The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Combined Multichannel Intraluminal Impedance and Manometry Clarifies Esophageal Function Abnormalities: Study in 350 Patients
Abstract
BACKGROUND: Combined multichannel intraluminal impedance and esophageal manometry (MII-EM) is a technique that uses an FDA-approved device allowing simultaneous evaluation of bolus transit (MII) in relation to pressure changes (EM). METHODS: During a 9-month period, beginning from July 2002 through March 2003, we prospectively performed combined MII-EM on all patients referred for esophageal function testing. Each patient received 10 liquid and 10 viscous swallows. Manometric findings were reported based on criteria described by Spechler and Castell for liquid swallows. MII findings were reported as having normal bolus transit if >/=80% (8/10) of liquid and >/=70% (7/10) of viscous swallows had complete bolus transit. RESULTS: Three-hundred fifty studies were evaluated from patients with a variety of symptoms having the following manometric diagnoses: normal manometry (125), achalasia (24), scleroderma (4), ineffective esophageal motility (IEM) (71), distal esophageal spasm (DES) (33), nutcracker esophagus (30), hypertensive lower esophageal sphincter (LES) (25), hypotensive LES (5), and poorly relaxing LES (33). None of the patients with achalasia and scleroderma had normal bolus transit. Fifty-one percent of patients with IEM and 55% of patients with DES had normal bolus transit while almost all (more than 95%) patients with normal esophageal manometry, nutcracker esophagus, poorly relaxing LES, hypertensive LES, and hypotensive LES had normal bolus transit. Dysphagia occurred most often in patients with incomplete bolus transit on MII testing. CONCLUSION: Esophageal body pressures primarily determine bolus transit with isolated LES abnormalities appearing to have little effect on esophageal function. MII clarifies functional abnormalities in patients with abnormal manometric studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Classification of oesophageal motility abnormalities
SPECHLER, S. J., & CASTELL, D. O. (2001) · Gut · doi:10.1136/gut.49.1.145 · Cited by 630
Self-citationEffect of peristaltic dysfunction on esophageal volume clearance
Kahrilas, P. J., Dodds, W. J., & Hogan, W. J. (1988) · Gastroenterology · doi:10.1016/0016-5085(88)90612-9 · Cited by 565
Richter, J. E., Wu, W. C., Johns, D. N., Blackwell, J. N., Nelson, J. L., Castell, J. A., & Castell, D. O. (1987) · Digestive Diseases and Sciences · doi:10.1007/bf01296157 · Cited by 535
Self-citationIntraluminal Multiple Electric Impedance Procedure for Measurement of Gastrointestinal Motility
Silny, J. (1991) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.1991.tb00061.x · Cited by 329
Fibbe, C., Layer, P., Keller, J., Strate, U., Emmermann, A., & Zornig, C. (2001) · Gastroenterology · doi:10.1053/gast.2001.25486 · Cited by 303
Leite, L. P., Johnston, B. T., Barrett, J., Castell, J. A., & Castell, D. O. (1997) · Digestive Diseases and Sciences · doi:10.1023/a:1018802908358 · Cited by 295
Self-citationRelevance of ineffective oesophageal motility during oesophageal acid clearance
Simrén, M., Silny, J., Holloway, R., Tack, J., Janssens, J., & Sifrim, D. (2003) · Gut · doi:10.1136/gut.52.6.784 · Cited by 231
Esophageal function testing using multichannel intraluminal impedance
Srinivasan, R., Vela, M. F., Katz, P. O., Tutuian, R. I., Castell, J. A., & Castell, D. O. (2001) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.2001.280.3.g457 · Cited by 142
Self-citationTutuian, R. I., Elton, J. P., Castell, D. O., et al. (2003) · Neurogastroenterology & Motility · doi:10.1046/j.1365-2982.2003.00387.x · Cited by 54
Self-citation
Cited by
Oesophageal high-resolution manometry: moving from research into clinical practice
Fox, M. R., & Bredenoord, A. J. (2008) · Gut · doi:10.1136/gut.2007.127993 · Cited by 384
Gullung, J. L., Hill, E. G., Castell, D. O., & Martin-Harris, B. (2012) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348941212101107 · Cited by 56
Self-citationOmari, T. I., Rommel, N., Szczesniak, M. M., Fuentealba, S., Dinning, P. G., Davidson, G. P., & Cook, I. J. (2006) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00011.2005 · Cited by 53
Artificial neural network classification of pharyngeal high‐resolution manometry with impedance data
Hoffman, M. R., Mielens, J. D., Omari, T. I., Rommel, N., Jiang, J. J., & McCulloch, T. M. (2013) · The Laryngoscope · doi:10.1002/lary.23655 · Cited by 34
Metadata
- Authors
- Tutuian, R., & Castell, D. O.
- Venue
- The American Journal of Gastroenterology
- Published
- 2004-06
- Volume
- 99
- Issue
- 6
- Pages
- 1011-1019
- ISSN
- 0002-9270 (ISSN-L)
- 1572-0241
- OpenAlex
- W1965818870
- Cited by
- 259
- References
- 9
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined Multichannel Intraluminal Impedance and Manometry Clarifies Esophageal Function Abnormalities: Study in 350 Patients. https://app.cochat.ai/papers/10.1111/j.1572-0241.2004.30035.x
- The paper
- Tutuian, R., & Castell, D. O. (2004). Combined Multichannel Intraluminal Impedance and Manometry Clarifies Esophageal Function Abnormalities: Study in 350 Patients. The American Journal of Gastroenterology. https://doi.org/10.1111/j.1572-0241.2004.30035.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.