ASVCP Guidelines: Principles of Quality Assurance and Standards for Veterinary Clinical Pathology (version 3.0): Developed by the American Society for Veterinary Clinical Pathology's (ASVCP) Quality Assurance and Laboratory Standards (QALS) Committee
The DOI matches its Crossref record; 135 of the 135 references it cites were found in a registry or an index.
Abstract
In the United States, the Centers for Medicare and Medicaid Services (CMS) regulates all human clinical laboratory testing as mandated by federal legislation entitled the Clinical Laboratory Improvement Amendments (CLIA). Other countries have similar regulations. In contrast, veterinary medicine is not uniformly governmentally regulated, and to our (contributors) knowledge, instruments marketed for veterinary testing are not required to have independent analysis or approval prior to sale. Although there is not a current global consensus for human medicine on standards of laboratory performance, there are various supporting consensus and/or accrediting organizations that provide standards and guidelines. Examples include, but are not limited to: Clinical Laboratory Standards Institute (CLSI, formerly NCCLS), International Organization for Standardization (ISO), International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), International Laboratory Accreditation Cooperation (ILAC), International Council for Standardization of Haematology (ICSH), European Federation of Clinical Chemistry and Laboratory Medicine (EFLM), American Association for Laboratory Accreditation (A2LA), American Association for Clinical Chemistry (AACC), College of American Pathologists (CAP), World Organization for Animal Health (OIE), and Joint Committee for Guides in Metrology (JCGM). Failure of human laboratories to correct issues of non-compliance to federal legislation (CLIA or non-U.S. equivalent) results in lack of accreditation and termination of laboratory function. Limited government regulation exists for some aspects of clinical veterinary laboratory medicine in the U.S., mainly in place for reportable diseases. Laboratory accreditation is offered by the American Association of Veterinary Laboratory Diagnosticians (AAVLD) and is optional (per their website, this accreditation is "designed for state and national institutions or organizations such as colleges, departments or laboratories, and government agencies"a). ISO certification exists for veterinary laboratories but is also voluntary and is not prescriptive (ie, the certification is a commitment statement from the laboratory, not a top-down assurance of the standards which are provided in the guideline ISO:15189). The American Animal Hospital Association (AAHA) and the Royal College of Veterinary Surgeons (in the United Kingdom) have a laboratory quality section as a component of their overall veterinary hospital accreditation programs. The imperative for quality control and continuous quality improvement in veterinary clinical diagnostic laboratories and research organizations is self-evident. Inaccurate data that inform diagnostic/treatment modalities, scholarly research, and pharmaceutical development result in poor outcomes for individual patients and larger target populations, with corresponding ethical, financial, professional, and legal ramifications. Lack of understanding of causes of the statistical uncertainties that are inherent in all biologic measurements can/does lead to misdiagnosis. This guideline is aimed at advancing the ethos of continuous quality improvement in the veterinary laboratory setting, by raising awareness of potential sources of laboratory error, by providing recommendations for evaluation of current practices/identification of potential areas of improvement, and by providing actionable goals and tools for launching and refining systems of total quality management. The ultimate objective is maximizing the quality of laboratory output and thus value to clients/users and patients. The