Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Human phase response curve to a single 6.5 h pulse of short‐wavelength light

Open access
Rüger, Melanie, St Hilaire, Melissa A., Brainard, George C., Khalsa, Sat‐Bir S., Kronauer, Richard E., Czeisler, Charles A., Lockley, Steven W. · 2013 · The Journal of Physiology

Abstract

Key points: The human ∼24 h circadian pacemaker ensures appropriate timing of physiological, behavioural and metabolic events and is synchronized to the 24 h day primarily by the 24 h light–dark cycle. The direction and magnitude of photic resetting depend on the timing of light exposure, and are described by a phase response curve (PRC). The human circadian photoreception system is functionally and anatomically distinct from the visual system and employs a novel photoreceptor, melanopsin, which is maximally sensitive to short‐wavelength (blue) visible light. We constructed a PRC to 6.5 h of blue (480 nm) light and compared it with a prior 6.7 h white light PRC; the blue light PRC achieved ∼75% of the resetting response of the white light PRC. This study suggests that short‐wavelength visible light exposures may be more efficient than traditional high‐intensity white light exposures for treatment of circadian rhythm sleep disorders. Abstract The photic resetting response of the human circadian pacemaker depends on the timing of exposure, and the direction and magnitude of the resulting shift is described by a phase response curve (PRC). Previous PRCs in humans have utilized high‐intensity polychromatic white light. Given that the circadian photoreception system is maximally sensitive to short‐wavelength visible light, the aim of the current study was to construct a PRC to blue (480 nm) light and compare it to a 10,000 lux white light PRC constructed previously using a similar protocol. Eighteen young healthy participants (18–30 years) were studied for 9–10 days in a time‐free environment. The protocol included three baseline days followed by a constant routine (CR) to assess initial circadian phase. Following this CR, participants were exposed to a 6.5 h 480 nm light exposure (11.8 μW cm−2, 11.2 lux) following mydriasis via a modified Ganzfeld dome. A second CR was conducted following the light exposure to re‐assess circadian phase. Phase shifts were calculated from the difference in dim light melatonin onset (DLMO) between CRs. Exposure to 6.5 h of 480 nm light resets the circadian pacemaker according to a conventional type 1 PRC with fitted maximum delays and advances of −2.6 h and 1.3 h, respectively. The 480 nm PRC induced ∼75% of the response of the 10,000 lux white light PRC. These results may contribute to a re‐evaluation of dosing guidelines for clinical light therapy and the use of light as a fatigue countermeasure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2012.239046

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 161

Metadata

Authors
Rüger, M., St Hilaire, M. A., Brainard, G. C., Khalsa, S. S., Kronauer, R. E., Czeisler, C. A., & Lockley, S. W.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2012-11-21
Volume
591
Issue
1
Pages
353-363
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1622456520
Cited by
161
References
16
FWCI
3.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human phase response curve to a single 6.5 h pulse of short‐wavelength light. https://app.cochat.ai/papers/10.1113/jphysiol.2012.239046
The paper
Rüger, M., St Hilaire, M. A., Brainard, G. C., Khalsa, S. S., Kronauer, R. E., Czeisler, C. A., & Lockley, S. W. (2013). Human phase response curve to a single 6.5 h pulse of short‐wavelength light. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2012.239046

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.