The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Changes in the maintained discharge with adaptation level in the cat retina
Open accessAbstract
1. The mean rate, impulse interval distribution, and pulse number distribution of the maintained discharge of ganglion cells in the retina of the cat have been studied after prolonged adaptation at different luminance levels. 2. From a state of complete dark adaptation up to a luminance of about 5 × 10−3 cd/m 2 (viewed through a 7 mm 2 pupil) the mean rate of on‐centre units increases. From darkness up to a somewhat higher luminance the mean rate of some off‐centre units decreases, but others show little change. 3. Above 10−2 cd/m 2 the mean rate ceases to show a regular relation with adaptation level. On units often decrease and then increase again at a higher level. Rhythmical fluctuations are common near 10−2 cd/m 2, especially if the retina is not in first class condition. Mean rates above 70/sec and below 1/sec are very rare at any adaptation level. 4. Over the range where mean rate increases monotonically with adaptation level, it is shown that the surround of on‐centre units does not inhibit and off responses cannot be elicited. When the monotonic increase is slowed or reversed it becomes possible to elicit responses from the surround. We suspect that the surround exerts a sustained, tonic, inhibiting effect at higher adaptation levels, thus holding down the maintained discharge. 5. There are rare units, forming less than 1% of those isolated, that show a regularly increasing frequency with increase of adaptation level above 10−2 cd/m 2. These units have concentric ‘on’ and ‘off’ zones in their receptive fields, but the responses to rapidly changing stimuli are sluggish and they have an unusually regular maintained discharge. They have been tentatively called ‘luminance units’. 6. The impulse‐interval and pulse‐number distributions of on‐centre units change predictably with adaptation level; the variance of the pulse number distribution is usually several times the mean at very low adaptation levels, but only a fraction of the mean at high levels. Off‐centre units do not show predictable changes. Luminance units fire more regularly, and have narrower pulse‐number and impulse interval distributions than other concentric units. 7. A simple model is proposed to account for the statistical characteristics of the maintained discharge of on‐centre units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DISCHARGE PATTERNS AND FUNCTIONAL ORGANIZATION OF MAMMALIAN RETINA
Kuffler, S. W. (1953) · Journal of Neurophysiology · doi:10.1152/jn.1953.16.1.37 · Cited by 2,609
Change of organization in the receptive fields of the cat's retina during dark adaptation
Barlow, H. B., Fitzhugh, R., & Kuffler, S. W. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005817 · Cited by 778
Self-citationIncrement thresholds at low intensities considered as signal/noise discriminations
Barlow, H. B. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005774 · Cited by 416
Self-citationAn Approach to the Quantitative Analysis of Electrophysiological Data from Single Neurons
Gerstein, G. L., & Kiang, N. Y.-S. (1960) · Biophysical Journal · doi:10.1016/s0006-3495(60)86872-5 · Cited by 393
MAINTAINED ACTIVITY IN THE CAT'S RETINA IN LIGHT AND DARKNESS
Kuffler, S. W., Fitzhugh, R., & Barlow, H. B. (1957) · The Journal of General Physiology · doi:10.1085/jgp.40.5.683 · Cited by 297
Self-citationMcIlwain, J. T. (1964) · Journal of Neurophysiology · doi:10.1152/jn.1964.27.6.1154 · Cited by 297
Three factors limiting the reliable detection of light by retinal ganglion cells of the cat
Barlow, H. B., & Levick, W. R. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008679 · Cited by 250
Self-citationMaintained activity of cat retinal ganglion cells.
Rodieck, R. W. (1967) · Journal of Neurophysiology · doi:10.1152/jn.1967.30.5.1043 · Cited by 201
The Role of Afterimages in Dark Adaptation
Barlow, H. B., & Sparrock, J. M. B. (1964) · Science · doi:10.1126/science.144.3624.1309 · Cited by 132
Self-citationStatistische Eigenschaften der Neuronaktivität im ascendierenden visuellen System
Herz, V. A., Creutzfeldt, O. D., & Fuster, J. M. (1964) · Kybernetik · doi:10.1007/bf00288559 · Cited by 83
Cited by
Dacey, D. M., Liao, H.-W., Peterson, B. B., Robinson, F. R., Smith, V. C., Pokorny, J., Yau, K.-W., & Gamlin, P. D. (2005) · Nature · doi:10.1038/nature03387 · Cited by 1,333
Parallel processing in the mammalian retina
Wässle, H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1497 · Cited by 1,252
How Does a Brain Build a Cognitive Code?