sections of this guideline are not intended to be all-inclusive. Rather, they provide a minimum standard for quality assurance in veterinary laboratories. They may augment, but should not substitute for, any applicable licensing/accreditation or good laboratory practice (GLP) standards, which are typically more specific per federal/state governing body requirements. This guideline does not distinguish quality assurance information and recommendations in relation to larger reference laboratories/academic institutions vs. the private practice setting. For more information on in-clinic laboratory quality assurance, please see the ASVCP Guideline: Quality assurance for point-of-care testing in veterinary medicine. This guideline is a revision of the previous (finalized 2009) document of the same name, American Society for Veterinary Clinical Pathology's Principles of Quality Assurance and Standards for Veterinary Clinical Pathology, developed by the Quality Assurance and Laboratory Standards (QALS) committee (and colloquially known as the "general guideline"), archived on the ASVCP website (www.asvcp.org/page/QALS_Guidelines), on a newly established Wiley freeware page (https://onlinelibrary.wiley.com/page/journal/1939165x/homepage/Qals) as published in Veterinary Clinical Pathology in three sectional special reports.1-3 This guideline's intended audi
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Schalm's Veterinary Hematology
(2022) · Wiley eBooks · doi:10.1002/9781119500537 · Cited by 2,899
Ireson, W. G., & Juran, J. M. (1952) · Journal of the American Statistical Association · doi:10.2307/2280757 · Cited by 2,849
Schalm's veterinary hematology
Grant, D. (1987) · Food and Chemical Toxicology · doi:10.1016/0278-6915(87)90029-9 · Cited by 2,321
Tietz Textbook of Clinical Chemistry and Molecular Diagnostics
Burtis, E. B. C. A., Ashwood, E. R., & Bruns, D. E. (2011) · Medical Entomology and Zoology · Cited by 2,190
Dukes' Physiology of Domestic Animals
Heath, T. (1994) · Australian Veterinary Journal · doi:10.1111/j.1751-0813.1994.tb03389.x · Cited by 1,355
Friedrichs, K. R., Harr, K. E., Freeman, K. P., Szladovits, B., Walton, R. M., Barnhart, K. F., & Blanco‐Chavez, J. (2012) · Veterinary Clinical Pathology · doi:10.1111/vcp.12006 · Cited by 1,293
Self-citationA New Blood Diluent for Counting the Erythrocytes and Leucocytes of the Chicken
Natt, M. P., & Herrick, C. A. (1952) · Poultry Science · doi:10.3382/ps.0310735 · Cited by 1,055
Veterinary Hematology and Clinical Chemistry
Sharkey, L. C. (2004) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2004.tb00383.x · Cited by 948
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Biological Variation: From Principles to Practice
Fraser, C. G. (2001) · Cited by 653
The detection and prevention of errors in laboratory medicine
Plebani, M. (2010) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009222 · Cited by 479
The acute phase response and innate immunity of fish
Bayne, C. J., & Gerwick, L. (2001) · Developmental & Comparative Immunology · doi:10.1016/s0145-305x(01)00033-7 · Cited by 469
(2002) · JAMA · doi:10.1001/jama.288.4.516-jbk0724-4-1 · Cited by 437
European Urinalysis Guidelines
Kouri, T., Fogazzi, G., Gant, V., Hallander, H., Hofmann, W., & Guder, W. G. (2000) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2000.12056993 · Cited by 384
Weese, J. S., Blondeau, J. M., Boothe, D. M., Breitschwerdt, E. B., Guardabassi, L., Hillier, A., Lloyd, D. H., Papich, M. G., Rankin, S. C., Turnidge, J. D., et al. (2011) · Veterinary Medicine International · doi:10.4061/2011/263768 · Cited by 371
Park, J. Y., & Kricka, L. J. (2013) · The Immunoassay Handbook · doi:10.1016/b978-0-08-097037-0.00027-0 · Cited by 365
Suggested Guidelines for Immunohistochemical Techniques in Veterinary Diagnostic Laboratories
Ramos-Vara, J. A., Kiupel, M., Baszler, T., Bliven, L., Brodersen, B., Chelack, B., West, K., Czub, S., Del Piero, F., Dial, S., et al. (2008) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/104063870802000401 · Cited by 350
