The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Effect of Fiber Orientation and Strain Rate on the Nonlinear Uniaxial Tensile Material Properties of Tendon
Abstract
Tendons are exposed to complex loading scenarios that can only be quantified by mathematical models, requiring a full knowledge of tendon mechanical properties. This study measured the anisotropic, nonlinear, elastic material properties of tendon. Previous studies have primarily used constant strain-rate tensile tests to determine elastic modulus in the fiber direction. Data for Poisson’s ratio aligned with the fiber direction and all material properties transverse to the fiber direction are sparse. Additionally, it is not known whether quasi-static constant strain-rate tests represent equilibrium elastic tissue behavior. Incremental stress-relaxation and constant strain-rate tensile tests were performed on sheep flexor tendon samples aligned with the tendon fiber direction or transverse to the fiber direction to determine the anisotropic properties of toe-region modulus E0, linear-region modulus (E), and Poisson’s ratio (ν). Among the modulus values calculated, only fiber-aligned linear-region modulus E1 was found to be strain-rate dependent. The E1 calculated from the constant strain-rate tests were significantly greater than the value calculated from incremental stress-relaxation testing. Fiber-aligned toe-region modulus E10=10.5±4.7 MPa and linear-region modulus E1=34.0±15.5 MPa were consistently 2 orders of magnitude greater than transverse moduli (E20=0.055±0.044 MPa,E2=0.157±0.154 MPa). Poisson’s ratio values were not found to be rate-dependent in either the fiber-aligned (ν12=2.98±2.59, n=24) or transverse (ν21=0.488±0.653, n=22) directions, and average Poisson’s ratio values in the fiber-aligned direction were six times greater than in the transverse direction. The lack of strain-rate dependence of transverse properties demonstrates that slow constant strain-rate tests represent elastic properties in the transverse direction. However, the strain-rate dependence demonstrated by the fiber-aligned linear-region modulus suggests that incremental stress-relaxation tests are necessary to determine the equilibrium elastic properties of tendon, and may be more appropriate for determining the properties to be used in elastic mathematical models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NOYES, F. R., DELUCAS, J. L., & TORVIK, P. J. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456020-00002 · Cited by 656
Depth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646
Akizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040401 · Cited by 504
Mechanical properties of the human achilles tendon
Wren, T. A. L., Yerby, S. A., Beaupré, G. S., & Carter, D. R. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00089-9 · Cited by 466
Material Characterization of Human Medial Collateral Ligament
Quapp, K. M., & Weiss, J. A. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834890 · Cited by 351
Guilak, F., Ratcliffe, A., Lane, N., Rosenwasser, M. P., & Mow, V. C. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120404 · Cited by 335
Functional Properties of Collagenous Tissues
Viidik, A. (1973) · International Review of Connective Tissue Research · doi:10.1016/b978-0-12-363706-2.50010-6 · Cited by 317
Degeneration and Aging Affect the Tensile Behavior of Human Lumbar Anulus Fibrosus
Acaroglu, E. R., Latridis, J. C., Setton, L. A., Foster, R. J., Mow, V. C., & Weidenbaum, A. M. (1995) · Spine · doi:10.1097/00007632-199512150-00010 · Cited by 303
Recruitment of Tendon Crimp With Applied Tensile Strain
Hansen, K. A., Weiss, J. A., & Barton, J. K. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427698 · Cited by 285
Setton, L. A., Mow, V. C., Müller, F. J., Pita, J. C., & Howell, D. S. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120402 · Cited by 227
Ligament material behavior is nonlinear, viscoelastic and rate-independent under shear loading
Weiss, J. A., Gardiner, J. C., & Bonifasi-Lista, C. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00041-6 · Cited by 210
Regional material properties of the human hip joint capsule ligaments
Hewitt, J., Guilak, F., Glisson, R. R., & Vail, T. P. (2001) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(00)00035-8 · Cited by 196
Danto, M. I., & Woo, S. L. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110108 · Cited by 193
Woo, S. L., Peterson, R. H., Ohland, K. J., Sites, T. J., & Danto, M. I. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080513 · Cited by 176
Haut, T. L., & Haut, R. C. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00108-x · Cited by 140
Stress governs tissue phenotype at the femoral insertion of the rabbit MCL
Matyas, J. R., Anton, M. G., Shrive, N. G., & Frank, C. B. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00058-c · Cited by 130
Role of Storage on Changes in the Mechanical Properties of Tendon and Self-Assembled Collagen Fibers
Silver, F. H., Christiansen, D. L., Snowhill, P. B., et al. (2000) · Connective Tissue Research · doi:10.3109/03008200009067667 · Cited by 121
Elliott, D. M., Guilak, F., Vail, T. P., Wang, J. Y., & Setton, L. A. (1999) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100170407 · Cited by 119
Self-citationMechanical Properties of Human Tendon and Their Age Dependence
Hubbard, R. P., & Soutas-Little, R. W. (1984) · Journal of Biomechanical Engineering · doi:10.1115/1.3138471 · Cited by 78
Effects of Stress Shielding on the Transverse Mechanical Properties of Rabbit Patellar Tendons
YAMAMOTO, E., Hayashi, K., & Yamamoto, N. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1319660 · Cited by 45
Cited by
Baker, B. M., Gee, A. O., Metter, R. B., Nathan, A. S., Marklein, R. A., Burdick, J. A., & Mauck, R. L. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.032 · Cited by 620
Pathogenesis of tendinopathies: inflammation or degeneration?
Abate, M., Gravare-Silbernagel, K., Siljeholm, C., Di Iorio, A., De Amicis, D., Salini, V., Werner, S., & Paganelli, R. (2009) · Arthritis Research & Therapy · doi:10.1186/ar2723 · Cited by 571
Provenzano, P. P., Inman, D. R., Eliceiri, K. W., Trier, S. M., & Keely, P. J. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.133116 · Cited by 493
Stiffness Gradients Mimicking In Vivo Tissue Variation Regulate Mesenchymal Stem Cell Fate
Tse, J. R., & Engler, A. J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0015978 · Cited by 455
Li, W.-J., Mauck, R. L., Cooper, J. A., Yuan, X., & Tuan, R. S. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.004 · Cited by 400
Metadata
- Authors
- Lynch, H. A., Johannessen, W., Wu, J. P., Jawa, A., & Elliott, D. M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2003-10-01
- Volume
- 125
- Issue
- 5
- Pages
- 726-731
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2003901870
- Cited by
- 272
- References
- 20
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.