Capsule Endoscopy Versus Computed Tomographic or Standard Angiography for the Diagnosis of Obscure Gastrointestinal Bleeding
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND AIMS: Capsule endoscopy (CE) is superior to push enteroscopy and small bowel barium radiography in detecting the source of obscure GI bleeding. We now compared whether CE has a superior diagnostic yield than CT angiography (CTA) or standard mesenteric angiography (ANGIO) in patients with obscure GI bleeding. METHODS: From June 2004 to October 2005, consecutive patients admitted for OGIB underwent both CTA and ANGIO, followed by CE, performed blindly by independent examiners within the next 7 days. The primary end point of the study was the diagnostic yield for each technique, defined as the frequency of detection of lesions with a high probability of bleeding. RESULTS: Twenty-eight patients (16 men and 12 women, mean age 74 +/- 2 yr) with OGIB (overt bleeding in 20 cases and chronic occult in 8) were prospectively evaluated. CTA or standard angiography could be performed in 25 of 28 patients (applicability 86%), because of contrast allergy (1 patient) and chronic renal failure (2 patients). A source of bleeding was detected by CE in a greater proportion of patients, 72% (18 of 25, 95% CI 50.6-87.9%), than CTA, 24% (6 of 25, 95% CI 9.4-45.1%, P= 0.005 vs CE), or ANGIO, 56% (14 of 25, 95% CI 34.9-75.6%, P= NS). Similarly, CE was able to diagnose 100% of patients diagnosed by CTA and 86% of patients diagnosed by ANGIO. Moreover, CE was positive in 12 of 19 (63%) negative cases on CTA and in 6 of 11 (55%) negative cases on ANGIO. As a result of the CE findings, therapeutic intervention was undertaken in 9 of 19 (47%) patients with positive results. CONCLUSION: CE detects more lesions than CTA or standard mesenteric angiography in patients with obscure GI bleeding and has a therapeutic impact in almost half of the patients with positive findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529786 · Cited by 4,332 · cited 1×
“Kappa values are between 0 and 1, 0 representing absence of concordance and 1 complete concordance, and their corresponding 95% confidence intervals (95% CI) were estimated (27).”
BackgroundPennazio, M., Santucci, R., Rondonotti, E., Abbiati, C., Beccari, G., Rossini, F. P., & De Franchis, R. (2004) · Gastroenterology · doi:10.1053/j.gastro.2003.11.057 · Cited by 918
Costamagna, G., Shah, S. K., Riccioni, M. E., Foschia, F., Mutignani, M., Perri, V., Vecchioli, A., Brizi, M. G., Picciocchi, A., & Marano, P. (2002) · Gastroenterology · doi:10.1053/gast.2002.35988 · Cited by 796 · cited 1×
“Several studies have now shown that capsule endoscopy (CE) is superior to small bowel barium radiography, enteroclysis, and push enteroscopy”
BackgroundYamamoto, H., Kita, H., Sunada, K., Hayashi, Y., Sato, H., Yano, T., Iwamoto, M., Sekine, Y., Miyata, T., Kuno, A., et al. (2004) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(04)00453-7 · Cited by 678 · cited 1×
“Now, double-balloon enteroscopy (DBE) allows for the endoscopic examination of the entire small bowel with the extra advantage of hemostatic intervention capability (38, 39).”
BackgroundTriester, S. L., Leighton, J. A., Leontiadis, G. I., Fleischer, D. E., Hara, A. K., Heigh, R. I., Shiff, A. D., & Sharma, V. K. (2005) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2005.00274.x · Cited by 648
Ell, C., Remke, S., May, A., Helou, L., Henrich, R., & Mayer, G. (2002) · Endoscopy · doi:10.1055/s-2002-33446 · Cited by 635 · cited 1×
“Previous studies found that the diagnostic yield of CE in patients with OGIB is superior to that of conventional diagnostic workup, including angiography (19, 24).”
ResultZuckerman, G. R., Gyawali, C. P., Askin, M. P., & Lewis, B. S. (2000) · Gastroenterology · doi:10.1016/s0016-5085(00)70430-6 · Cited by 501
Mylonaki, M., Fritscher-Ravens, A., & Swain, P. (2003) · Gut · doi:10.1136/gut.52.8.1122 · Cited by 477
Appleyard, M. N., Fireman, Z., Glukhovsky, A., Jacob, H., Shreiver, R., Kadirkamanathan, S., Lavy, A., Lewkowicz, S., Scapa, E., Shofti, R., et al. (2000) · Gastroenterology · doi:10.1053/gast.2000.20844 · Cited by 437 · cited 1×
“The above examinations were carried out as described in detail elsewhere: CTA (16), selective angiography of the celiac trunk and mesenteric vessels (16), and CE using the Given Imaging M2A video capsule (18).”
MethodMay, A., Nachbar, L., & Ell, C. (2005) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(05)01586-5 · Cited by 378 · cited 1×
“Now, double-balloon enteroscopy (DBE) allows for the endoscopic examination of the entire small bowel with the extra advantage of hemostatic intervention capability (38, 39).”