Method comparison in the clinical laboratory
Jensen, A. L., & Kjelgaard‐Hansen, M. (2006) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2006.tb00131.x · Cited by 341
Stability study of 81 analytes in human whole blood, in serum and in plasma
Oddoze, C., Lombard, E., & Portugal, H. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.01.012 · Cited by 303
Managing the Pre- and Post-analytical Phases of the Total Testing Process
Hawkins, R. (2012) · Annals of Laboratory Medicine · doi:10.3343/alm.2012.32.1.5 · Cited by 244
Criteria for judging precision and accuracy in method development and evaluation
Westgard, J. O., Carey, R. N., & Wold, S. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.7.825 · Cited by 236
ASVCP guidelines: allowable total error guidelines for biochemistry
Harr, K. E., Flatland, B., Nabity, M., & Freeman, K. P. (2013) · Veterinary Clinical Pathology · doi:10.1111/vcp.12101 · Cited by 227
Self-citationEffect of anticoagulants and storage temperatures on stability of plasma and serum hormones
Evans, M. J., Livesey, J. H., Ellis, M. J., & Yandle, T. G. (2001) · Clinical Biochemistry · doi:10.1016/s0009-9120(01)00196-5 · Cited by 223
The Brain-to-Brain Loop Concept for Laboratory Testing 40 Years After Its Introduction
Plebani, M., Laposata, M., & Lundberg, G. D. (2011) · American Journal of Clinical Pathology · doi:10.1309/ajcpr28hwhssdnon · Cited by 212
Extraction and Analysis of Cortisol from Human and Monkey Hair
Meyer, J., Novak, M., Hamel, A., & Rosenberg, K. (2014) · Journal of Visualized Experiments · doi:10.3791/50882 · Cited by 198
Quality Standards for Sample Collection in Coagulation Testing
Lippi, G., Salvagno, G., Montagnana, M., Lima-Oliveira, G., Guidi, G., & Favaloro, E. (2012) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0032-1315961 · Cited by 196
Ricós, C., Cava, F., García‐Lario, J. V., Hernández, A., Iglesias, N., Jiménez, C. V., Minchinela, J., Perich, C., Simón, M., Domenech, M. V., et al. (2004) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510410004885 · Cited by 168
Serum proteins and their diagnostic utility in veterinary medicine: a review
Tothova, C., Nagy, O., & Kovac, G. (2016) · Veterinární medicína · doi:10.17221/19/2016-vetmed · Cited by 163
Laposata, M., & Dighe, A. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.173 · Cited by 162
The IFCC Working Group on laboratory errors and patient safety
Sciacovelli, L., & Plebani, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.025 · Cited by 161
Harmonization of quality indicators in laboratory medicine. A preliminary consensus
Plebani, M., Astion, M. L., Barth, J. H., Chen, W., de Oliveira Galoro, C. A., Escuer, M. I., Ivanov, A., Miller, W. G., Petinos, P., Sciacovelli, L., et al. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0142 · Cited by 160
Early diagnosis of renal disease and renal failure
Lees, G. E. (2004) · Veterinary Clinics of North America Small Animal Practice · doi:10.1016/j.cvsm.2004.03.004 · Cited by 147
Performance criteria and quality indicators for the post-analytical phase
Sciacovelli, L., Aita, A., Padoan, A., Pelloso, M., Antonelli, G., Piva, E., Chiozza, M. L., & Plebani, M. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0897 · Cited by 142
Stöckl, D., Dewitte, K., & Thienpont, L. M. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.11.2340 · Cited by 138
Hens, K. A., Berth, M., Armbruster, D., & Westgard, S. A. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-1090 · Cited by 128
Adcock, D. M., Kressin, D. C., & Marlar, R. A. (1998) · American Journal of Clinical Pathology · doi:10.1093/ajcp/109.5.595 · Cited by 120
A model for a comprehensive measurement system in clinical chemistry.
Tietz, N. W. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.6.833 · Cited by 119
Effects of storage temperature and time on clinical biochemical parameters from rat serum.
