Meta‐analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis
Abstract
Aims: This meta‐analysis aims to compare the diagnostic performance of acoustic radiation force impulse (ARFI) elastography and transient elastography (TE) in the assessment of liver fibrosis using liver biopsy (LB) as ‘gold‐standard’. Methods: PubMed, Medline, Lilacs, Scopus, Ovid, EMBASE, Cochrane and Medscape databases were searched for all studies published until 31 May 2012 that evaluated the liver stiffness by means of ARFI, TE and LB. Information abstracted from each study according to a fixed protocol included study design and methodological characteristics, patient characteristics, interventions, outcomes and missing outcome data. Results: Thirteen studies (11 full‐length articles and 2 abstracts) including 1163 patients with chronic hepatopathies were included in the analysis. Inability to obtain reliable measurements was more than thrice as high for TE as that of ARFI (6.6% vs. 2.1%, P < 0.001). For detection of significant fibrosis, (F ≥ 2) the summary sensitivity (Se) was 0.74 (95% CI: 0.66–0.80) and specificity (Sp) was 0.83 (95% CI: 0.75–0.89) for ARFI, while for TE the Se was 0.78 (95% CI: 0.72–0.83) and Sp was 0.84 (95% CI: 0.75–0.90). For the diagnosis of cirrhosis, the summary Se was 0.87 (95% CI: 0.79–0.92) and Sp was 0.87 (95% CI: 0.81–0.91) for ARFI elastography, and, respectively, 0.89 (95% CI: 0.80–0.94) and 0.87 (95% CI: 0.82–0.91) for TE. The diagnostic odds ratio of ARFI and TE did not differ significantly in the detection of significant fibrosis [mean difference in rDOR = 0.27 (95% CI: 0.69–0.14)] and cirrhosis [mean difference in rDOR = 0.12 (95% CI: 0.29–0.52)]. Conclusion: Acoustic radiation force impulse elastography seems to be a good method for assessing liver fibrosis, and shows higher rate of reliable measurements and similar predictive value to TE for significant fibrosis and cirrhosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Castéra, L., Vergniol, J., Foucher, J., Le Bail, B., Chanteloup, E., Haaser, M., Darriet, M., Couzigou, P., & de Lédinghen, V. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.018 · Cited by 2,487
Sampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection
Regev, A., Berho, M. E., Jeffers, L. J., Milikowski, C., Molina, E. G., Pyrsopoulos, N., Feng, Z.-Z., Reddy, K. R., & Schiff, E. R. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04396-4 · Cited by 2,093
Rockey, D. C., Caldwell, S. H., Goodman, Z. D., Nelson, R. C., & Smith, A. D. (2009) · Hepatology · doi:10.1002/hep.22742 · Cited by 1,997
Performance of Transient Elastography for the Staging of Liver Fibrosis: A Meta-Analysis
Friedrich–Rust, M., Ong, M., Martens, S., Sarrazin, C., Bojunga, J., Zeuzem, S., & Herrmann, E. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.01.034 · Cited by 1,490
Wong, V. W.-S., Vergniol, J., Wong, G. L.-H., Foucher, J., Chan, H. L.-Y., Le Bail, B., Choi, P. C.-L., Kowo, M., Chan, A. W.-H., Merrouche, W., et al. (2010) · Hepatology · doi:10.1002/hep.23312 · Cited by 1,322
Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations
Castéra, L., Foucher, J., Bernard, P.-H., Carvalho, F., Allaix, D., Merrouche, W., Couzigou, P., & de Lédinghen, V. (2010) · Hepatology · doi:10.1002/hep.23425 · Cited by 1,159
