The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms
Open accessAbstract
Loop-mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. ( Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro-organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro-organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real-time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro-organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Accelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,045
Mori, Y., Nagamine, K., Tomita, N., & Notomi, T. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5921 · Cited by 1,711
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Loop-mediated isothermal amplification (LAMP): principle, features, and future prospects
Notomi, T., Mori, Y., Tomita, N., & Kanda, H. (2015) · Journal of Microbiology · doi:10.1007/s12275-015-4656-9 · Cited by 889
Strand displacement amplification—an isothermal,in vitro DNA amplification technique
Walker, G. T., Fraiser, M. S., Schram, J. L., Little, M. C., Nadeau, J. G., & Malinowski, D. P. (1992) · Nucleic Acids Research · doi:10.1093/nar/20.7.1691 · Cited by 850
Parida, M., Sannarangaiah, S., Dash, P. K., Rao, P. V. L., & Morita, K. (2008) · Reviews in Medical Virology · doi:10.1002/rmv.593 · Cited by 756
Tolerance of loop-mediated isothermal amplification to a culture medium and biological substances
Kaneko, H., Kawana, T., Fukushima, E., & Suzutani, T. (2007) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2006.08.008 · Cited by 707
Guatelli, J. C., Whitfield, K. M., Kwoh, D. Y., Barringer, K. J., Richman, D. D., & Gingeras, T. R. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.5.1874 · Cited by 540
Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications
Francois, P., Tangomo, M., Hibbs, J., Bonetti, E.-J., Boehme, C. C., Notomi, T., Perkins, M. D., & Schrenzel, J. (2011) · FEMS Immunology & Medical Microbiology · doi:10.1111/j.1574-695x.2011.00785.x · Cited by 501
Cited by
Esbin, M. N., Whitney, O. N., Chong, S., Maurer, A., Darzacq, X., & Tjian, R. (2020) · RNA · doi:10.1261/rna.076232.120 · Cited by 477
Zhu, X., Wang, X., Han, L., Chen, T., Wang, L., Li, H., Li, S., He, L., Fu, X., Chen, S., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112437 · Cited by 454
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community
Moehling, T. J., Choi, G., Dugan, L. C., Salit, M., & Meagher, R. J. (2021) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2021.1873769 · Cited by 286
Augustine, R., Hasan, A., Das, S., Ahmed, R., Mori, Y., Notomi, T., Kevadiya, B., & Thakor, A. (2020) · Biology · doi:10.3390/biology9080182 · Cited by 253
Nanozyme-catalysed CRISPR assay for preamplification-free detection of non-coding RNAs
Broto, M., Kaminski, M. M., Adrianus, C., Kim, N., Greensmith, R., Dissanayake-Perera, S., Schubert, A. J., Tan, X., Kim, H., Dighe, A. S., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01179-0 · Cited by 253
(2023) · doi:10.1016/j.xcrm.2023.101037 · Cited by 75
Diallo, K., Feteh, V. F., Ibe, L., Antonio, M., Caugant, D. A., du Plessis, M., Deghmane, A.-E., Feavers, I. M., Fernandez, K., Fox, L. M., et al. (2021) · EBioMedicine · doi:10.1016/j.ebiom.2021.103274 · Cited by 51
Andrés-Lasheras, S., Jelinski, M., Zaheer, R., & McAllister, T. A. (2022) · Antibiotics · doi:10.3390/antibiotics11040487 · Cited by 42
Metadata
- Authors
- Wong, Y.-P., Othman, S., Lau, Y.-L., Radu, S., & Chee, H.-Y.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-02-12
- Volume
- 124
- Issue
- 3
- Pages
- 626-643
- ISSN
- 1364-5072 (ISSN-L)
- OpenAlex
- W2770752141
- Cited by
- 712
- References
- 66
- FWCI
- 12.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.