Accurate and representative decoding of the neural drive to muscles in humans with multi‐channel intramuscular thin‐film electrodes
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Key points: Intramuscular electrodes developed over the past 80 years can record the concurrent activity of only a few motor units active during a muscle contraction. We designed, produced and tested a novel multi‐channel intramuscular wire electrode that allows in vivo concurrent recordings of a substantially greater number of motor units than with conventional methods. The electrode has been extensively tested in deep and superficial human muscles. The performed tests indicate the applicability of the proposed technology in a variety of conditions. The electrode represents an important novel technology that opens new avenues in the study of the neural control of muscles in humans. We describe the design, fabrication and testing of a novel multi‐channel thin‐film electrode for detection of the output of motoneurones in vivo and in humans, through muscle signals. The structure includes a linear array of 16 detection sites that can sample intramuscular electromyographic activity from the entire muscle cross‐section. The structure was tested in two superficial muscles (the abductor digiti minimi (ADM) and the tibialis anterior (TA)) and a deep muscle (the genioglossus (GG)) during contractions at various forces. Moreover, surface electromyogram (EMG) signals were concurrently detected from the TA muscle with a grid of 64 electrodes. Surface and intramuscular signals were decomposed into the constituent motor unit (MU) action potential trains. With the intramuscular electrode, up to 31 MUs were identified from the ADM muscle during an isometric contraction at 15% of the maximal force (MVC) and 50 MUs were identified for a 30% MVC contraction of TA. The new electrode detects different sources from a surface EMG system, as only one MU spike train was found to be common in the decomposition of the intramuscular and surface signals acquired from the TA. The system also allowed access to the GG muscle, which cannot be analysed with surface EMG, with successful identification of MU activity. With respect to classic detection systems, the presented thin‐film structure enables recording from large populations of active MUs of deep and superficial muscles and thus can provide a faithful representation of the neural drive sent to a muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Behaviour of human motor units in different muscles during linearly varying contractions
de Luca, C. J., LeFever, R. S., McCue, M. P., & Xenakis, A. P. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014293 · Cited by 719
Holobar, A., Minetto, M. A., & Farina, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016008 · Cited by 400 · cited 1×
“The MUs extracted from the surface EMG were considered to be accurately identified if the CoV of the ISI was <30%, according to the criterion proposed in Holobar et al. (2014).”
MethodSelf-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Self-citationDecoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383 · cited 1×
“Surface EMG decomposition, however, only allows identification of superficial MUs (Farina et al. 2010).”
BackgroundSelf-citationMicromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · cited 1×
“Polyimide thin-film technology was used, which allows the building of multiple small (and therefore selective) detection sites with reproducible site geometry, on a thin (10–20 μm) and flexible substrate (Stieglitz et al. 2000).”
MethodMotor unit firing rates and contractile properties in tibialis anterior of young and old men
Connelly, D. M., Rice, C. L., Roos, M. R., & Vandervoort, A. A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.2.843 · Cited by 340 · cited 1×
“For the TA muscle, the firing rate increased with the force intensity (e.g. Connelly et al. 1999) and the ISI CoV was higher at 10 than 20% MVC because some MUs detected at the lowest contraction level were close to the recruitment threshold and had a more irregular firing pattern at 10% MVC.”
MethodEstimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318 · cited 4×
“…for electrodes outside the motor unit territory. signals were decomposed with the convolution kernel compensation (CKC) method, which was introduced by Holobar & Zazula (2007) and has been previously validated in muscles with different architectures (Holobar et al. 2009; Marateb et al. 2011a).”
BackgroundMethodInfluentialSelf-citation
Cited by
Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647
Self-citationNeural Contributions to Muscle Fatigue: From the Brain to the Muscle and Back Again
TAYLOR, J. L., AMANN, M., DUCHATEAU, J., MEEUSEN, R., & RICE, C. L. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000923 · Cited by 543
Del Vecchio, A., Casolo, A., Negro, F., Scorcelletti, M., Bazzucchi, I., Enoka, R., Felici, F., & Farina, D. (2019) · The Journal of Physiology · doi:10.1113/jp277250 · Cited by 436
Self-citationFarina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359
Self-citationMorton, R. W., Sonne, M. W., Farias Zuniga, A., Mohammad, I. Y. Z., Jones, A., McGlory, C., Keir, P. J., Potvin, J. R., & Phillips, S. M. (2019) · The Journal of Physiology · doi:10.1113/jp278056 · Cited by 139
Flexible neural control of motor units
Marshall, N. J., Glaser, J. I., Trautmann, E. M., Amematsro, E. A., Perkins, S. M., Shadlen, M. N., Abbott, L. F., Cunningham, J. P., & Churchland, M. M. (2022) · Nature Neuroscience · doi:10.1038/s41593-022-01165-8 · Cited by 107
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Muceli, S., Poppendieck, W., Hoffmann, K.-P., Dosen, S., Benito-León, J., Barroso, F. O., Pons, J. L., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab047a · Cited by 33
Self-citationMuceli, S., Bergmeister, K. D., Hoffmann, K.-P., Aman, M., Vukajlija, I., Aszmann, O. C., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaed85 · Cited by 30
Self-citation
Metadata
- Authors
- Muceli, S., Poppendieck, W., Negro, F., Yoshida, K., Hoffmann, K. P., Butler, J. E., Gandevia, S. C., & Farina, D.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2015-09
- Volume
- 593
- Issue
- 17
- Pages
- 3789-3804
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1497541115
- Cited by
- 116
- References
- 7
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.