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Serum markers detect the presence of liver fibrosis: A cohort study
Rosenberg, W. M. C., Voelker, M., Thiel, R., Becka, M., Burt, A., Schuppan, D., Hubscher, S., Roskams, T., Pinzani, M., & Arthur, M. J. P. (2004) · Gastroenterology · doi:10.1053/j.gastro.2004.08.052 · Cited by 1,102
Assessment of Hepatic Fibrosis With Magnetic Resonance Elastography
Yin, M., Talwalkar, J. A., Glaser, K. J., Manduca, A., Grimm, R. C., Rossman, P. J., Fidler, J. L., & Ehman, R. L. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.06.012 · Cited by 948
Guha, I. N., Parkes, J., Roderick, P., Chattopadhyay, D., Cross, R., Harris, S., Kaye, P., Burt, A. D., Ryder, S. D., Aithal, G. P., et al. (2008) · Hepatology · doi:10.1002/hep.21984 · Cited by 745
Tsochatzis, E. A., Gurusamy, K. S., Ntaoula, S., Cholongitas, E., Davidson, B. R., & Burroughs, A. K. (2011) · Journal of Hepatology · doi:10.1016/j.jhep.2010.07.033 · Cited by 709
Friedrich-Rust, M., Wunder, K., Kriener, S., Sotoudeh, F., Richter, S., Bojunga, J., Herrmann, E., Poynard, T., Dietrich, C. F., Vermehren, J., et al. (2009) · Radiology · doi:10.1148/radiol.2523081928 · Cited by 620
Extrahepatic cholestasis increases liver stiffness (FibroScan) irrespective of fibrosis
Millonig, G., Reimann, F. M., Friedrich, S., Fonouni, H., Mehrabi, A., Büchler, M. W., Seitz, H. K., & Mueller, S. (2008) · Hepatology · doi:10.1002/hep.22577 · Cited by 599
Liver stiffness is directly influenced by central venous pressure
Millonig, G., Friedrich, S., Adolf, S., Fonouni, H., Golriz, M., Mehrabi, A., Stiefel, P., Pöschl, G., Büchler, M. W., Seitz, H. K., et al. (2010) · Journal of Hepatology · doi:10.1016/j.jhep.2009.11.018 · Cited by 536
Talwalkar, J. A., Kurtz, D. M., Schoenleber, S. J., West, C. P., & Montori, V. M. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.07.020 · Cited by 523
Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage
Sagir, A., Erhardt, A., Schmitt, M., & Häussinger, D. (2008) · Hepatology · doi:10.1002/hep.22056 · Cited by 513
Myers, R. P., Pomier–Layrargues, G., Kirsch, R., Pollett, A., Duarte–Rojo, A., Wong, D., Beaton, M., Levstik, M., Crotty, P., & Elkashab, M. (2012) · Hepatology · doi:10.1002/hep.24624 · Cited by 503
Friedrich‐Rust, M., Nierhoff, J., Lupsor, M., Sporea, I., Fierbinteanu‐Braticevici, C., Strobel, D., Takahashi, H., Yoneda, M., Suda, T., Zeuzem, S., et al. (2012) · Journal of Viral Hepatitis · doi:10.1111/j.1365-2893.2011.01537.x · Cited by 475
Self-citationBavu, É., Gennisson, J.-L., Couade, M., Bercoff, J., Mallet, V., Fink, M., Badel, A., Vallet-Pichard, A., Nalpas, B., Tanter, M., et al. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.016 · Cited by 415
Shear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity
Deffieux, T., Montaldo, G., Tanter, M., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925077 · Cited by 411
Nonalcoholic Fatty Liver Disease: US-based Acoustic Radiation Force Impulse Elastography
Yoneda, M., Suzuki, K., Kato, S., Fujita, K., Nozaki, Y., Hosono, K., Saito, S., & Nakajima, A. (2010) · Radiology · doi:10.1148/radiol.10091662 · Cited by 348
Palmeri, M. L., Wang, M. H., Rouze, N. C., Abdelmalek, M. F., Guy, C. D., Moser, B., Diehl, A. M., & Nightingale, K. R. (2011) · Journal of Hepatology · doi:10.1016/j.jhep.2010.12.019 · Cited by 344