Cray, C., Rodriguez, M., Zaias, J., & Altman, N. H. (2009) · PubMed · Cited by 116
Commutability Limitations Influence Quality Control Results with Different Reagent Lots
Miller, W. G., Erek, A., Cunningham, T. D., Oladipo, O. O., Scott, M. G., & Johnson, R. E. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.148106 · Cited by 115
The use of error and uncertainty methods in the medical laboratory
Oosterhuis, W. P., Bayat, H., Armbruster, D., Coşkun, A., Freeman, K. P., Kallner, A., Koch, D. D., MacKenzie, F., Migliarino, G. A., Orth, M., et al. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0341 · Cited by 109
Self-citationASVCP guidelines: quality assurance for point‐of‐care testing in veterinary medicine
Flatland, B., Freeman, K. P., Vap, L. M., & Harr, K. E. (2013) · Veterinary Clinical Pathology · doi:10.1111/vcp.12099 · Cited by 109
Self-citationPetersen, P. H., Stöckl, D., Blaabjerg, O., Pedersen, B., Birkemose, E., Thienpont, L. M., Lassen, J. F., & Kjeldsen, J. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.11.2039 · Cited by 108
Algeciras‐Schimnich, A., Bruns, D. E., Boyd, J. C., Bryant, S. C., Fortune, K. A. L., & Grebe, S. K. G. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.205070 · Cited by 107
ASVCP guidelines: Allowable total error hematology
Nabity, M. B., Harr, K. E., Camus, M. S., Flatland, B., & Vap, L. M. (2018) · Veterinary Clinical Pathology · doi:10.1111/vcp.12583 · Cited by 107
Self-citationImportance of blood groups and blood group antibodies in companion animals
Hohenhaus, A. E. (2004) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2003.12.003 · Cited by 106
ASVCP quality assurance guidelines: control of general analytical factors in veterinary laboratories
Flatland, B., Freeman, K. P., Friedrichs, K. R., Vap, L. M., Getzy, K. M., Evans, E. W., & Harr, K. E. (2010) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2010.00251.x · Cited by 106
Self-citationHormone stability in human whole blood
Ellis, M. J., Livesey, J. H., & Evans, M. J. (2003) · Clinical Biochemistry · doi:10.1016/s0009-9120(02)00440-x · Cited by 105
Towards a new paradigm in laboratory medicine: the five rights
Plebani, M. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0848 · Cited by 104
The effect of time and temperature variables on routine coagulation tests
Adcock, D. M., Kressin, D. C., & Marlar, R. A. (1998) · Blood Coagulation & Fibrinolysis · doi:10.1097/00001721-199809000-00002 · Cited by 103
Serum protein electrophoresis by CZE 2000 clinical capillary electrophoresis system
Bossuyt, X., Schiettekatte, G., Bogaerts, A., & Blanckaert, N. J. C. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.4.749 · Cited by 102
Challenges of measuring monoclonal proteins in serum
Keren, D. F., & Schroeder, L. F. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0862 · Cited by 99
Recommendations for standardized reporting of protein electrophoresis in Australia and New Zealand
Tate, J. R., Caldwell, G., Daly, J. J., Gillis, D., Jenkins, M. A., Jovanovich, S., Martin, H., Steele, R. H., Wienholt, L. A., & Mollee, P. N. (2012) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2011.011158 · Cited by 92
Clement, B., Gausman, J. N., & Marlar, R. A. (2016) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0036-1581128 · Cited by 89
Shojania, A. M., Tetreault, J., & Turnbull, G. J. (1988) · American Journal of Clinical Pathology · doi:10.1093/ajcp/89.1.19 · Cited by 89
Salesov, E., Boretti, F. S., Sieber‐Ruckstuhl, N. S., Rentsch, K. M., Riond, B., Hofmann‐Lehmann, R., Kircher, P. R., Grouzmann, E., & Reusch, C. E. (2015) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12569 · Cited by 89
Quality Indicators for the Total Testing Process
Plebani, M., Sciacovelli, L., & Aita, A. (2016) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2016.09.015 · Cited by 88
