The Effect of Static and Dynamic Loading on Degradation of PLLA Stent Fibers
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Understanding how polymers such as PLLA degrade in vivo will enhance biodegradable stent design. This study examined the effect of static and dynamic loads on PLLA stent fibers in vitro. The stent fibers (generously provided by TissueGen, Inc.) were loaded axially with 0 N, 0.5 N, 1 N, or 0.125–0.25 N (dynamic group, 1 Hz) and degraded in PBS at 45 °C for an equivalent degradation time of 15 months. Degradation was quantified through changes in tensile mechanical properties. The mechanical behavior was characterized using the Knowles strain energy function and a degradation model. A nonsignificant increase in fiber stiffness was observed between 0 and 6 months followed by fiber softening thereafter. A marker of fiber softening, β, increased between 9 and 15 months in all groups. At 15 months, the β values in the dynamic group were significantly higher compared to the other groups. In addition, the model indicated that the degradation rate constant was smaller in the 1-N (0.257) and dynamic (0.283) groups compared to the 0.5-N (0.516) and 0-N (0.406) groups. While the shear modulus fluctuated throughout degradation, no significant differences were observed. Our results indicate that an increase in static load increased the degradation of mechanical properties and that the application of dynamic load further accelerated this degradation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Mechanisms of polymer degradation and erosion
Göpferich, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85755-3 · Cited by 1,781
Cardiovascular Solid Mechanics: Cells, Tissues, and Organs
Humphrey, J., & Epstein, M. (2002) · Applied Mechanics Reviews · doi:10.1115/1.1497492 · Cited by 1,159
Hydrolytic degradation of devices based on poly(DL-lactic acid) size-dependence
Grizzi, I., Garreau, H., Li, S., & Vert, M. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93258-f · Cited by 895
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Li, S. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:3<246::aid-jbm7>3.0.co;2-x · Cited by 671
Li, S. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:3<342::aid-jbm20>3.0.co;2-7 · Cited by 664
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Water absorption and enzymatic degradation of poly(lactic acid)/rice starch composites
Yew, G. H., Mohd Yusof, A. M., Mohd Ishak, Z. A., & Ishiaku, U. S. (2005) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2005.04.006 · Cited by 374
Tsuji, H., & Ikada, Y. (2000) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(99)00111-1 · Cited by 329
Resorbable materials of poly(l-lactide)
Leenslag, J. W., Pennings, A. J., Bos, R. R. M., Rozema, F. R., & Boering, G. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90121-9 · Cited by 329
Knowles, J. K. (1977) · International Journal of Fracture · doi:10.1007/bf00017296 · Cited by 292
Application of the Arrhenius equation to solid state kinetics: can this be justified?
Galwey, A. K., & Brown, M. E. (2002) · Thermochimica Acta · doi:10.1016/s0040-6031(01)00769-9 · Cited by 250
Nishio, S., Kosuga, K., Igaki, K., Okada, M., Kyo, E., Tsuji, T., Takeuchi, E., Inuzuka, Y., Takeda, S., Hata, T., et al. (2012) · Circulation · doi:10.1161/circulationaha.110.000901 · Cited by 240
Kinetics and Time−Temperature Equivalence of Polymer Degradation
Lyu, Schley, J., Loy, B., Lind, D., Hobot, C., Sparer, R., & Untereker, D. (2007) · Biomacromolecules · doi:10.1021/bm070313n · Cited by 237
Mano, J. F., Gómez Ribelles, J. L., Alves, N. M., & Salmerón Sanchez, M. (2005) · Polymer · doi:10.1016/j.polymer.2005.06.096 · Cited by 180