Real-Time Elastography for Noninvasive Assessment of Liver Fibrosis in Chronic Viral Hepatitis
Friedrich-Rust, M., Ong, M.-F., Herrmann, E., Dries, V., Samaras, P., Zeuzem, S., & Sarrazin, C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0322 · Cited by 325
Sampling Variability on Percutaneous Liver Biopsy
Abdi, W. (1979) · Archives of Internal Medicine · doi:10.1001/archinte.139.6.667 · Cited by 274
Lupșor‐Platon, M., Badea, R. I., Ştefănescu, H., Sparchez, Z. A., Branda, H., Serban, A., & Maniu, A. (2009) · PubMed · Cited by 274
Poynard, T., Imbert‐Bismut, F., Ratziu, V., Chevret, S., Jardel, C., Moussalli, J., Messous, D., Degos, F., & for the GERMED cyt04 group (2002) · Journal of Viral Hepatitis · doi:10.1046/j.1365-2893.2002.00341.x · Cited by 219
A Meta-analysis of Transient Elastography for the Detection of Hepatic Fibrosis
Stebbing, J., Farouk, L., Panos, G., Anderson, M., Jiao, L. R., Mandalia, S., Bower, M., Gazzard, B., & Nelson, M. (2010) · Journal of Clinical Gastroenterology · doi:10.1097/mcg.0b013e3181b4af1f · Cited by 212
De Lédinghen, V., Vergniol, J., Foucher, J., El-Hajbi, F., Merrouche, W., & Rigalleau, V. (2010) · Liver International · doi:10.1111/j.1478-3231.2010.02258.x · Cited by 205
Rizzo, L., Calvaruso, V., Cacopardo, B., Alessi, N., Attanasio, M., Petta, S., Fatuzzo, F., Montineri, A., Mazzola, A., L'abbate, L., et al. (2011) · American Journal of Gastroenterology · doi:10.1038/ajg.2011.341 · Cited by 200
Friedrich-Rust, M., Romen, D., Vermehren, J., Kriener, S., Sadet, D., Herrmann, E., Zeuzem, S., & Bojunga, J. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.10.029 · Cited by 188
Crespo, G., Fernández-Varo, G., Mariño, Z., Casals, G., Miquel, R., Martínez, S. M., Gilabert, R., Forns, X., Jiménez, W., & Navasa, M. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2012.03.016 · Cited by 164
Sporea, I., Șirli, R., Deleanu, A. E., Popescu, A., Focşa, M., Danilă, M., & Tudora, A. (2010) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0029-1245360 · Cited by 143
Self-citationPerformance of unidimensional transient elastography in staging non-alcoholic steatohepatitis.
Lupșor‐Platon, M., Badea, R., Ştefănescu, H., Grigorescu, M. D., Serban, A., Radu, C., Crișan, D., Sparchez, Z. A., Iancu, S., & Maniu, A. (2010) · PubMed · Cited by 129
Lab, V. H. H., Reiberger, T., Ferlitsch, A., Payer, B. A., Pinter, M., Homoncik, M., & Peck‐Radosavljevic, M. (2011) · Journal of Gastroenterology · doi:10.1007/s00535-011-0517-4 · Cited by 127
Self-citationHavre, R. F., Elde, E., Gilja, O. H., Ødegaard, S., Eide, G. E., Matre, K., & Nesje, L. B. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.03.009 · Cited by 121
Colombo, S., Buonocore, M., Poggio, A. D., Jamoletti, C., Elia, S., Mattiello, M., Zabbialini, D., & Poggio, P. D. (2012) · Journal of Gastroenterology · doi:10.1007/s00535-011-0509-4 · Cited by 117
Ebinuma, H., Saito, H., Komuta, M., Ojiro, K., Wakabayashi, K., Usui∥, S., Chu, P., Umeda, R., Ishibashi∥, Y., Takayama, T., et al. (2011) · Journal of Gastroenterology · doi:10.1007/s00535-011-0437-3 · Cited by 116
Acoustic Radiation Force Impulse (ARFI)--a new modality for the evaluation of liver fibrosis.