Effect of Blood Collection Tubes on Total Triiodothyronine and Other Laboratory Assays
Bowen, R. A. R., Chan, Y., Cohen, J., Rehak, N. N., Hortin, G. L., Csákó, G., & Remaley, A. T. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.043349 · Cited by 84
Planning Risk-Based SQC Schedules for Bracketed Operation of Continuous Production Analyzers
Westgard, J. O., Bayat, H., & Westgard, S. A. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.278291 · Cited by 81
Basal Serum Cortisol Concentration as a Screening Test for Hypoadrenocorticism in Dogs
Bovens, C. P., Tennant, K., Reeve, J. L., et al. (2014) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12415 · Cited by 76
Parvin, C. A. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.113639 · Cited by 75
Holowaychuk, M. K., Leader, J. L., & Monteith, G. J. (2014) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.244.4.431 · Cited by 75
Marlar, R. A., Potts, R. M., & Marlar, A. A. (2006) · American Journal of Clinical Pathology · doi:10.1309/rrqkt2jeyv33d19d · Cited by 74
The preanalytic phase in veterinary clinical pathology
Braun, J.-P. D., Bourgès-Abella, N. H., Geffré, A., Concordet, D., & Trumel, C. (2014) · Veterinary Clinical Pathology · doi:10.1111/vcp.12206 · Cited by 74
Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control
Westgard, J. O., & Westgard, S. A. (2016) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2016.09.008 · Cited by 68
Appropriateness in programs for continuous quality improvement in clinical laboratories
Plebani, M. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00177-3 · Cited by 68
Reneke, J., Etzell, J. E., Leslie, S. D., Ng, V. L., & Gottfried, E. L. (1998) · American Journal of Clinical Pathology · doi:10.1093/ajcp/109.6.754 · Cited by 67
Influence of temperature and time before centrifugation of specimens for routine coagulation testing
Salvagno, G. L., Lippi, G., Montagnana, M., Franchini, M., POLI, G., & Guidi, G. C. (2008) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2008.01058.x · Cited by 67
Lippi, G., Cervellin, G., & Mattiuzzi, C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.022 · Cited by 66
Vap, L. M., Harr, K. E., Arnold, J. E., Freeman, K. P., Getzy, K. M., Lester, S., & Friedrichs, K. R. (2012) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2012.00413.x · Cited by 66
Self-citationDetection and identification of monoclonal gammopathies by capillary electrophoresis
Henskens, Y., Winter, J., Pekelharing, J. M., & Ponjee, G. A. E. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.6.1184 · Cited by 66
AVIAN LEUCOCYTE COUNTING USING THE HEMOCYTOMETER
Dein, F. J., Wilson, A. C., Fischer, D. C., et al. (1994) · Journal of Zoo and Wildlife Medicine · Cited by 64
[Stability of steroids in plasma over a 10-year period].
Kley, H.-K., Schlaghecke, R., & Krüskemper, H. L. (1985) · PubMed · Cited by 63
Lyon, S. D., Sanderson, M. W., Vaden, S. L., Lappin, M. R., Jensen, W. A., & Grauer, G. F. (2010) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.236.8.874 · Cited by 63
Booth, R. A., McCudden, C. R., Balion, C. M., Blasutig, I. M., Bouhtiauy, I., Rodríguez-Capote, K., Catomeris, P., Chan, P. C., Chen, Y., Collier, C. P., et al. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.10.013 · Cited by 57
Transference and Validation of Reference Intervals
Tate, J. R., Yen, T., & Jones, G. R. D. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.243055 · Cited by 55
Flatland, B., Friedrichs, K. R., & Klenner, S. (2014) · Veterinary Clinical Pathology · doi:10.1111/vcp.12199 · Cited by 53
THE PRE-ANALYTICAL CHALLENGES OF ROUTINE URINALYSIS
Coppens, A., Speeckaert, M. M., & Delanghe, J. (2010) · Acta Clinica Belgica · doi:10.1179/acb.2010.038 · Cited by 51
