Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The chronic effects of a reshaping nerve electrode, the flat interface nerve electrode (FINE), on sciatic nerve physiology, histology, and blood-nerve barrier (BNB) are presented. The FINE electrode applies a small force to a nerve to reshape the nerve and fascicles into elongated ovals. This increases the interface between the nerve and electrode for selective stimulation and recording of peripheral nerve activity. The hypothesis of this study is that a small force applied noncircumferentially to a nerve can chronically reshape the nerve without effecting nerve physiology, histology, or the blood-nerve barrier permeability. Three FINE electrode designs were implanted on rat sciatic nerves to examine the nerve's response to small, moderate, and high reshaping forces. The chronic reshaping, physiology, and histology of the nerve were examined at 1, 7, and 28 days postimplant. All FINEs significantly reshape both the nerve and the fascicles compared to controls. FINEs that applied high forces caused a neurapraxia type injury characterized by changes in the animal's footprint, nerve histology, and the BNB permeability. The physiological changes were greatest at 7 days and fully recover to normal by 14 days postimplant. The moderate force FINE did not result in changes in the footprint or BNB permeability. Only a minor decrease in axon density without accompanying evidence of axon demyelination or regeneration was observe for the moderate force. The small force FINE does not caus…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrodes that moderately flattened the nerve demonstrated the best selectivity for limb motion measurements, which were maintained throughout the implant time (Tyler and Durand, 2003; Leventhal and Durand, 2004) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Tyler and Durand, 2003
In the citing paper
“Chronic studies in laboratory animals with FINE implanted over 1-3 months showed that electrodes applying high reshaping force induced nerve damage, whereas those with moderate and small forces did not cause any detectable change in nerve physiology and histology.”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Tyler and Durand, 2003
In the citing paper
“Here, nonpenetrating peripheral nerve cuff electrodes (14, 15) were shown to provide multiple tactile perceptions at multiple locations on the phantom hand in two upper limb amputees with stable responses for up to 24 months.”
From A neural interface provides long-term stable natural touch perception (2014) · cites this paper as [14]
In the citing paper
“However, the spatial resolution can be increased by using FINE, which reshapes the nerve and results in the electrodes having a closer proximity to the fascicles.”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Tyler and Durand, 2003
In the citing paper
“FINEs do have an acute effect on nerve functionality as a consequence of mechanical pressure, via changes in nerve myelination and axon density.”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Tyler and Durand, 2003
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The carpal tunnel syndrome. A study of carpal canal pressures.
Gelberman, R. H., Hergenroeder, P. T., Hargens, A. R., Lundborg, G. N., & Akeson, W. H. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163030-00009 · Cited by 744
Pathoanatomy and Pathophysiology of Nerve Root Compression
RYDEVIK, B., BROWN, M. D., & LUNDBORG, G. (1984) · Spine · doi:10.1097/00007632-198401000-00004 · Cited by 503
Effects of graded compression on intraneural blood flow
Rydevik, B., Lundborg, G., & Bagge, U. (1981) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(81)80003-2 · Cited by 465
Lundborg, G., Myers, R., & Powell, H. (1983) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.46.12.1119 · Cited by 316
Rydevik, B., & Lundborg, G. (1977) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844317709025516 · Cited by 289
Olsson, Y. (1966) · Acta Neuropathologica · doi:10.1007/bf00686605 · Cited by 232
Selective Vulnerability of the Blood-Brain Barrier in Chemically Induced Lesions*
Steinwall, O., & Klatzo, I. (1966) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/00005072-196610000-00004 · Cited by 225
ANATOMY, FUNCTION, AND PATHOPHYSIOLOGY OF PERIPHERAL NERVES AND NERVE COMPRESSION
Lundborg, G., & Dahlin, L. B. (1996) · Hand Clinics · doi:10.1016/s0749-0712(21)00303-6 · Cited by 201
Pathology of experimental nerve compression.
Powell, H. C., & Myers, R. R. (1986) · PubMed · Cited by 195
An experimental painful peripheral neuropathy due to nerve constriction
Munger, B. L., Bennett, G. J., & Kajander, K. C. (1992) · Experimental Neurology · doi:10.1016/0014-4886(92)90037-q · Cited by 129
Cited by
Items 101–145 of 145
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091011 · Cited by 7
“change shape, though this has been demonstrated in animal trials [21].”
Self-citationComputational modeling of human vagus nerve stimulation with three-dimensional fascicular morphology
Marshall, D. P., Upadhye, A. R., Buyukcelik, O. N., Shoffstall, A. J., Grill, W. M., & Pelot, N. A. (2026) · APL Bioengineering · doi:10.1063/5.0308450 · Cited by 9
Koppaka, S. (2013) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 4
Effects of the choice of reference on the selectivity of a multi-contact nerve cuff electrode
Koh, R. G. L., & Zariffa, J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591713 · Cited by 6
“This improvement along with novel strategies such as nerve reshaping [10][12] or the use of source localization techniques [13][14] have demonstrated that nerve activity from different fascicles can indeed be discriminated using a nerve cuff electrode.”
