Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 296

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Changes in the maintained discharge with adaptation level in the cat retina

Open access
Barlow, H. B., Levick, W. R.·1969·The Journal of Physiology

Abstract

1. The mean rate, impulse interval distribution, and pulse number distribution of the maintained discharge of ganglion cells in the retina of the cat have been studied after prolonged adaptation at different luminance levels. 2. From a state of complete dark adaptation up to a luminance of about 5 × 10−3 cd/m 2 (viewed through a 7 mm 2 pupil) the mean rate of on‐centre units increases. From darkness up to a somewhat higher luminance the mean rate of some off‐centre units decreases, but others show little change. 3. Above 10−2 cd/m 2 the mean rate ceases to show a regular relation with adaptation level. On units often decrease and then increase again at a higher level. Rhythmical fluctuations are common near 10−2 cd/m 2, especially if the retina is not in first class condition. Mean rates above 70/sec and below 1/sec are very rare at any adaptation level. 4. Over the range where mean rate increases monotonically with adaptation level, it is shown that the surround of on‐centre units does not inhibit and off responses cannot be elicited. When the monotonic increase is slowed or reversed it becomes possible to elicit responses from the surround. We suspect that the surround exerts a sustained, tonic, inhibiting effect at higher adaptation levels, thus holding down the maintained discharge. 5. There are rare units, forming less than 1% of those isolated, that show a regularly increasing frequency with increase of adaptation level above 10−2 cd/m 2. These units have concentric ‘on’ and ‘off’ zones in their receptive fields, but the responses to rapidly changing stimuli are sluggish and they have an unusually regular maintained discharge. They have been tentatively called ‘luminance units’. 6. The impulse‐interval and pulse‐number distributions of on‐centre units change predictably with adaptation level; the variance of the pulse number distribution is usually several times the mean at very low adaptation levels, but only a fraction of the mean at high levels. Off‐centre units do not show predictable changes. Luminance units fire more regularly, and have narrower pulse‐number and impulse interval distributions than other concentric units. 7. A simple model is proposed to account for the statistical characteristics of the maintained discharge of on‐centre units.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1969.sp008836

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 296

Metadata

Authors
Barlow, H. B., & Levick, W. R.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1969-06
Volume
202
Issue
3
Pages
699-718
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2031725738
Cited by
296
References
12
FWCI
10.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Changes in the maintained discharge with adaptation level in the cat retina. https://app.cochat.ai/papers/10.1113/jphysiol.1969.sp008836
The paper
Barlow, H. B., & Levick, W. R. (1969). Changes in the maintained discharge with adaptation level in the cat retina. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1969.sp008836

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.