The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Reversible Nerve Conduction Block Using Kilohertz Frequency Alternating Current
Open accessAbstract
The features and clinical applications of balanced‐charge kilohertz frequency alternating currents (KHFAC) are reviewed. Preclinical studies of KHFAC block have demonstrated that it can produce an extremely rapid and reversible block of nerve conduction. Recent systematic analysis and experimentation utilizing KHFAC block have resulted in a significant increase in interest in KHFAC block, both scientifically and clinically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Rattay, F. (1990) · doi:10.1007/978-3-7091-3271-5 · Cited by 190
Comparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02368010 · Cited by 163
The EMPOWER Study Group, Sarr, M. G., Billington, C. J., Brancatisano, R., Brancatisano, A., Toouli, J., Kow, L., Nguyen, N. T., Blackstone, R., Maher, J. W., et al. (2012) · Obesity Surgery · doi:10.1007/s11695-012-0751-8 · Cited by 162
Foldes, E. L., Ackermann, D. M., Bhadra, N., Kilgore, K. L., & Bhadra, N. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.020 · Cited by 61
Self-citation
Cited by
Noninvasive Deep Brain Stimulation via Temporally Interfering Electric Fields
Grossman, N., Bono, D., Dedic, N., Kodandaramaiah, S. B., Rudenko, A., Suk, H.-J., Cassara, A. M., Neufeld, E., Kuster, N., Tsai, L.-H., et al. (2017) · Cell · doi:10.1016/j.cell.2017.05.024 · Cited by 986
Deer, T. R., Mekhail, N., Provenzano, D., Pope, J., Krames, E., Leong, M., Levy, R. M., Abejon, D., Buchser, E., Burton, A., et al. (2014) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12208 · Cited by 596
The vagus nerve in appetite regulation, mood, and intestinal inflammation
Browning, K. N., Verheijden, S., & Boeckxstaens, G. E. (2017) · Gastroenterology · doi:10.1053/j.gastro.2016.10.046 · Cited by 361
Role of the vagus nerve in the development and treatment of diet‐induced obesity
de Lartigue, G. (2016) · The Journal of Physiology · doi:10.1113/jp271538 · Cited by 238
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54
Effects of frequency-dependent membrane capacitance on neural excitability
Howell, B., Medina, L. E., & Grill, W. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056015 · Cited by 39
An ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces
Lancashire, H. T., Jiang, D., Demosthenous, A., & Donaldson, N. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891284 · Cited by 15
Metadata
- Authors
- Kilgore, K. L., & Bhadra, N.
- Venue
- Neuromodulation: Technology at the Neural Interface
- Publisher
- Elsevier BV
- Published
- 2014-04
- Volume
- 17
- Issue
- 3
- Pages
- 242-255
- ISSN
- 1094-7159 (ISSN-L)
- OpenAlex
- W1946085648
- Cited by
- 250
- References
- 6
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.