BackgroundGupta, S., Ghatak, S., Hery, T. M., Khanna, S., Masry, M. S. E., Sundaresan, V.-B., & Sen, C. K. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112618 · Cited by 4
Tyler, D. J., Polasek, K. H., & Schiefer, M. A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-802653-3.00112-3 · Cited by 10
Self-citationSensing Nerve Activity with Scalable and Robust Nerve Interfaces
Kuliasha, C. A., Spearman, B. S., Atkinson, E. W., Rustogi, P., Fumiturewalla, A. S., Nunamaker, E. A., Otto, K. J., Schmidt, C. E., & Judy, J. W. (2019) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors43011.2019.8956532 · Cited by 4
CLINICAL IMPLEMENTATION OF NERVE CUFF ELECTRODES FOR AN UPPER EXTREMITY NEUROPROSTHESIS
Polasek, K. H. (2007) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
Schiefer, M. A., Triolo, R. J., Durand, D. M., & Tyler, D. J. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419631 · Cited by 4
“Contacts had a stimulating surface 0.5 mm x 0.5 mm with 0.5 mm between them [11, 12 ].”
BackgroundInfluentialSelf-citationMethods of integrating the human nervous system with electronic circuits
Skok, T., Tabakow, P., & Chmielak, K. (2019) · Advances in Clinical and Experimental Medicine · doi:10.17219/acem/103414 · Cited by 3
Artificially-Intelligent Fascicle-Selective Bidirectional Peripheral Nerve Interfaces
Xu, J., Filho, J. D. S., Hwang, E., Nag, S., Long, L., Kanchwala, M., Abdolrazzaghi, M., Huang, Y. T., Zariffa, J., & Genov, R. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388693 · Cited by 3
“Minimal compression is exerted on the nerve to ensure optimal planar array contact, akin to the passive FINE electrodes routinely implanted in humans [7].”
BackgroundSchiefer, M. A. (2009) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
Developing Conductive Materials for Peripheral Nerve Interfaces
Zhang, H., Lü, L., Wang, Y., & Zhao, Y. (2025) · Small Methods · doi:10.1002/smtd.202501219 · Cited by 5
Somatosensory Neuromodulation with a Focus Towards Clinical Systems
Graczyk, E. L., & Tyler, D. J. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_92-1 · Cited by 2
Self-citationHigh-fidelity interfacing for bionic rehabilitation
Vujaklija, I. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-23987-8.00003-1 · Cited by 3
Wodlinger, B., Dweiri, Y. M., & Durand, D. M. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-26208-8.00009-1 · Cited by 4
Self-citationNeural electrodes for long-term tissue interfaces
del Valle, J., Rodríguez‐Meana, B., & Navarro, X. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00009-5 · Cited by 2
Bioelectronics and Neural Interfaces
Tong, W., Robles, U. A. A., & Gelmi, A. A. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781788019828-00180 · Cited by 2
Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve
Chandra, N. S., McCarron, W. M., Yan, Y., Ruiz, L. C., Sallinger, E. G., Birenbaum, N. K., Burton, H., Green, L., Moran, D. W., Ray, W. Z., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.758427 · Cited by 2
Neural Interfacing with the Peripheral Nervous System: A FINE Approach
Durand, D. M., Wodlinger, B., & Park, H. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5227-0_16 · Cited by 2
Self-citationVENTRAL ROOT OR DORSAL ROOT GANGLION MICROSTIMULATION TO EVOKE HINDLIMB MOTOR RESPONSES
Bourbeau, D. J. (2011) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2
Bioelectric source localization in peripheral nerves.
