Early osseointegration to hydrophilic and hydrophobic implant surfaces in humans: Early osseointegration on implant surfaces
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the rate and degree of osseointegration at chemically modified moderately rough, hydrophilic (SLActive) and moderately rough, hydrophobic (SLA) implant surfaces during early phases of healing in a human model. MATERIAL AND METHODS: The devices used for this study of early healing were 4 mm long and 2.8 mm in diameter and had either an SLActive chemically modified or a moderately rough SLA surface configuration. These devices were surgically installed into the retro-molar area of 49 human volunteers and retrieved after 7, 14, 28 and 42 days of submerged healing. A 5.2-mm-long specially designed trephine with a 4.9 mm inside diameter, allowing the circumferential sampling of 1 mm tissue together with the device was applied. Histologic ground sections were prepared and histometric analyses of the tissue components (i.e. old bone, new bone, bone debris and soft tissue) in contact with the device surfaces were performed. RESULTS: All device sites healed uneventfully. All device surfaces were partially coated with bone debris. A significant fraction of this bone matrix coating became increasingly covered with newly formed bone. The process of new bone formation started already during the first week in the trabecular regions and increased gradually up to 42 days. The percentage of direct contact between newly formed bone and the device (bone-to-implant contact) after 2 and 4 weeks was more pronounced adjacent to the SLActive than to the SLA surface (14.8% vs. 12.2% and 48.3% vs. 32.4%, respectively), but after 42 days, these differences were no longer evident (61.6% vs. 61.5%). CONCLUSION: While healing showed similar characteristics with bone resorptive and appositional events for both SLActive and SLA surfaces between 7 and 42 days, the degree of osseointegration after 2 and 4 weeks was superior for the SLActive compared with the SLA surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Enhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Buser, D., Broggini, N., Wieland, M., Schenk, R. K., Denzer, A. J., Cochran, D. L., Hoffmann, B., Lussi, A., & Steinemann, S. G. (2004) · Journal of Dental Research · doi:10.1177/154405910408300704 · Cited by 1,202
Martin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111
High surface energy enhances cell response to titanium substrate microstructure
Zhao, G., Schwartz, Z., Wieland, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D. L., & Boyan, B. D. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30320 · Cited by 922
Cochran, D. L., Schenk, R. K., Lussi, A., Higginbottom, F. L., & Buser, D. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199804)40:1<1::aid-jbm1>3.0.co;2-q · Cited by 690
De novo alveolar bone formation adjacent to endosseous implants: A model study in the dog
Berglundh, T., Abrahamsson, I., Lang, N. P., & Lindhe, J. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.00972.x · Cited by 689
Self-citationCochran, D. L., Buser, D., Ten Bruggenkate, C. M., Weingart, D., Taylor, T. M., Bernard, J., Peters, F., & Simpson, J. P. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130204.x · Cited by 568
Kieswetter, K., Schwartz, Z., Hummert, T. W., Cochran, D. L., Simpson, J., Dean, D. D., & Boyan, B. D. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199609)32:1<55::aid-jbm7>3.0.co;2-o · Cited by 565
Brown, W. A. B. (1985) · FEBS Letters · doi:10.1016/0014-5793(85)81367-3 · Cited by 495
Cited by
Review on titanium and titanium based alloys as biomaterials for orthopaedic applications
Kaur, M., & Singh, K. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.064 · Cited by 1,451
A review on the wettability of dental implant surfaces II: Biological and clinical aspects
Gittens, R. A., Scheideler, L., Rupp, F., Hyzy, S. L., Geis-Gerstorfer, J., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.032 · Cited by 849
Surface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
Bosshardt, D. D., Chappuis, V., & Buser, D. (2017) · Periodontology 2000 · doi:10.1111/prd.12179 · Cited by 574
Self-citationNano-scale modification of titanium implant surfaces to enhance osseointegration
Souza, J. C. M., Sordi, M. B., Kanazawa, M., Ravindran, S., Henriques, B., Silva, F. S., Aparicio, C., & Cooper, L. F. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.045 · Cited by 544
On osseointegration in relation to implant surfaces
Albrektsson, T., & Wennerberg, A. (2019) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12742 · Cited by 361
Chen, Z., Wu, C., Gu, W., Klein, T., Crawford, R., & Xiao, Y. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.014 · Cited by 324
Osseointegration – communication of cells
Terheyden, H., Lang, N. P., Bierbaum, S., & Stadlinger, B. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02327.x · Cited by 265
Self-citationAraujo, M. G., & Lindhe, J. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0424 · Cited by 173
Donos, N., Hamlet, S., Lang, N. P., Salvi, G. E., Huynh-Ba, G., Bosshardt, D. D., & Ivanovski, S. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02113.x · Cited by 166
Self-citationTemporal sequence of hard and soft tissue healing around titanium dental implants
Salvi, G. E., Bosshardt, D. D., Lang, N. P., Abrahamsson, I., Berglundh, T., Lindhe, J., Ivanovski, S., & Donos, N. (2015) · Periodontology 2000 · doi:10.1111/prd.12054 · Cited by 158
Self-citationHamlet, S., Alfarsi, M., George, R., & Ivanovski, S. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02325.x · Cited by 150
Self-citation
Metadata
- Authors
- Lang, N. P., Salvi, G. E., Huynh-Ba, G., Ivanovski, S., Donos, N., & Bosshardt, D. D.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2011-03-09
- Volume
- 22
- Issue
- 4
- Pages
- 349-356
- ISSN
- 0905-7161 (ISSN-L)
- OpenAlex
- W1849295147
- Cited by
- 466
- References
- 20
- FWCI
- 26.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.