Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Epidemiologic research into the causes of non-specific symptoms among office workers has produced a variety of conflicting findings which are difficult to synthesize. This paper first discusses methodologic issues important in the interpretation of epidemiologic studies, and then reviews the findings of 32 studies of 37 factors potentially related to office worker symptoms. Among environmental factors assessed, there were generally consistent findings associating increased symptoms with air-conditioning, carpets, more workers in a space, VDT use, and ventilation rates at or below 10 liters/second/person. Studies with particularly strong designs found decreased symptoms associated with low ventilation rate, short-term humidification, negative ionization, and improved office cleaning, although studies reviewed showed little consistency of findings for humidification and ionization. Relatively strong studies associated high temperature and low relative humidity with increased symptoms, whereas less strong studies were not consistent. Among personal factors assessed, there were generally consistent findings associating increased symptoms with female gender, job stress/dissatisfaction, and allergies/asthma. For other environmental or personal factors assessed, findings were too inconsistent or sparse for current interpretation, and there were no findings from strong studies. Overall evidence suggested that work related symptoms among office workers were relatively common, and that some of these symptoms represented preventable physiologic effects of environmental exposures or conditions. Future research on this problem should include blind experimental and case-control studies, using improved measurements of both environmental exposures and health outcomes
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1979) · Medical Entomology and Zoology · Cited by 11,252
Journal of Occupational Medicine
Norman, L. G. (1959) · Occupational and Environmental Medicine · doi:10.1136/oem.16.4.332-a · Cited by 2,294
The New England journal of medicine
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92577-1 · Cited by 465
Damp housing, mould growth, and symptomatic health state.
Platt, S. D., Martin, C. J., Hunt, S. M., & Lewis, C. W. (1989) · BMJ · doi:10.1136/bmj.298.6689.1673 · Cited by 457
The sick building syndrome: prevalence studies.
Finnegan, M. J., Pickering, C. A., & Burge, P. S. (1984) · BMJ · doi:10.1136/bmj.289.6458.1573 · Cited by 373
Volatile Organic Compounds, Indoor Air Quality and Health
Molhave, L. (1991) · Indoor Air · doi:10.1111/j.1600-0668.1991.00001.x · Cited by 315
Mendell, M. J., & Smith, A. H. (1990) · American Journal of Public Health · doi:10.2105/ajph.80.10.1193 · Cited by 258
Self-citationThe journal of allergy and clinical immunology
(2004) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(04)00789-4 · Cited by 257
Fungi as contaminants in indoor air
Miller, J. D. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90404-9 · Cited by 236
Skov, P., Valbjorn, O., & Pedersen, B. V. (1989) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.1851 · Cited by 228
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Self-citationAllen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationOccupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Redlich, C. A., Sparer, J., & Cullen, M. R. (1997) · The Lancet · doi:10.1016/s0140-6736(96)07220-0 · Cited by 759
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
“(2002), and Mendell (1993). In addition, a further literature search was conducted according to the following criteria and procedures.”
BackgroundResultInfluentialWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Fisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 557
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 549
The adaptive model of thermal comfort and energy conservation in the built environment
de Dear, R., & Schiller Brager, G. (2001) · International Journal of Biometeorology · doi:10.1007/s004840100093 · Cited by 516
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Influence of indoor environmental quality on human health and productivity - A review
Mujan, I., Anđelković, A. S., Munćan, V., Kljajić, M., & Ružić, D. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.01.307 · Cited by 405
Tham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
The impact of thermal environment on occupant IEQ perception and productivity
Geng, Y., Ji, W., Lin, B., & Zhu, Y. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.022 · Cited by 388
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Indoor Mold, Toxigenic Fungi, and Stachybotrys chartarum: Infectious Disease Perspective
Kuhn, D. M., & Ghannoum, M. A. (2003) · Clinical Microbiology Reviews · doi:10.1128/cmr.16.1.144-172.2003 · Cited by 352
APTE, M. G., FISK, W. J., & DAISEY, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Risk in cleaning: chemical and physical exposure
Wolkoff, P., Schneider, T., Kildesø, J., Degerth, R., Jaroszewski, M., & Schunk, H. (1998) · Science of The Total Environment · doi:10.1016/s0048-9697(98)00110-7 · Cited by 287
Seppänen, O., & Fisk, W. J. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01111.x · Cited by 277
Persily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249
“For office buildings, research has shown that ventilation rates above 10 L/s per person are associated with lower rates of sick building syndrome (SBS) symptoms [29].”