Biodegradable stents with elastic memory
Venkatraman, S. S., Tan, L. P., Joso, J. F. D., Boey, Y. C. F., & Wang, X. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.002 · Cited by 178
Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
VOGT, F. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.010 · Cited by 174
Degradation of poly-L-lactide. Part 2: increased temperature accelerated degradation
Weir, N. A., Buchanan, F. J., Orr, J. F., Farrar, D. F., & Dickson, G. R. (2004) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411041932809 · Cited by 171
Effects of Stent Design Parameters on Normal Artery Wall Mechanics
Bedoya, J. J., Meyer, C. A., Timmins, L. H., Moreno, M. R., & Moore, J. E. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2246236 · Cited by 139
Self-citationElevated temperature degradation of a 50:50 copolymer of PLA-PGA
Agrawal, C. M., Huang, D., Schmitz, J. P., & Athanasiou, K. A. (1997) · Tissue Engineering · doi:10.1089/ten.1997.3.345 · Cited by 120
ABSORB II randomized controlled trial
Diletti, R., Serruys, P. W. J. C., Farooq, V., Sudhir, K., Dorange, C., Miquel‐Hébert, K., Veldhof, S., Rapoza, R. R., Onuma, Y., García‐García, H. M., et al. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.08.010 · Cited by 114
Onuma, Y., Serruys, P. W. J. C., Gomez, J., Bruyne, B. D., Dudek, D., Thuesen, L., Smits, P., Chevalier, B., McClean, D., Koolen, J., et al. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22864 · Cited by 110
Constitutive Framework for Biodegradable Polymers with Applications to Biodegradable Stents
Soares, J. S., Moore, J. E., & Rajagopal, K. R. (2008) · ASAIO Journal · doi:10.1097/mat.0b013e31816ba55a · Cited by 106
Self-citationOn the shear and bending of a degrading polymer beam
Rajagopal, K. R., Srinivasa, A. R., & Wineman, A. S. (2007) · International Journal of Plasticity · doi:10.1016/j.ijplas.2007.02.007 · Cited by 95
Yuan, X., Mak, A. F. T., & Yao, K. (2002) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(01)00203-8 · Cited by 88
Modeling the response of nonlinear viscoelastic biodegradable polymeric stents
Muliana, A. H., & Rajagopal, K. R. (2012) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2011.12.007 · Cited by 78
In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages
van Dijk, M., Tunc, D. C., Smit, T. H., Higham, P., Burger, E. H., & Wuisman, P. I. J. M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10466 · Cited by 78
Okamura, T., Garg, S., Gutiérrez‐Chico, J. L., Shin, E., Onuma, Y., García‐García, H. M., Rapoza, R. J., Sudhir, K., Regar, E. S., & Serruys, P. W. J. C. (2010) · EuroIntervention · doi:10.4244/eijv5i8a157 · Cited by 76
Deformation-induced hydrolysis of a degradable polymeric cylindrical annulus
Soares, J. S., Rajagopal, K. R., & Moore, J. E. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-009-0168-z · Cited by 76
Self-citationDeng, M., Zhou, J., Chen, G., Burkley, D., Xu, Y., Jamiolkowski, D., & Barbolt, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.067 · Cited by 75
Kang, Y., Yao, Y., Yin, G., Huang, Z., Liao, X., Xu, X., & Zhao, G. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.11.014 · Cited by 73
Expandable Bioresorbable Endovascular Stent. I. Fabrication and Properties
Su, S., Chao, R., Landau, C., Nelson, K. D., Timmons, R. B., Meidell, R. S., & Eberhart, R. C. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1575756 · Cited by 70
Thompson, D. E., Agrawal, C. M., & Athanasiou, K. (1996) · Tissue Engineering · doi:10.1089/ten.1996.2.61 · Cited by 59
Bünger, C. M., Grabow, N., Sternberg, K., Goosmann, M., Schmitz, K.-P., Kreutzer, H. J., Ince, H., Kische, S., Nienaber, C. A., Martin, D. P., et al. (2007) · Journal of Endovascular Therapy · doi:10.1177/152660280701400518 · Cited by 52
