 (CT group). In persistent AF, a combination of linear ablation and targeted ablation of complex fractionated electrograms was also performed. Results: Successful PV electrical isolation did not differ between the two groups. A significant reduction in fluoroscopy times was demonstrated in the CT group (49 ± 27 minutes vs 3DM group 62 ± 26 minutes, P = 0.03). Arrhythmia recurrence was reduced in the CT group (32% vs 51% in the 3DM group, P < 0.01). In 30 symptomatic patients (12 CT and 18 3DM), repeat procedures for AF (13 in 3DM and 5 CT, P ≤ 0.10) and AT (5 in 3DM and 7 CT, P = NS) were performed. Overall success on 7‐day monitor off antiarrhythmic drugs was achieved in 60% in the 3DM group when compared with 83% in the CT group (P < 0.05) at a follow‐up of 25 ± 5 weeks. Conclusion: CA for AF guided by CT integration was associated with reduced fluoroscopy times, arrhythmia recurrence, and increased restoration of sinus rhythm. Improved visualization of complex LA geometries might improve the safety and success of CA for AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.054 · Cited by 2,002
Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., Salvati, A., Dicandia, C., Mazzone, P., Santinelli, V., et al. (2000) · Circulation · doi:10.1161/01.cir.102.21.2619 · Cited by 1,358
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Packer, D., & Skanes, A. (2005) · Circulation · doi:10.1161/01.cir.0000157153.30978.67 · Cited by 1,305
Haïssaguerre, M., Jaïs, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., Hocini, M., Peng, J. T., Roudaut, R., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.12.1409 · Cited by 922
Oral, H., Scharf, C., Chugh, A., Hall, B., Cheung, P., Good, E., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Ouyang, F., Bänsch, D., Ernst, S., Schaumann, A., Hachiya, H., Chen, M., Chun, J., Falk, P., Khanedani, A., Antz, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000144459.37455.ee · Cited by 757
HAÏSSAGUERRE, M., HOCINI, M., SANDERS, P., SACHER, F., ROTTER, M., TAKAHASHI, Y., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00308.x · Cited by 755
Technique and Results of Linear Ablation at the Mitral Isthmus
Jaïs, P., Hocini, M., Hsu, L.-F., Sanders, P., Scavee, C., Weerasooriya, R., Macle, L., Raybaud, F., Garrigue, S., Shah, D. C., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146917.75041.58 · Cited by 751
HAÏSSAGUERRE, M., SANDERS, P., HOCINI, M., TAKAHASHI, Y., ROTTER, M., SACHER, F., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00307.x · Cited by 675
Sanders, P., Morton, J. B., Davidson, N. C., Spence, S. J., Vohra, J. K., Sparks, P. B., & Kalman, J. M. (2003) · Circulation · doi:10.1161/01.cir.0000090688.49283.67 · Cited by 622
Pre-existent left atrial scarring in patients undergoing pulmonary vein antrum isolation
Verma, A., Wazni, O. M., Marrouche, N. F., Martin, D. O., Kilicaslan, F., Minor, S., Schweikert, R. A., Saliba, W., Cummings, J., Burkhardt, J. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.035 · Cited by 595
Marrouche, N. F., Martin, D. O., Wazni, O., Gillinov, A. M., Klein, A., Bhargava, M., Saad, E., Bash, D., Yamada, H., Jaber, W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000070541.83326.15 · Cited by 512
Kato, R., Lickfett, L., Meininger, G., Dickfeld, T., Wu, R., Juang, G., Angkeow, P., LaCorte, J., Bluemke, D., Berger, R., et al. (2003) · Circulation · doi:10.1161/01.cir.0000061951.81767.4e · Cited by 492
Long‐Term Safety and Efficacy of Circumferential Ablation with Pulmonary Vein Isolation
CHEEMA, A., DONG, J., DALAL, D., VASAMREDDY, C. R., MARINE, J. E., HENRIKSON, C. A., SPRAGG, D., CHENG, A., NAZARIAN, S., SINHA, S., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00569.x · Cited by 453
Karch, M. R., Zrenner, B., Deisenhofer, I., Schreieck, J., Ndrepepa, G., Dong, J., Lamprecht, K., Barthel, P., Luciani, E., Schömig, A., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.491530 · Cited by 381
KISTLER, P. M., HO, S. Y., RAJAPPAN, K., MORPER, M., HARRIS, S., ABRAMS, D., SPORTON, S. C., & SCHILLING, R. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00981.x · Cited by 290
Self-citationRadiation Exposure During Catheter Ablation of Atrial Fibrillation
Lickfett, L., Mahesh, M., Vasamreddy, C., Bradley, D., Jayam, V., Eldadah, Z., Dickfeld, T., Kearney, D., Dalal, D., Lüderitz, B., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146952.49223.11 · Cited by 236
Dong, J., Calkins, H., Solomon, S. B., Lai, S., Dalal, D., Lardo, A., Brem, E., Preiss, A., Berger, R. D., Halperin, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.565200 · Cited by 233
DONG, J., DICKFELD, T., DALAL, D., CHEEMA, A., VASAMREDDY, C. R., HENRIKSON, C. A., MARINE, J. E., HALPERIN, H. R., BERGER, R. D., LIMA, J. A. C., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00425.x · Cited by 227
Ouyang, F., Ernst, S., Chun, J., Bänsch, D., Li, Y., Schaumann, A., Mavrakis, H., Liu, X., Deger, F. T., Schmidt, B., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.561183 · Cited by 219
KISTLER, P. M., EARLEY, M. J., HARRIS, S., ABRAMS, D., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00371.x · Cited by 182
Self-citationTops, L. F., Bax, J. J., Zeppenfeld, K., Jongbloed, M. R. M., Lamb, H. J., van der Wall, E. E., & Schalij, M. J. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.07.019 · Cited by 180
Jongbloed, M. R. M., Bax, J. J., Lamb, H. J., Dirksen, M. S., Zeppenfeld, K., van der Wall, E. E., Roos, A., & Schalij, M. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.040 · Cited by 136
Sanders, P., Jaïs, P., Hocini, M., Hsu, L., Scavée, C., Sacher, F., Rotter, M., Takahashi, Y., Pasquié, J., Shah, D. C., et al. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.03.072 · Cited by 132
Computed Tomography‐Fluoroscopy Image Integration‐Guided Catheter Ablation of Atrial Fibrillation
Sra, J. S., Narayan, G. A., Krum, D. P., Malloy, A., Cooley, R., Bhatia, A., Dhala, A. A., Blanck, Z., Nangia, V., & Akhtar, M. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00734.x · Cited by 131
Hocini, M., Sanders, P., Jaı̈s, P., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi096 · Cited by 107
Catheter ablation of permanent atrial fibrillation: medium term results
Earley, M. J. (2005) · Heart · doi:10.1136/hrt.2005.066969 · Cited by 47
Self-citationFynn, S. P., & Kalman, J. M. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00675.x · Cited by 33
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Metadata
- Authors
- KISTLER, P. M., RAJAPPAN, K., JAHNGIR, M., EARLEY, M. J., HARRIS, S., ABRAMS, D., GUPTA, D., LIEW, R., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2006-08-22
- Volume
- 17
- Issue
- 10
- Pages
- 1093-1101
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2034156327
- Cited by
- 272
- References
- 29
- FWCI
- 18.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.