Zariffa, J. (2010) · Library and Archives Canada (Government of Canada) · Cited by 5
Discrimination of Neural Sources using Spatiotemporal Signatures in Nerve Cuff Electrode Recordings
Koh, R. G. L. (2019) · TSpace (University of Toronto) · Cited by 2
Long-term upper-extremity prosthetic control using Regenerative Peripheral Nerve InterfacesPreprint
Vu, P. P., Vaskov, A. K., Lee, C., Jillala, R., Davis, A. J., Kung, T. A., Kemp, S. W. P., Gates, D. H., Chestek, C. A., & Cederna, P. S. (2022) · Research Square · doi:10.21203/rs.3.rs-1578680/v1 · Cited by 2
A Multi-lead Multi-electrode System for Neural-interface Enabled Advanced Prostheses
Thota, A. K., Kuntaegowdanahalli, S. S., Orbay, J. L., Starosciak, A. K., Abbas, J. J., Horch, K. W., & Jung, R. (2013) · Southern Biomedical Engineering Conference (SBEC) · doi:10.1109/sbec.2013.63 · Cited by 1
Biotic‐Abiotic Interface Engineering for Peripheral Nerve Modulation and Repair
Jekal, J., Park, J. T., Kim, E., Lee, Y., & Jang, K. (2025) · Small Methods · doi:10.1002/smtd.202501620 · Cited by 2
Somatosensory Neuromodulation with a Focus Towards Clinical Systems
Graczyk, E. L., & Tyler, D. J. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_92 · Cited by 1
Self-citationKundu, A., Patrick, E. E., Currlin, S., Madler, R., Delgado, F., Fahmy, A., Verplancke, R., Ballini, M., Braeken, D., de Beeck, M. O., et al. (2024) · Micromachines · doi:10.3390/mi15020280 · Cited by 1
Ramped kilohertz-frequency signals produce nerve conduction block without onset response
Peña, E., Pelot, N. A., & Grill, W. M. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/add20e · Cited by 2
“We modeled the nerve as a cylinder (50 mm length; 0.75 mm diameter (Schmalbruch 1986, Tyler and Durand 2003)).”
InfluentialBiomimetic Electrospun Fibers for Peripheral Nervous System Repair.
Leach, M. K. (2013) · Cited by 1
Herrera‐Rincon, C., Cisneros, F. J., Castellanos, J., & Panetsos, F. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910628 · Cited by 1
“However, very few studies addressed the effect of neuroprosthetic stimulation on the morphology and organization of the peripheral nerves in the neural interface [ 2 ].”
BackgroundThe Science in Science Fiction's Artificial Men
Englehart, K. B., & MacIsaac, D. (2006) · Cited by 6
Progress in Peripheral Neural Interfaces
Qiao, S., Mauser, K. A., & Yoshida, K. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch4 · Cited by 1
Controlled reshaping of nerve geometry
Caparso, A., & Durand, D. M. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280174
Self-citationRegenerative Peripheral Neurointerfacing Of Upper Extremity Prostheses
Garde, K. (2008) · UTA ResearchCommons (University of Texas Arlington)
Forrest, A. (2011) · University of Minnesota Digital Conservancy (University of Minnesota)
canine upper airway mechanics Effects of selective hypoglossal nerve stimulation on
Yoo, P. B., Durand, D. M., Oliven, A., Odeh, M., Oliven, R., Steinfeld, U., Schwartz, A. R., THORSON, M., Ducharme, N. G., Cheetham, J., et al. (2015)
Self-citationYoo, P. B. (2004) · OhioLink ETD Center (Ohio Library and Information Network)
A Validated Peripheral Nerve Model for the Simulation of Multicontact Nerve Cuff Recordings
Garai, P. (2016) · TSpace (University of Toronto)
Dynamic Laryngo-Tracheal Control for Airway Management in Dysphagia
Hadley, A. J. (2013) · OhioLink ETD Center (Ohio Library and Information Network)
On the Use of Subdermal Electrical Stimulation for Restoration of Sensory Feedback
Dong, J. C. (2020) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau533906290
Lim, J., Ward, M. P., Furness, J. B., et al. (2022) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2022.26
Direct carotid sinus nerve stimulation in anesthetized human subjects
Majerus, S. J. A., Pinault, G. C. J., Tyler, D. J., Dunning, J. L., Schlesinger, R., Heald, E., & Baskin, J. Z. (2025) · Scientific Reports · doi:10.1038/s41598-025-10091-1
“Importantly, prior studies have shown that when the electrode is secured, the applied pressure does not compromise blood flow to nerve tissue 23,34,35 .”
Self-citationAnalyse et modélisation de l'activité électrophysiologique par la méthode de Matrix Pencil
Mizouri, Z. (2021) · theses.fr (ABES) · doi:10.70675/673bb96bz92b5z4efcz9fe3z633b191e8995
Metadata
- Authors
- Tyler, D. J., & Durand, D. M.
- Affiliations
- Case Western Reserve University (US)
- Venue
- Annals of Biomedical Engineering
- Published
- 2003-06
- Volume
- 31
- Issue
- 6
- Pages
- 633-642
- ISSN
- 0090-6964 (ISSN-L)
- OpenAlex
- W2062755405
- Cited by
- 144
- References
- 23
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 4 · 2023: 9 · 2022: 6 · 2021: 14 · 2020: 9 · 2019: 8 · 2018: 4 · 2017: 8 · 2016: 12 · 2015: 7 · 2014: 2 · 2013: 13 · 2012: 5
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (NS32845, R01NS032845)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Keywords
- sciatic nerve, peripheral nerve stimulation, neuropraxia, nerve histology, axon density, peripheral nerve recording
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Implanted, Foot, Gait, Male, Nerve Compression Syndromes, Prosthesis Design, Sciatic Nerve, Stress, Mechanical, Rats, Sprague-Dawley, Equipment Failure Analysis, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.