Relationship between outdoor and indoor air quality in eight French schools
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
UNLABELLED: In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO(2)), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO(2) concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO(2) indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size. PRACTICAL IMPLICATIONS: Assessing children's total exposure requires the knowledge of outdoor and indoor air contaminant concentrations. The study presented here provides data on compared outdoor and indoor concentration levels in school buildings, as well as information on the parameters influencing the relationship between outdoor and indoor air quality. It may be used as a basis for estimating indoor concentrations from outdoor concentrations data, or as a first step in designing buildings sheltering children against atmospheric pollution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Ozone in Indoor Environments: Concentration and Chemistry
WESCHLER, C. J. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004269.x · Cited by 758
Activity patterns of Californians: Use of and proximity to indoor pollutant sources
Jenkins, P. L., Phillips, T. J., Mulberg, E. J., & Hui, S. P. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90402-7 · Cited by 415
Indoor and outdoor air quality investigation at schools in Hong Kong
Lee, S. C., & Chang, M. (2000) · Chemosphere · doi:10.1016/s0045-6535(99)00396-3 · Cited by 356
Baek, S.-O., Kim, Y.-S., & Perry, R. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(96)00215-4 · Cited by 298
Modeling pollutant penetration across building envelopes
Liu, D.-L., & Nazaroff, W. W. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00218-7 · Cited by 272
Particle deposition indoors: a review
Lai, A. C. K. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01159.x · Cited by 226
Removal of reactive gases at indoor surfaces: Combining mass transport and surface kinetics
Cano-Ruiz, J. A., Kong, D., Balas, R. B., & Nazaroff, W. W. (1993) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(93)90276-5 · Cited by 180
K. Koponen, I., Asmi, A., Keronen, P., Puhto, K., & Kulmala, M. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00338-1 · Cited by 162
Cited by
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Chen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
Outdoor-indoor air pollution in urban environment: challenges and opportunity
Leung, D. Y. C. (2015) · Frontiers in Environmental Science · doi:10.3389/fenvs.2014.00069 · Cited by 401
Sadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104908 · Cited by 375
Fromme, H., Twardella, D., Dietrich, S., Heitmann, D., Schierl, R., Liebl, B., & Rüden, H. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.08.053 · Cited by 359
The dichotomy of relative humidity on indoor air quality
Wolkoff, P., & Kjærgaard, S. K. (2007) · Environment International · doi:10.1016/j.envint.2007.04.004 · Cited by 260
Children exposure to atmospheric particles in indoor of Lisbon primary schools
Almeida, S. M., Canha, N., Silva, A., Freitas, M. D. C., Pegas, P., Alves, C., Evtyugina, M., & Pio, C. A. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.11.052 · Cited by 256
Characterization of indoor air quality in primary schools in Antwerp, Belgium
Stranger, M., Potgieter-Vermaak, S. S., & Van Grieken, R. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00545.x · Cited by 198
Bell, M. L., & Dominici, F. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm396 · Cited by 183
“Given the highly reactive nature of ozone, indoor concentrations can be much lower than ambient levels, and ventilation characteristics can appreciably affect indoor/outdoor ratios of ozone levels (13, 14).”
BackgroundWichmann, J., Lind, T., Nilsson, M. A.-M., & Bellander, T. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.08.023 · Cited by 182
What do we know about indoor air quality in school classrooms? A critical review of the literature
Chatzidiakou, L., Mumovic, D., & Summerfield, A. J. (2012) · Intelligent Buildings International · doi:10.1080/17508975.2012.725530 · Cited by 182
“2000) NO2 200 mg/m 3 1-hour Blondeau et al. (2005) 5.9 (3.3–8.46) 34.8+5.2 mg/m(3) respiratory symptoms, allergy exacerbations (Janssen et al. 2003) 40 mg/m(3) Annual Blondeau et al. (2005)winter 18.”
BackgroundInfluentialde Gennaro, G., Dambruoso, P. R., Loiotile, A. D., Di Gilio, A., Giungato, P., Tutino, M., Marzocca, A., Mazzone, A., Palmisani, J., & Porcelli, F. (2014) · Environmental Chemistry Letters · doi:10.1007/s10311-014-0470-6 · Cited by 178
Synthesis of activated carbon from food waste
Kosheleva, R. I., Mitropoulos, A. C., & Kyzas, G. Z. (2019) · Environmental Chemistry Letters · doi:10.1007/s10311-018-0817-5 · Cited by 163
Guo, H., Morawska, L., He, C., & Gilbert, D. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.09.070 · Cited by 161
“…how well the building envelope protects against outdoor particulate matter; or how well the building ventilation system disperses the indoor-generated particles (e.g. Lee et al., 2002; Chao et al., 2003; Li and Chen, 2003; Morawska et al., 2001, 2003; Blondeau et al., 2005; Poupard et al., 2005).”
BackgroundLong-Term Exposure to Traffic-Related Air Pollution and Cardiovascular Mortality
Chen, H., Goldberg, M. S., Burnett, R. T., Jerrett, M., Wheeler, A. J., & Villeneuve, P. J. (2013) · Epidemiology · doi:10.1097/ede.0b013e318276c005 · Cited by 159
Pegas, P. N., Nunes, T., Alves, C. A., Silva, J. R., Vieira, S. L. A., Caseiro, A., & Pio, C. A. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.03.059 · Cited by 102
Characterization of coarse particulate matter in school gyms
Braniš, M., & Šafránek, J. (2011) · Environmental Research · doi:10.1016/j.envres.2011.03.010 · Cited by 86
Metadata
- Authors
- Blondeau, P., Iordache, V., Poupard, O., Genin, D., & Allard, F.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2005-01
- Volume
- 15
- Issue
- 1
- Pages
- 2-12
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2049525034
- Cited by
- 317
- References
- 13
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.