BackgroundA Pooled Analysis to Evaluate Results of Capsule Endoscopy Trials
Lewis, B. S., Eisen, G. M., & Friedman, S. (2005) · Endoscopy · doi:10.1055/s-2005-870353 · Cited by 289 · cited 1×
“However, CE is not a perfect technique and overall a 10p miss rate has been reported”
BackgroundJunquera, F., Feu, F., Papo, M., Videla, S., Armengol, J. R., Bordas, J. M., Saperas, E., Piqué, J. M., & Malagelada, J.-R. (2001) · Gastroenterology · doi:10.1053/gast.2001.28650 · Cited by 249
Self-citationDetection of Active Colonic Hemorrhage with Use of Helical CT: Findings in a Swine Model
Kuhle, W. G., & Sheiman, R. G. (2003) · Radiology · doi:10.1148/radiol.2283020756 · Cited by 242 · cited 1×
“However, it is likely that suboptimal and poorly distended bowel segments that make detection of subtle vascular lesions in the small bowel challenging”
BackgroundMeta‐analysis: capsule enteroscopy vs. conventional modalities in diagnosis of small bowel diseases
MARMO, R., ROTONDANO, G., PISCOPO, R., BIANCO, M. A., & CIPOLLETTA, L. (2005) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2005.02625.x · Cited by 209 · cited 1×
“obscure gastrointestinal hemorrhage (25, 26).”
Diagnostic Yield of Wireless Capsule Enteroscopy in Comparison with Computed Tomography Enteroclysis
Voderholzer, W., Ortner, M., Rogalla, P., Beinhölzl, J., & Lochs, H. (2003) · Endoscopy · doi:10.1055/s-2003-44583 · Cited by 190
Mata, A., Bordas, J., Feu, F., Ginés, À., Pellisé, M., Fernández‐Esparrach, G., Balaguer, F., Pique, J. M., & Llach, J. (2004) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2004.02067.x · Cited by 168
Helical CT in acute lower gastrointestinal bleeding
Ernst, O., Bulois, P., Saint-Drenant, S., Leroy, C., Paris, J.-C., & Sergent, G. (2003) · European Radiology · doi:10.1007/s00330-002-1442-y · Cited by 162
Neu, B., Ell, C., May, A., Schmid, E., Riemann, J. F., Hagenmüller, F., Keuchel, M., Soehendra, N., Seitz, U., Meining, A. G., et al. (2005) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2005.41649.x · Cited by 104 · cited 1×
“Previous studies found that the diagnostic yield of CE in patients with OGIB is superior to that of conventional diagnostic workup, including angiography (19, 24).”
ResultRollins, E. S., Picus, D., Hicks, M. E., Darcy, M. D., Bower, B. L., & Kleinhoffer, M. A. (1991) · American Journal of Roentgenology · doi:10.2214/ajr.156.2.1898820 · Cited by 93
Helicobacter pylori infection and long term proton pump inhibitor therapy
McColl, K. E. L. (2003) · Gut · doi:10.1136/gut.53.1.5 · Cited by 36
Cited by
Pennazio, M., Spada, C., Eliakim, R., Keuchel, M., May, A., Mulder, C., Rondonotti, E., Adler, S., Albert, J., Baltes, P., et al. (2015) · Endoscopy · doi:10.1055/s-0034-1391855 · Cited by 894
Clinical Practice Guidelines for the Use of Video Capsule Endoscopy
Enns, R. A., Hookey, L., Armstrong, D., Bernstein, C. N., Heitman, S. J., Teshima, C., Leontiadis, G. I., Tse, F., & Sadowski, D. (2017) · Gastroenterology · doi:10.1053/j.gastro.2016.12.032 · Cited by 400
Pennazio, M., Rondonotti, E., Despott, E. J., Dray, X., Keuchel, M., Moreels, T., Sanders, D. S., Spada, C., Carretero, C., Cortegoso Valdivia, P., et al. (2023) · Endoscopy · doi:10.1055/a-1973-3796 · Cited by 331
Wang, A., Banerjee, S., Barth, B. A., Bhat, Y. M., Chauhan, S., Gottlieb, K. T., Konda, V., Maple, J. T., Murad, F., Pfau, P. R., et al. (2013) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2013.06.026 · Cited by 327
Oakland, K., Chadwick, G., East, J. E., Guy, R., Humphries, A., Jairath, V., McPherson, S., Metzner, M., Morris, A. J., Murphy, M. F., et al. (2019) · Gut · doi:10.1136/gutjnl-2018-317807 · Cited by 324
Metadata
- Authors
- Saperas, E., Dot, J., Videla, S., Alvarez-Castells, A., Perez-Lafuente, M., Armengol, J. R., & Malagelada, J.-R.
- Venue
- The American Journal of Gastroenterology
- Published
- 2007-04
- Volume
- 102
- Issue
- 4
- Pages
- 731-737
- ISSN
- 0002-9270 (ISSN-L)
- 1572-0241
- OpenAlex
- W2052154117
- Cited by
- 193
- References
- 20
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.