Murray, D. J., Pennell, B. J., & Olson, J. D. (1999) · Transfusion · doi:10.1046/j.1537-2995.1999.39199116895.x · Cited by 49
Schifman, R. B., Talbert, M. L., & Souers, R. J. (2017) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2016-0161-cp · Cited by 48
Freeman, K. P., Baral, R. M., Dhand, N. K., Nielsen, S. S., & Jensen, A. L. (2017) · Veterinary Clinical Pathology · doi:10.1111/vcp.12475 · Cited by 48
Self-citationEffect of repeated freeze‐thaw cycles on routine plasma biochemical constituents in canine plasma
Reynolds, B., Taillade, B., Médaille, C., Palenché, F., Trumel, C., & Lefebvre, H. P. (2006) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2006.tb00144.x · Cited by 47
Quality Assurance in Clinical Chemistry: A Touch of Statistics and A Lot of Common Sense
Theodorsson, E. (2016) · Journal of Medical Biochemistry · doi:10.1515/jomb-2016-0012 · Cited by 46
Serum Albumin: Differences in Assay Specificity
Brackeen, G. L., Dover, J. S., & Long, C. L. (1989) · Nutrition in Clinical Practice · doi:10.1177/0115426589004006203 · Cited by 46
Peterson, P., & Gottfried, E. L. (1982) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1657138 · Cited by 45
Williams, T. P. E., Shaw, S., Porter, A., & Berkwitt, L. (2016) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/vec.12527 · Cited by 44
Automated and visual analysis of commercial urinary dipsticks in dogs, cats and cattle
Defontis, M., Bauer, N. B., Failing, K., & Moritz, A. (2013) · Research in Veterinary Science · doi:10.1016/j.rvsc.2013.01.002 · Cited by 44
Toulon, P. A., Eloit, Y., Smahi, M., Sigaud, C., Jambou, D., Fischer, F., & Appert‐Flory, A. (2016) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12499 · Cited by 43
Cytologic diagnosis: expression of probability by clinical pathologists
Christopher, M. M., & Hotz, C. S. (2004) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2004.tb00354.x · Cited by 42
Stability of selected serum hormones and lipids after long-term storage in the Janus Serum Bank
Gislefoss, R. E., Grimsrud, T. K., & Mørkrid, L. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.12.006 · Cited by 41
Performance criteria of the post-analytical phase
Sikaris, K. A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0016 · Cited by 37
Phalen, L. J., Köllner, B., Leclair, L. A., Hogan, N., & van den Heuvel, M. R. (2013) · Aquatic Toxicology · doi:10.1016/j.aquatox.2013.12.017 · Cited by 36
Adding Outcome as the 10th Step in the Brain-to-Brain Laboratory Test Loop
Lundberg, G. D. (2014) · American Journal of Clinical Pathology · doi:10.1309/ajcp5ksxwti2dmcc · Cited by 35
Smets, E. M. L., Dijkstra-Lagemaat, J. E., & Blankenstein, M. A. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.076 · Cited by 35
Maeckelbergh, V. A., & Acierno, M. J. (2008) · American Journal of Veterinary Research · doi:10.2460/ajvr.69.7.868 · Cited by 34
Selecting multi-rule quality control procedures based on patient risk
Bayat, H. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-1077 · Cited by 34
Arai, S., Griffiths, L. G., Mama, K. R., Hackett, T. B., Monnet, E. L., Boon, J. A., Carter, L., & Orton, E. C. (2011) · Journal of Veterinary Cardiology · doi:10.1016/j.jvc.2010.12.002 · Cited by 33
Rossi, R., Ippolito, L., Zobbi, V., et al. (2013) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1356572 · Cited by 31
An error management system in a veterinary clinical laboratory
Hooijberg, E. H., Leidinger, E. F., & Freeman, K. P. (2012) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638712441782 · Cited by 31
Self-citationAge-related changes in the concentrations of serum proteins in calves
Nagy, O., Tóthová, C., & Kovác, G. (2014) · Journal of Applied Animal Research · doi:10.1080/09712119.2013.875918 · Cited by 31