BackgroundSummary of human responses to ventilation
Seppanen, O. A., & Fisk, W. J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00279.x · Cited by 249
“Additionally, the presence or absence of statisticallysignificant associations of HVAC system types with outcomes is illustrated graphically within the tables using an adaptation of the format of ( Mendell, 1993 ).”
MethodHodgson, M. J., Morey, P., Leung, W.-Y., Morrow, L., Miller, D., Jarvis, B. B., Robbins, H., Halsey, J. F., & Storey, E. (1998) · Journal of Occupational & Environmental Medicine · doi:10.1097/00043764-199803000-00006 · Cited by 230
Mendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229
Self-citationWitterseh, T., Wyon, D. P., & Clausen, G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00305.x · Cited by 227
Volatile Organic Compounds Sources, Measurements, Emissions, and the Impact on Indoor Air Quality
Wolkoff, P. (1995) · Indoor Air · doi:10.1111/j.1600-0668.1995.tb00017.x · Cited by 210
An update on sick building syndrome
Norbäck, D. (2009) · Current Opinion in Allergy & Clinical Immunology · doi:10.1097/aci.0b013e32831f8f08 · Cited by 197
I NDOOR A IR Q UALITY F ACTORS IN D ESIGNING A H EALTHY B UILDING
Spengler, J. D., & Chen, Q. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.567 · Cited by 194
“Mendell reviewed these and other studies in an attempt to identify common identifying factors (20).”
BackgroundSahlberg, B., Gunnbjörnsdottir, M., Soon, A., Jogi, R., Gislason, T., Wieslander, G., Janson, C., & Norback, D. (2013) · Science of The Total Environment · doi:10.1016/j.scitotenv.2012.10.114 · Cited by 189
Are We Measuring the Relevant Indoor Pollutants?
Wolkoff, P., Clausen, P. A., Jensen, B., Nielsen, G. D., & Wilkins, C. K. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-2-00003.x · Cited by 180
Carrer, P., Wargocki, P., Fanetti, A., Bischof, W., De Oliveira Fernandes, E., Hartmann, T., Kephalopoulos, S., Palkonen, S., & Seppänen, O. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.08.011 · Cited by 172
Indoor climate, psychosocial work environment and symptoms in open-plan offices
Pejtersen, J., Allermann, L., Kristensen, T. S., & Poulsen, O. M. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00444.x · Cited by 170
“The findings are consistent with the few studies that have included number of workers in the space in their analysis (Chao et al., 2003; Mendell, 1993, 1993).”
BackgroundResultMenzies, D., & Bourbeau, J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711203372107 · Cited by 167
Bluyssen, P. M., Roda, C., Mandin, C., Fossati, S., Carrer, P., de Kluizenaar, Y., Mihucz, V. G., de Oliveira Fernandes, E., & Bartzis, J. (2016) · Indoor Air · doi:10.1111/ina.12196 · Cited by 167
Erdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147
Some Quantitative Relations between Indoor Environmental Quality and Work Performance or Health
Seppänen, O. A., & Fisk, W. (2006) · HVAC&R Research · doi:10.1080/10789669.2006.10391446 · Cited by 53
Metadata
- Authors
- Mendell, M. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1993-12
- Volume
- 3
- Issue
- 4
- Pages
- 227-236
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2167058705
- Cited by
- 284
- References
- 24
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.