The DOI matches its Crossref record.
Shear Properties of Human Brain Tissue
Abstract
The objective of this study was to determine a relationship between shear stress and strain for human brain tissue by performing transient, single-pulse, high-rate, shear displacement tests. A constant velocity, parallel plate shear test device was designed and fabricated. This equipment generated constant rate shear strains in cylindrical tissue samples mounted between the shear plates. The transverse reaction force at the upper end of the sample was measured during the event with a sensitive quartz piezoelectric force transducer, thus obtaining the force associated with the displacement versus time ramp. Shear tests were performed on 125 tissue samples taken from twelve fresh cadaver brain specimens. The average true shear stress and finite strain were calculated. A nonlinear, viscoelastic, standard solid model was fit to the constant rate test data and the material constants were determined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanical characterization of human brain tissue
Budday, S., Sommer, G., Birkl, C., Langkammer, C., Haybaeck, J., Kohnert, J., Bauer, M., Paulsen, F., Steinmann, P., Kuhl, E., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.036 · Cited by 656
Regional, Directional, and Age-Dependent Properties of the Brain Undergoing Large Deformation
Prange, M. T., & Margulies, S. S. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449907 · Cited by 635
Mechanical properties of brain tissue in tension
Miller, K., & Chinzei, K. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00234-2 · Cited by 635
Mechanical properties of brain tissue in-vivo: experiment and computer simulation
Miller, K., Chinzei, K., Orssengo, G., & Bednarz, P. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00120-2 · Cited by 501
Fifty Shades of Brain: A Review on the Mechanical Testing and Modeling of Brain Tissue
Budday, S., Ovaert, T. C., Holzapfel, G. A., Steinmann, P., & Kuhl, E. (2020) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-019-09352-w · Cited by 469
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
Meaney, D. F., & Smith, D. H. (2011) · Clinics in Sports Medicine · doi:10.1016/j.csm.2010.08.009 · Cited by 425
Magnetic resonance elastography of the brain
Kruse, S. A., Rose, G. H., Glaser, K. J., Manduca, A., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.030 · Cited by 424
Brain tissue deforms similarly to filled elastomers and follows consolidation theory
Franceschini, G., Bigoni, D., Regitnig, P., & Holzapfel, G. A. (2006) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2006.05.004 · Cited by 385
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
“Unlike impact injury modeling [36, 37] or modeling surgical procedures [35, 38], this modeling of the brain is different because of the small strain rates (in the order of 10−6 s−1) and small displacements involved (2–20 μm).”
MethodMechanics of the brain: perspectives, challenges, and opportunities
Goriely, A., Geers, M. G. D., Holzapfel, G. A., Jayamohan, J., Jérusalem, A., Sivaloganathan, S., Squier, W., van Dommelen, J. A. W., Waters, S., & Kuhl, E. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0662-4 · Cited by 371
On the Development of the SIMon Finite Element Head Model
Takhounts, E. G., Eppinger, R. H., Campbell, J. Q., Tannous, R. E., Power, E. D., & Shook, L. S. (2003) · SAE Technical Paper Series · doi:10.4271/2003-22-0007 · Cited by 350
Mechanical Heterogeneity of the Rat Hippocampus Measured by Atomic Force Microscope Indentation
Elkin, B. S., Azeloglu, E. U., Costa, K. D., & Morrison III, B. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2006.0169 · Cited by 316
Thibault, K. L., & Margulies, S. S. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00122-5 · Cited by 299
Ghajari, M., Hellyer, P. J., & Sharp, D. J. (2017) · Brain · doi:10.1093/brain/aww317 · Cited by 280
Constitutive model of brain tissue suitable for finite element analysis of surgical procedures
Miller, K. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00010-x · Cited by 263
Viscoelastic parameter identification of human brain tissue
Budday, S., Sommer, G., Holzapfel, G. A., Steinmann, P., & Kuhl, E. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.07.014 · Cited by 178
Computational assessment of neural probe and brain tissue interface under transient motion.
Polanco, M., Bawab, S., & Yoon, H. (2016) · Biosensors · doi:10.3390/bios6020027 · Cited by 36
“The shear properties utilized for this study account for the stiffness in the brain due to ventricles, and, as stated by [56], the ratio between bulk and shear moduli is approximately 105, to define the incompressible nature of the brain and its low stiffness in shear.”
Method
Metadata
- Authors
- Donnelly, B. R., & Medige, J.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1997-11-01
- Volume
- 119
- Issue
- 4
- Pages
- 423-432
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2168538714
- Cited by
- 237
- References
- 0
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.