DVM, D. C. B., & VMD, S. P. (1998) · Veterinary Surgery · doi:10.1111/j.1532-950x.1998.tb00538.x · Cited by 30
Morales, F., Couto, C. G., & Iazbik, M. C. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb02992.x · Cited by 30
THE EVALUATION OF DIAGNOSTIC TESTS: Principles, Problems, and New Developments
Sox, H. C. (1996) · Annual Review of Medicine · doi:10.1146/annurev.med.47.1.463 · Cited by 30
Bowen, R. A. R., Sattayapiwat, A., Gounden, V., & Remaley, A. T. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.11.003 · Cited by 29
No influence of a butterfly device on routine coagulation assays and D‐dimer measurement
LIPPI, G., SALVAGNO, G. L., & GUIDI, G. C. (2005) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2005.01163.x · Cited by 28
Burgess, S. C., & Davison, T. F. (1999) · Journal of Immunological Methods · doi:10.1016/s0022-1759(99)00083-6 · Cited by 28
Mussap, M., Pietrogrande, F., Ponchia, S., Stefani, P. M., Sartori, R., & Plebani, M. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.112 · Cited by 27
Comparing Different Lots of Activated Partial Thromboplastin Time Reagent: Analysis of Two Methods
Rosborough, T. K. (1998) · American Journal of Clinical Pathology · doi:10.1093/ajcp/110.2.173 · Cited by 27
Analytical quality goals—a review
Flatland, B., Camus, M. S., & Baral, R. M. (2018) · Veterinary Clinical Pathology · doi:10.1111/vcp.12649 · Cited by 26
Self-citationUse of Compounded Adrenocorticotropic Hormone (ACTH) for Adrenal Function Testing in Dogs
Kemppainen, R. J., Behrend, E. N., & Busch, K. A. (2005) · Journal of the American Animal Hospital Association · doi:10.5326/0410368 · Cited by 25
Monoclonal gammopathy without hyperglobulinemia in 2 dogs with IgA secretory neoplasms
Seelig, D. M., Perry, J. A., Avery, A. C., & Avery, P. R. (2010) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2010.00262.x · Cited by 25
Comparison between the urine dipstick and the pH‐meter to assess urine pH in sheep and dogs
Athanasiou, L. V., Katsoulos, P. D., Katsogiannou, E. G., Polizopoulou, Z. S., Diamantaki, M., Kamatsos, C., & Christodoulopoulos, G. (2018) · Veterinary Clinical Pathology · doi:10.1111/vcp.12581 · Cited by 24
Bateman, S. W., Mathews, K. A., Abrams‐Ogg, A. C. G., Lumsden, J. H., & Johnstone, I. B. (1999) · PubMed Central · Cited by 24
Effect (or Lack of It) of Severe Anemia on PT and APTT Results
Siegel, J. E., Swami, V. K., Glenn, P., & Peterson, P. (1998) · American Journal of Clinical Pathology · doi:10.1093/ajcp/110.1.106 · Cited by 23
Evaluation of Hair Cortisol in the Diagnosis of Hypercortisolism in Dogs
Corradini, S., Accorsi, P. A., Boari, A., Beghelli, V., Mattioli, M., Famigli-Bergamini, P., & Fracassi, F. (2013) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12135 · Cited by 22
Inaccuracy of a “Spiked Curve” for Monitoring Unfractionated Heparin Therapy
Gausman, J. N., & Marlar, R. A. (2011) · American Journal of Clinical Pathology · doi:10.1309/ajcp60zgxcjkrmjo · Cited by 22
The estimation of platelet count from a blood smear on the basis of the red cell: platelet ratio.
Brahimi, M., Osmani, S., Arabi, A., Entasoltane, B., Taghezout, Z., Elkahili, B. S., & Bekadja, M. A. (2009) · PubMed · Cited by 20
Théron, M., Piane, L., Lucarelli, L., Henrion, R., Layssol‐Lamour, C., Palanché, F., Concordet, D., Braun, J.-P. D., Trumel, C., & Lavoué, R. (2017) · American Journal of Veterinary Research · doi:10.2460/ajvr.78.8.990 · Cited by 20
Casella, S., Giannetto, C., Fazio, F., et al. (2009) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/104063870902100512 · Cited by 19
Dimeski, G., Solano, C., Petroff, M. K., & Hynd, M. R. (2011) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2010.010230 · Cited by 19
Submitting canine blood for prothrombin time and partial thromboplastin time determinations.
