Photoplethysmography system for blood pulsation detection in unloaded artery conditions

Grabovskis, A., Marcinkevics, Z., Rubenis, O., Rubins, U., Lusa, V.·2012·SPIE Proceedings

Abstract

Photoplethysmography (PPG) is an optical method of blood pulsation recording and has been extensively studied for decades. Recently PPG is widely used in the medical equipment for patient monitoring and in laboratories for research and physiological studies. In spite of the technological progress in the field of medical equipment, there are no generally accepted standards for clinical PPG measurements up to date. One of the most important factors affecting PPG waveform is the contact pressure between tissue and PPG probe. The aim of the current study was to develop and evaluate a system for software-assisted PPG signal acquisition from the unloaded artery. Novel PPG waveform derived Optimal Pressure Parameter (OPP) has been proposed as the reliable indicator of unloaded artery condition. We affirm that PPG measurements provided in balanced transmural arterial pressure conditions might serve as a reference for the unification of contact manner optical plethysmography methods. It is a step forward towards the standardization of the PPG methodology, and showed that the maximal value of the OPP, obtained in the particular experimental trial, indicates the optimal PPG probe contact pressure at that moment. Our developed system has been validated in the experimental series and showed the possibility of determining the correct PPG contact pressure value with high repeatability. It is concluded that this system can provide the necessary feedback to perform reliable PPG signal acquisition from the unloaded conduit artery.

Integrity signals

Registry

Crossref · 10.1117/12.922649

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • With an applied pressure range of 0-15 kPa, there was a variation of over 300 percent in the b/a ratio; when an optimal pressure was reached, the variation coefficient dropped to less than 5 percent.

    “Grabovskis et al. reported with an applied pressure range of 0–15 kPa, there was a variation of over 300 percent in the b/a ratio [209]. When an optimal pressure was reached, the variation coefficient dropped to less than 5 percent.”
  • Grabovskis et al. reported a less than 3% coefficient of variation within a subject at the single measurement site when determining the optimal pressure needed to determine an unloaded artery.

    “Grabovskis et al. reported a less than 3% coefficient of variation within a subject at the single measurement site when determining the optimal pressure needed to determine an unloaded artery.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Grabovskis, A., Marcinkevics, Z., Rubenis, O., Rubins, U., & Lusa, V.
Affiliations
University of Latvia (LV)
Venue
SPIE Proceedings
Publisher
SPIE
Published
2012-06-01
Volume
8427
Pages
84270L
ISSN
0277-786X (ISSN-L)
OpenAlex
W2077564187
Cited by
11
References
15
Citations by year
2021: 2 · 2019: 2 · 2015: 1 · 2014: 3 · 2013: 2 · 2012: 1
FWCI
4.81
Type
conference paper
Language
en
Open access
closed
Locations
Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review