Plasma Protein Adsorption: The Big Twelvea
The DOI matches its Crossref record.
Abstract
We have discussed the general principles of protein adsorption at solid-liquid interfaces from single component and multicomponent solutions, based on qualitative kinetic models that include mass transport considerations, initial interaction energies, surface-dependent conformational changes, and possible desorption processes. We have surveyed plasma protein components greater than one milligram per milliliter in concentration, which we call "The Big Twelve." We considered their size, concentration, diffusion coefficient, structure and function, and methods of estimating their "surface denaturability" by using bulk solution measures of denaturation and conformational change. We have suggested that the role of the carbohydrate moieties in plasma proteins may have some bearing on their adsorption properties. We further suggest that lipoproteins, because of their lipid phase transition and conformational lability at body temperature, may tend to dominate the adsorption process, particularly on mobile elastomeric polymer surfaces. We suggest that detailed consideration of the structure and characteristics of each of the proteins involved is necessary in order to begin to understand plasma adsorption processes. Detailed characterization and understanding of the solid surface in the aqueous and protein environments are also required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Understanding protein adsorption phenomena at solid surfaces
Rabe, M., Verdes, D., & Seeger, S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.007 · Cited by 1,664
Conductive Polymers: Opportunities and Challenges in Biomedical Applications
Nezakati, T., Seifalian, A., Tan, A., & Seifalian, A. M. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00275 · Cited by 977
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Inflammatory Responses to Biomaterials
Tang, L., & Eaton, J. W. (1995) · American Journal of Clinical Pathology · doi:10.1093/ajcp/103.4.466 · Cited by 481
Chonn, A., Semple, S. C., & Cullis, P. R. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)37026-7 · Cited by 460
Cellular and Molecular Dynamics in the Foreign Body Reaction
Luttikhuizen, D. T., Harmsen, M. C., & Luyn, M. J. A. V. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1955 · Cited by 396
Fetuin-A Regulation of Calcified Matrix Metabolism
Jahnen-Dechent, W., Heiss, A., Schäfer, C., & Ketteler, M. (2011) · Circulation Research · doi:10.1161/circresaha.110.234260 · Cited by 385
Surfaces that resist bioadhesion
Kingshott, P., & Griesser, H. J. (1999) · Current Opinion in Solid State and Materials Science · doi:10.1016/s1359-0286(99)00018-2 · Cited by 374
Polymers in cell encapsulation from an enveloped cell perspective
de Vos, P., Lazarjani, H. A., Poncelet, D., & Faas, M. M. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.005 · Cited by 298
“Protein adsorption is minimal with PEG at a degree of polymerization (DP) above 100 [244].”
Engineering biomaterials to integrate and heal: The biocompatibility paradigm shifts
Bryers, J. D., Giachelli, C. M., & Ratner, B. D. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24559 · Cited by 271
“Albumin, Fg, and immunoglobulin (IgG) have been shown to predominate at the tissue–material interface of many implanted biomaterials, including poly(ethylene terephthalate) (PET), expanded poly(tetrafluoroethylene) (ePTFE), poly(urethanes) (PU), and poly(ethylene) (PE) (Andrade and Hlady, 1987; Anderson et al., 1990;…”
BackgroundMolecular determinants of acute inflammatory responses to biomaterials.
Tang, L., Ugarova, T. P., Plow, E. F., & Eaton, J. W. (1996) · Journal of Clinical Investigation · doi:10.1172/jci118549 · Cited by 207
“, polytetrafluoroethylene, polydimethylsiloxane, polyurethane, polyethylene, and Dacron) three host proteins predominate: albumin, IgG, and fibrinogen (16, 17).”
Nie, C., Ma, L., Xia, Y., He, C., Deng, J., Wang, L., Cheng, C., Sun, S., & Zhao, C. (2015) · Journal of Membrane Science · doi:10.1016/j.memsci.2014.11.005 · Cited by 168
A wettability gradient as a tool to study protein adsorption and cell adhesion on polymer surfaces
Lee, J. H., & Lee, H. B. (1993) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856293x00131 · Cited by 166
Chonn, A., Semple, S. C., & Cullis, P. R. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.43.25845 · Cited by 165
Significance of Nano- and Microtopography for Cell-Surface Interactions in Orthopaedic Implants
Jäger, M., Zilkens, C., Zanger, K., & Krauspe, R. (2007) · Journal of Biomedicine and Biotechnology · doi:10.1155/2007/69036 · Cited by 159
“The first step after exposure of any biomaterial to a biological environment results in the rapid adsorption of proteins to its surface [34].”
BackgroundImplantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Foreign body response to synthetic polymer biomaterials and the role of adaptive immunity
Kyriakides, T. R., Kim, H.-J., Zheng, C., Harkins, L., Tao, W., & Deschenes, E. (2022) · Biomedical Materials · doi:10.1088/1748-605x/ac5574 · Cited by 106
“Commonly adsorbed proteins include albumin, immunoglobulin, complement, fibrinogen, fibronectin, and others [48].”
Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles
Cameron, T., Liinamaa, T. L., Loeb, G. E., & Richmond, F. J. R. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704871 · Cited by 53
Shi, Z.-Q., Ji, H.-F., Yu, H.-C., Huang, X.-L., Zhao, W.-F., Sun, S.-D., & Zhao, C.-S. (2016) · Colloid and Polymer Science · doi:10.1007/s00396-015-3801-7 · Cited by 41
“When a material surface contacts with blood, protein adsorption at the interface is considered to be the first stage, which may activate the intrinsic pathway of coagulation cascade and promote the formation of thrombus [46].”
BackgroundBiotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Metadata
- Authors
- ANDRADE, J. D., & HLADY, V.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 1987-12
- Volume
- 516
- Issue
- 1
- Pages
- 158-172
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W1991505001
- Cited by
- 292
- References
- 0
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.