Smalko, D., Johnstone, I. B., & Crane, S. (1985) · PubMed · Cited by 18
Full method validation in clinical chemistry
Theodorsson, E., & Magnusson, B. (2017) · Accreditation and Quality Assurance · doi:10.1007/s00769-017-1275-7 · Cited by 18
Piccione, G., Casella, S., Giannetto, C., et al. (2010) · Journal of Veterinary Science · doi:10.4142/jvs.2010.11.2.121 · Cited by 17
Recent initiatives in harmonization of hemostasis practice
Favaloro, E. J., Gosselin, R. C., Olson, J. D., Jennings, I., & Lippi, G. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0082 · Cited by 17
Daves, M., Giacomuzzi, K., Tagnin, E., Jani, E., Funk, D. M. A., Favaloro, E. J., & Lippi, G. (2014) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000026 · Cited by 17
Obtaining Coagulation Blood Samples From Central Venous Access Devices: A Review of the Literature
Dalton, K. A., Aucoin, J. W., & Meyer, B. M. (2015) · Clinical journal of oncology nursing · doi:10.1188/15.cjon.19-04ap · Cited by 17
Evaluation of automated assays for immunoglobulin G, M, and A measurements in dog and cat serum
Tvarijonaviciute, A., Martı́nez-Subiela, S., Caldín, M., Tecles, F., & Cerón, J. M. C. (2013) · Veterinary Clinical Pathology · doi:10.1111/vcp.12069 · Cited by 15
Christopher, M. M., Hotz, C. S., Shelly, S. M., & Pion, P. D. (2010) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2010.0492.x · Cited by 15
The Effect of Storage on the Protein Electrophoretic Pattern in Bovine Serum
Tóthová, C., Nagy, O., Seidel, H., & Kováč, G. (2010) · DOAJ (DOAJ: Directory of Open Access Journals) · doi:10.22067/veterinary.v2i2.8367 · Cited by 14
Baral, R. M., Dhand, N. K., & Freeman, K. P. (2016) · Veterinary Clinical Pathology · doi:10.1111/vcp.12357 · Cited by 13
Self-citationRepeat patient testing shows promise as a quality control method for veterinary hematology testing
Flatland, B., & Freeman, K. P. (2018) · Veterinary Clinical Pathology · doi:10.1111/vcp.12593 · Cited by 12
Self-citationMaunder, C. L., Costa, M., Cue, S. M., et al. (2012) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2012.01255.x · Cited by 9
Mackenzie, C., McGowan, C. M., Pinchbeck, G. L., & Carslake, H. B. (2017) · Equine Veterinary Journal · doi:10.1111/evj.12764 · Cited by 8
Biochemical assessment of canine body cavity effusions using three bench‐top analysers
Hetzel, N., Papasouliotis, K., Dodkin, S. J., & Murphy, K. F. (2012) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2012.01240.x · Cited by 7
The effects of transport by car on coagulation tests
Ergin, M., Erdoğan, S., Aktürk, O., & Erel, O. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0824 · Cited by 6
Metadata
- Authors
- Arnold, J. E., Camus, M. S., Freeman, K. P., Giori, L., Hooijberg, E. H., Jeffery, U., Korchia, J., Meindel, M. J., Moore, A. R., Sisson, S. C., Vap, L. M., & Cook, J. R.
- Venue
- Veterinary Clinical Pathology
- Publisher
- Wiley
- Published
- 2019-12
- Volume
- 48
- Issue
- 4
- Pages
- 542-618
- ISSN
- 0275-6382 (ISSN-L)
- 1939-165X
- OpenAlex
- W2996837786
- Cited by
- 158
- References
- 135
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.