Sporea, I., Șirli, R., Popescu, A., & Danilă, M. (2010) · PubMed · Cited by 110
Self-citationTatsumi, C., Kudo, M., Ueshima, K., Kitai, S., Takahashi, S., Inoue, T., Minami, Y., Chung, H., Maekawa, K., Fujimoto, K., et al. (2008) · Intervirology · doi:10.1159/000122602 · Cited by 109
Yoon, K. T., Lim, S. M., Park, J. Y., Kim, D. Y., Ahn, S. H., Han, K., Chon, C. Y., Cho, M., Lee, J. W., & Kim, S. U. (2012) · Digestive Diseases and Sciences · doi:10.1007/s10620-012-2044-4 · Cited by 100
Liver stiffness measurements in patients with HBV vs HCV chronic hepatitis: A comparative study
Sporea, I., Sirli, R., Deleanu, A., Tudora, A., Popescu, A., Curescu, M., & Bota, S. (2010) · World Journal of Gastroenterology · doi:10.3748/wjg.v16.i38.4832 · Cited by 86
Self-citationKIRCHEIS, G. (2012) · World Journal of Gastroenterology · doi:10.3748/wjg.v18.i10.1077 · Cited by 57
Liver Biopsy in Cirrhotic Patients
Sherman, K. E., Goodman, Z. D., Sullivan, S. T., Faris-Young, S., & for the GILF Study Group (2007) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2007.01110.x · Cited by 41
Karlas, T., Pfrepper, C., Rosendahl, J., Benckert, C., Wittekind, C., Jonas, S., Moessner, J., Tröltzsch, M., Tillmann, H. L., Berg, T., et al. (2011) · Zeitschrift für Gastroenterologie · doi:10.1055/s-0029-1245690 · Cited by 40
Is it better to use two elastographic methods for liver fibrosis assessment?
Sporea, I. (2011) · World Journal of Gastroenterology · doi:10.3748/wjg.v17.i33.3824 · Cited by 31
Self-citationRiggio, S., Mamone, F., Mandraffino, G., Maimone, S., Alibrandi, A., Manti, L., Saitta, C., Tripodi, P. F., Sardo, M. A., Squadrito, G., et al. (2010) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2010.02323.x · Cited by 16
Cited by
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
“001), especially in patients with ascites or obesity [90].”
BackgroundMethodDietrich, C., Bamber, J., Berzigotti, A., Bota, S., Cantisani, V., Castera, L., Cosgrove, D., Ferraioli, G., Friedrich-Rust, M., Gilja, O., et al. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0043-103952 · Cited by 1,011
Self-citationMack, C. L., Adams, D., Assis, D. N., Kerkar, N., Manns, M. P., Mayo, M. J., Vierling, J. M., Alsawas, M., Murad, M. H., & Czaja, A. J. (2020) · Hepatology · doi:10.1002/hep.31065 · Cited by 983
“(256,272,273) The accuracy of ARFI for cirrhosis exceeds 90% (sensitivity, 93%; specificity, 85%),(274) and results by meta-analysis of 13 studies have been comparable to VCTE in predicting fibrosis stage ≥2 and cirrhosis.(275) Splenic stiffness by ARFI has also correlated with the grade of esophageal varices, and ARF…”
BackgroundWFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 3: Liver
Ferraioli, G., Filice, C., Castera, L., Choi, B. I., Sporea, I., Wilson, S. R., Cosgrove, D., Dietrich, C. F., Amy, D., Bamber, J. C., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.007 · Cited by 879
Self-citationNonalcoholic fatty liver disease
Brunt, E. M., Wong, V. W.-S., Nobili, V., Day, C. P., Sookoian, S., Maher, J. J., Bugianesi, E., Sirlin, C. B., Neuschwander-Tetri, B. A., & Rinella, M. E. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.80 · Cited by 818
Metadata
- Authors
- Bota, S., Herkner, H., Sporea, I., Salzl, P., Sirli, R., Neghina, A. M., & Peck‐Radosavljevic, M.
- Venue
- Liver International
- Publisher
- Wiley
- Published
- 2013-07-16
- Volume
- 33
- Issue
- 8
- Pages
- 1138-1147
- ISSN
- 0106-9543 (ISSN-L)
- 1478-3223
- 1478-3231
- OpenAlex
- W2089622382
- Cited by
- 425
- References
- 49
- FWCI
- 30.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.