CoChat

Performance of two new, automated chemiluminescence assay panels for anticardiolipin and anti‐beta2‐glycoprotein I antibodies in the laboratory diagnosis of the antiphospholipid syndrome

Open access
Van Hoecke, F., Persijn, L., Decavele, A.‐S., Devreese, K. · 2012 · International Journal of Laboratory Hematology
Cited by 56

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Summary: Introduction: Anticardiolipin (aCL) and anti‐β2‐glycoprotein I (aβ 2 GPI) antibodies are two of the three laboratory criteria for antiphospholipid syndrome (APS). All assays for antiphospholipid antibodies (aPL), coagulation assays as well as ELISAs, show methodological shortcomings, which makes the search for better assays everlasting. The purpose of this study was to investigate the diagnostic performance of two new, fully automated systems (Z enit RA and H emos IL A custar) applying chemiluminescent technology for aPL detection. Methods: The study cohort consisted of a patient population presenting with thrombosis. In such patient population, the demonstration of aPL determines whether a patient has APS or not with implications for treatment. One hundred and twenty‐four patients with thrombotic complications, of whom 26 were patients with definite APS, were integrated in this study. Besides, aPL titres were compared to the S apporo standards. Results: Results of both systems agreed well with ELISA and mutually. Analysis of the discrepant results between Z enit and A custar finally led to one misclassification as APS. Conclusion: Diagnostic performances of both Z enit RA and HemosIL Acustar were comparable with odds ratios lower limits of CI of 5 for aβ 2 GPI IgG for Z enit and A custar and 6 and 5 for aCl IgG on Z enit and A custar, respectively. However, even with these new automated systems, titres differed largely between systems, especially for aβ 2 GPI IgG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1751-553x.2012.01448.x

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 56

Metadata

Authors
Van Hoecke, F., Persijn, L., Decavele, A. ‐., & Devreese, K.
Venue
International Journal of Laboratory Hematology
Publisher
Wiley
Published
2012-07-25
Volume
34
Issue
6
Pages
630-640
ISSN
  • 1751-5521 (ISSN-L)
  • 1751-553X
OpenAlex
W2035160119
Cited by
56
References
11
FWCI
2.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of two new, automated chemiluminescence assay panels for anticardiolipin and anti‐beta2‐glycoprotein I antibodies in the laboratory diagnosis of the antiphospholipid syndrome. https://app.cochat.ai/papers/10.1111/j.1751-553x.2012.01448.x
The paper
Van Hoecke, F., Persijn, L., Decavele, A. ‐., & Devreese, K. (2012). Performance of two new, automated chemiluminescence assay panels for anticardiolipin and anti‐beta2‐glycoprotein I antibodies in the laboratory diagnosis of the antiphospholipid syndrome. International Journal of Laboratory Hematology. https://doi.org/10.1111/j.1751-553x.2012.01448.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.