Effects of mechanical load on the degradation of poly(d,l-lactic acid) foam
Fan, Y., Li, P., Zeng, L., & Huang, X. (2008) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2007.12.015 · Cited by 49
Modeling of Deformation-Accelerated Breakdown of Polylactic Acid Biodegradable Stents
Soares, J. S., Moore, J. E., & Rajagopal, K. R. (2010) · Journal of Medical Devices · doi:10.1115/1.4002759 · Cited by 47
Self-citationGrabow, N., Bünger, C. M., Sternberg, K., Mews, S., Schmohl, K., & Schmitz, K. (2006) · Journal of Medical Devices · doi:10.1115/1.2355683 · Cited by 37
Degradation of Poly Lactide-based Biodegradable Materials
辻, 秀. (2008) · Nova Science Publishers eBooks · Cited by 36
Wu, Y., Shen, L., Wang, Q., Ge, L., Xie, J., Hu, X., Sun, A., Qian, J., & Ge, J. (2012) · BioMed Research International · doi:10.1155/2012/413956 · Cited by 34
Constitutive modeling for biodegradable polymers for application in endovascular stents
Soares, D. S., & Filipe, J. D. P. D. C. (2008) · Cited by 28
Influence of Mechanical Loads on Degradation of Scaffolds
Fan, Y., Li, P., & Yuan, X. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-14515-5_140 · Cited by 9
Drug-eluting stents and perioperative risk - more than matters of the heart?
Lanckohr, Torsello, Scheld, H., Schieffer, & Theilmeier (2012) · VASA · doi:10.1024/0301-1526/a000231 · Cited by 9
Influence of external stress on the in vitro degradation behavior of C3D/PLA composites
Wan, Y. Z., Wang, Y. L., Zheng, L., Zhou, F. G., Zhao, Q. Z., & Cheng, G. X. (2001) · Journal of Materials Science Letters · doi:10.1023/a:1013138919801 · Cited by 8
Tsuji (2000) · doi:10.1002/1097-4628(20000815)77:7
Perego (1998) · doi:10.1002/(sici)1097-4628(19960103)59:1<37::aid-app6>3.0.co;2-n
Cited by
Farah, S., Anderson, D. G., & Langer, R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.012 · Cited by 3,443
Lifetime prediction of biodegradable polymers
Laycock, B., Nikolić, M., Colwell, J. M., Gauthier, E., Halley, P., Bottle, S., & George, G. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.02.004 · Cited by 662
Bergström, J. S., & Hayman, D. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1455-8 · Cited by 266
Self-citationCardiovascular stents: overview, evolution, and next generation
Borhani, S., Hassanajili, S., Ahmadi Tafti, S. H., & Rabbani, S. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0097-y · Cited by 226
A Review of Material Degradation Modelling for the Analysis and Design of Bioabsorbable Stents
Boland, E. L., Shine, C. J., Kelly, N., Sweeney, C. A., & McHugh, P. E. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1413-5 · Cited by 108
Metadata
- Authors
- Hayman, D., Bergerson, C., Miller, S., Moreno, M., & Moore, J. E.
- Affiliations
- Imperial College London (GB)
- Texas A&M University (US)
- Corresponding author
- Moore, James E.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2014-06-03
- Volume
- 136
- Issue
- 8
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2095398921
- Cited by
- 48
- References
- 44
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 2 · 2021: 5 · 2020: 6 · 2019: 3 · 2018: 4 · 2017: 5 · 2016: 4 · 2015: 6
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Texas A and M University
- Royal Academy of Engineering
- Royal Society
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
- Keywords
- poly(L-lactic acid), biodegradable stents, polymer degradation, mechanical degradation, static loading, dynamic loading, fiber stiffness, strain energy function, degradation kinetics, shear modulus, in vivo degradation
- MeSH terms
- Models, Theoretical, Polyesters, Polymers, Stress, Mechanical, Stents, Weight-Bearing, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.