Grossberg, S. (1982) · Boston Studies in the Philosophy of Science · doi:10.1007/978-94-009-7758-7_1 · Cited by 1,192
Sustained and transient neurones in the cat's retina and lateral geniculate nucleus
Cleland, B. G., Dubin, M. W., & Levick, W. R. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009581 · Cited by 1,038
Self-citationSENSE AND THE SINGLE NEURON: Probing the Physiology of Perception
Parker, A. J., & Newsome, W. T. (1998) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.21.1.227 · Cited by 801
Strange vision: ganglion cells as circadian photoreceptors
Berson, D. (2003) · Trends in Neurosciences · doi:10.1016/s0166-2236(03)00130-9 · Cited by 546
Comparison of discharge variability in vitro and in vivo in cat visual cortex neurons
Holt, G. R., Softky, W. R., Koch, C., & Douglas, R. J. (1996) · Journal of Neurophysiology · doi:10.1152/jn.1996.75.5.1806 · Cited by 526
Fast and Slow Contrast Adaptation in Retinal Circuitry
Baccus, S. A., & Meister, M. (2002) · Neuron · doi:10.1016/s0896-6273(02)01050-4 · Cited by 515
Parallel visual pathways: A review
Lennie, P. (1980) · Vision Research · doi:10.1016/0042-6989(80)90115-7 · Cited by 509
The structure and precision of retinal spike trains
Berry, M. J., Warland, D. K., & Meister, M. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.10.5411 · Cited by 500
Brisk and sluggish concentrically organized ganglion cells in the cat's retina
Cleland, B. G., & Levick, W. R. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010617 · Cited by 487
Self-citationIntrinsically Photosensitive Retinal Ganglion Cells
Do, M. T. H., & Yau, K.-W. (2010) · Physiological Reviews · doi:10.1152/physrev.00013.2010 · Cited by 471
Meister, M., & Berry, M. J. (1999) · Neuron · doi:10.1016/s0896-6273(00)80700-x · Cited by 434
Cleland, B. G., & Levick, W. R. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010618 · Cited by 422
Self-citationBenosman, R., Clercq, C., Lagorce, X., Ieng, S.-H., & Bartolozzi, C. (2014) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2013.2273537 · Cited by 419
Low Response Variability in Simultaneously Recorded Retinal, Thalamic, and Cortical Neurons
Kara, P., Reinagel, P., & Reid, R. C. (2000) · Neuron · doi:10.1016/s0896-6273(00)00072-6 · Cited by 403
Contrast gain control in the cat visual cortex
Ohzawa, I., Sclar, G., & Freeman, R. D. (1982) · Nature · doi:10.1038/298266a0 · Cited by 348
The inner clock-Blue light sets the human rhythm
Wahl, S., Engelhardt, M., Schaupp, P., Lappe, C., & Ivanov, I. V. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201900102 · Cited by 293
Properties of sustained and transient ganglion cells in the cat retina
Cleland, B. G., Levick, W. R., & Sanderson, K. J. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010105 · Cited by 293
Self-citationResponses to single quanta of light in retinal ganglion cells of the cat
Barlow, H. B., Levick, W. R., & Yoon, M. (1971) · Vision Research · doi:10.1016/0042-6989(71)90033-2 · Cited by 277
Self-citationDoroudchi, M. M., Greenberg, K. P., Liu, J., Silka, K. A., Boyden, E. S., Lockridge, J. A., Arman, A. C., Janani, R., Boye, S. E., Boye, S. L., et al. (2011) · Molecular Therapy · doi:10.1038/mt.2011.69 · Cited by 277
Vickers, D., Nettelbeck, T., & Willson, R. J. (1972) · Perception · doi:10.1068/p010263 · Cited by 269
Synaptic influences on rat ganglion‐cell photoreceptors
Wong, K. Y., Dunn, F. A., Graham, D. M., & Berson, D. M. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.133751 · Cited by 267
Lateral interactions in the outer retina
Thoreson, W. B., & Mangel, S. C. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.04.003 · Cited by 262
A Role for Melanopsin in Alpha Retinal Ganglion Cells and Contrast Detection
Schmidt, T. M., Alam, N. M., Chen, S., Kofuji, P., Li, W., Prusky, G. T., & Hattar, S. (2014) · Neuron · doi:10.1016/j.neuron.2014.03.022 · Cited by 261
Tolhurst, D. J., Movshon, J. A., & Thompson, I. D. (1981) · Experimental Brain Research · doi:10.1007/bf00238900 · Cited by 260
Simultaneous contrast, filling-in process and information processing in man's visual system
Gerrits, H. J. M., & Vendrik, A. J. H. (1970) · Experimental Brain Research · doi:10.1007/bf00237914 · Cited by 257
Electrical induction of vision
Tehovnik, E. J., & Slocum, W. M. (2013) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.03.012 · Cited by 33
Metadata
- Authors
- Barlow, H. B., & Levick, W. R.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1969-06
- Volume
- 202
- Issue
- 3
- Pages
- 699-718
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2031725738
- Cited by
- 296
- References
- 12
- FWCI
- 10.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.