The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Analysis of Indentation: Implications for Measuring Mechanical Properties With Atomic Force Microscopy
Abstract
Indentation using the atomic force microscope (AFM) has potential to measure detailed micromechanical properties of soft biological samples. However, interpretation of the results is complicated by the tapered shape of the AFM probe tip, and its small size relative to the depth of indentation. Finite element models (FEMs) were used to examine effects of indentation depth, tip geometry, and material nonlinearity and heterogeneity on the finite indentation response. Widely applied infinitesimal strain models agreed with FEM results for linear elastic materials, but yielded substantial errors in the estimated properties for nonlinear elastic materials. By accounting for the indenter geometry to compute an apparent elastic modulus as a function of indentation depth, nonlinearity and heterogeneity of material properties may be identified. Furthermore, combined finite indentation and biaxial stretch may reveal the specific functional form of the constitutive law—a requirement for quantitative estimates of material constants to be extracted from AFM indentation data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johnson, K. L. (1985) · Cambridge University Press eBooks · doi:10.1017/cbo9781139171731 · Cited by 7,796
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Ueber die Berührung fester elastischer Körper.
Hertz, H. (1882) · crll · doi:10.1515/crll.1882.92.156 · Cited by 4,789
Sneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346
A method for interpreting the data from depth-sensing indentation instruments
Doerner, M. F., & Nix, W. D. (1986) · Journal of Materials Research · doi:10.1557/jmr.1986.0601 · Cited by 2,863
Focal Adhesions: Transmembrane Junctions Between the Extracellular Matrix and the Cytoskeleton
Burridge, K., Fath, K., Kelly, T., Nuckolls, G., & Turner, C. (1988) · Annual Review of Cell Biology · doi:10.1146/annurev.cb.04.110188.002415 · Cited by 2,120
Finite Elements of Nonlinear Continua
Oden, J. T. (1971) · International Linear Collider · Cited by 992
A mathematical analysis for indentation tests of articular cartilage
Hayes, W. C., Keer, L. M., Herrmann, G., & Mockros, L. F. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90010-3 · Cited by 967
Measuring the viscoelastic properties of human platelets with the atomic force microscope
Radmacher, M., Fritz, M., Kacher, C. M., Cleveland, J. P., & Hansma, P. K. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79602-9 · Cited by 839
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Relative Microelastic Mapping of Living Cells by Atomic Force Microscopy
A-Hassan, E., Heinz, W. F., Antonik, M. D., D’Costa, N. P., Nageswaran, S., Schoenenberger, C.-A., & Hoh, J. H. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77868-3 · Cited by 552
Biphasic indentation of articular cartilage—I. Theoretical analysis
Mak, A. F., Lai, W. M., & Mow, V. C. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90036-4 · Cited by 478
Deformation and height anomaly of soft surfaces studied with an AFM
Weisenhorn, A. L., Khorsandi, M., Kasas, S., Gotzos, V, & Butt, H. J. (1993) · Nanotechnology · doi:10.1088/0957-4484/4/2/006 · Cited by 427
Surface morphology and mechanical properties of MDCK monolayers by atomic force microscopy
Hoh, J. H., & Schoenenberger, C.-A. (1994) · Journal of Cell Science · doi:10.1242/jcs.107.5.1105 · Cited by 418
Measuring the elastic properties of biological samples with the AFM
Radmacher, M. (1997) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.582176 · Cited by 417
Imaging soft samples with the atomic force microscope: gelatin in water and propanol
Radmacher, M., Fritz, M., & Hansma, P. K. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)79897-6 · Cited by 379
Bilodeau, G. G. (1992) · Journal of Applied Mechanics · doi:10.1115/1.2893754 · Cited by 265
Investigating the Cytoskeleton of Chicken Cardiocytes with the Atomic Force Microscope
Hofmann, U. G., Rotsch, C., Parak, W. J., & Radmacher, M. (1997) · Journal of Structural Biology · doi:10.1006/jsbi.1997.3868 · Cited by 199
Determination of Cellular Mechanical Properties by Cell Poking, With an Application to Leukocytes
Zahalak, G. I., McConnaughey, W. B., & Elson, E. L. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891186 · Cited by 148
Poggi, M. A., Gadsby, E. D., Bottomley, L. A., King, W. P., Oroudjev, E., & Hansma, H. G. (2004) · Analytical Chemistry · doi:10.1021/ac0400818 · Cited by 119
Bottomley, L. A., Coury, J. E., & First, P. N. (1996) · Analytical Chemistry · doi:10.1021/a1960008+ · Cited by 90
Schaus, S., & Henderson, E. R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78153-0 · Cited by 85
Membrane deformation of living glial cells using atomic force microscopy
Haydon, P. G., Lartius, R. K., Parpura, V., & Marchese‐Ragona, S. P. (1996) · Journal of Microscopy · doi:10.1046/j.1365-2818.1996.141423.x · Cited by 78
A numerical solution for axisymmetric contact problems involving rigid indenters on elastic layers
Jaffar, M. J. (1988) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(88)90025-7 · Cited by 60
Cell poking: quantitative analysis of indentation of thick viscoelastic layers
Duszyk, M., Schwab, B., Zahalak, G. I., Qian, H., & Elson, E. L. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82867-x · Cited by 55
Karduna, A. R., Halperin, H. R., & Yin, F. C. P. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684136 · Cited by 43
Self-citation
Cited by
Determination of Elastic Moduli of Thin Layers of Soft Material Using the Atomic Force Microscope
Dimitriadis, E. K., Horkay, F., Maresca, J., Kachar, B., & Chadwick, R. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75620-8 · Cited by 1,230
Atomic force microscopy probing of cell elasticity
Kuznetsova, T. G., Starodubtseva, M. N., Yegorenkov, N. I., Chizhik, S. A., & Zhdanov, R. I. (2007) · Micron · doi:10.1016/j.micron.2007.06.011 · Cited by 794
Microrheology of Human Lung Epithelial Cells Measured by Atomic Force Microscopy
Alcaraz, J., Buscemi, L., Grabulosa, M., Trepat, X., Fabry, B., Farré, R., & Navajas, D. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75014-0 · Cited by 740
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Mathur, A. B., Collinsworth, A. M., Reichert, W. M., Kraus, W. E., & Truskey, G. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00149-x · Cited by 589
Metadata
- Authors
- Costa, K. D., & Yin, F. C. P.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1999-10-01
- Volume
- 121
- Issue
- 5
- Pages
- 462-471
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2080695242
- Cited by
- 265
- References
- 26
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.