The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Identification of the biologically active liquid chemistry induced by a nonthermal atmospheric pressure plasma jet
Open accessAbstract
The mechanism of interaction of cold nonequilibrium plasma jets with mammalian cells in physiologic liquid is reported. The major biological active species produced by an argon RF plasma jet responsible for cell viability reduction are analyzed by experimental results obtained through physical, biological, and chemical diagnostics. This is complemented with chemical kinetics modeling of the plasma source to assess the dominant reactive gas phase species. Different plasma chemistries are obtained by changing the feed gas composition of the cold argon based RF plasma jet from argon, humidified argon (0.27%), to argon/oxygen (1%) and argon/air (1%) at constant power. A minimal consensus physiologic liquid was used, providing isotonic and isohydric conditions and nutrients but is devoid of scavengers or serum constituents. While argon and humidified argon plasma led to the creation of hydrogen peroxide dominated action on the mammalian cells, argon-oxygen and argon-air plasma created a very different biological action and was characterized by trace amounts of hydrogen peroxide only. In particular, for the argon-oxygen (1%), the authors observed a strong negative effect on mammalian cell proliferation and metabolism. This effect was distance dependent and showed a half life time of 30 min in a scavenger free physiologic buffer. Neither catalase and mannitol nor superoxide dismutase could rescue the cell proliferation rate. The strong distance dependency of the effect as well as the low water solubility rules out a major role for ozone and singlet oxygen but suggests a dominant role of atomic oxygen. Experimental results suggest that O reacts with chloride, yielding Cl2(-) or ClO(-). These chlorine species have a limited lifetime under physiologic conditions and therefore show a strong time dependent biological activity. The outcomes are compared with an argon MHz plasma jet (kinpen) to assess the differences between these (at least seemingly) similar plasma sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Normal keratinization in a spontaneously immortalized aneuploid human keratinocyte cell line.
Boukamp, P., Petrussevska, R. T., Breitkreutz, D., Hornung, J., Markham, A., & Fusenig, N. E. (1988) · The Journal of cell biology · doi:10.1083/jcb.106.3.761 · Cited by 4,170
Nordberg, J., & Arnér, E. S. J. (2001) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(01)00724-9 · Cited by 2,662
Graves, D. B. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/26/263001 · Cited by 1,518
Staehelin, J., & Hoigne, J. (1985) · Environmental Science & Technology · doi:10.1021/es00142a012 · Cited by 1,192
Lukes, P., Dolezalova, E., Sisrova, I., & Clupek, M. (2014) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/23/1/015019 · Cited by 1,181
Plasma surface modification of polymers for improved adhesion: a critical review
Liston, E. M., Martinu, L., & Wertheimer, M. R. (1993) · Journal of Adhesion Science and Technology · doi:10.1163/156856193x00600 · Cited by 1,091
On atmospheric-pressure non-equilibrium plasma jets and plasma bullets
Lu, X., Laroussi, M., & Puech, V (2012) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/21/3/034005 · Cited by 844
Low temperature atmospheric pressure plasma sources for microbial decontamination
Ehlbeck, J., Schnabel, U., Polak, M., Winter, J., von Woedtke, T., Brandenburg, R., von dem Hagen, T., & Weltmann, K.-D. (2011) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/44/1/013002 · Cited by 723
Self-citationInteractions of Peroxynitrite, Tetrahydrobiopterin, Ascorbic Acid, and Thiols
Kuzkaya, N., Weissmann, N., Harrison, D. G., & Dikalov, S. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m302227200 · Cited by 692
Hoigné, J., Bader, H., Haag, W. R., & Staehelin, J. (1985) · Water Research · doi:10.1016/0043-1354(85)90368-9 · Cited by 679
Samukawa, S., Hori, M., Rauf, S., Tachibana, K., Bruggeman, P., Kroesen, G., Whitehead, J. C., Murphy, A. B., Gutsol, A. F., Starikovskaia, S., et al. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/25/253001 · Cited by 657
Self-citationDenicola, A., Freeman, B. A., Trujillo, M., & Radi, R. (1996) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1996.0363 · Cited by 593
Ikawa, S., Kitano, K., & Hamaguchi, S. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900090 · Cited by 568
Wilkinson, F., & Brummer, J. G. (1981) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555655 · Cited by 564
Effects of Non-Thermal Plasma on Mammalian Cells
Kalghatgi, S., Kelly, C. M., Cerchar, E., Torabi, B., Alekseev, O., Fridman, A., Friedman, G., & Azizkhan-Clifford, J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016270 · Cited by 508
Rozema, J., Björn, L. O., Bornman, J. F., Gaberščik, A., Häder, D.-P., Trošt, T., Germ, M., Klisch, M., Gröniger, A., Sinha, R. P., et al. (2002) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/s1011-1344(01)00269-x · Cited by 428
Atmospheric Pressure Plasma Jet for Medical Therapy: Plasma Parameters and Risk Estimation
Weltmann, K. ‐., Kindel, E., Brandenburg, R., Meyer, C., Bussiahn, R., Wilke, C., & von Woedtke, T. (2009) · Contributions to Plasma Physics · doi:10.1002/ctpp.200910067 · Cited by 424
Self-citationKinetic modelling for an atmospheric pressure argon plasma jet in humid air
Gaens, W. V., & Bogaerts, A. (2013) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/46/27/275201 · Cited by 358
Self-citationULTRAVIOLET LIGHT INDUCED ALTERATION TO THE SKIN
Svobodova, A., Walterova, D., & Vostalova, J. (2006) · Biomedical Papers · doi:10.5507/bp.2006.003 · Cited by 358
van Gils, C. A. J., Hofmann, S., Boekema, B. K. H. L., Brandenburg, R., & Bruggeman, P. J. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/17/175203 · Cited by 346
Self-citationRate constants and mechanisms of reaction of chloride (Cl2-) radicals
Hasegawa, K., & Neta, P. (1978) · The Journal of Physical Chemistry · doi:10.1021/j100497a003 · Cited by 345
Hofmann, S., van Gessel, A. F. H., Verreycken, T., & Bruggeman, P. (2011) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/20/6/065010 · Cited by 304
Self-citationThe mechanism of catalase action. I. Steady-state analysis
Chance, B., Greenstein, D. S., & Roughton, F. J. W. (1952) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(52)90194-x · Cited by 285
Atmospheric pressure discharge filaments and microplasmas: physics, chemistry and diagnostics
Bruggeman, P., & Brandenburg, R. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/46/464001 · Cited by 283
Self-citationWinterbourn, C. C., Vissers, M. C., & Kettle, A. J. (2000) · Current Opinion in Hematology · doi:10.1097/00062752-200001000-00010 · Cited by 269
Pavlovich, M. J., Chang, H.-W., Sakiyama, Y., Clark, D. S., & Graves, D. B. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/14/145202 · Cited by 259
Clinical Plasma Medicine: State and Perspectives of in Vivo Application of Cold Atmospheric Plasma
von Woedtke, T., Metelmann, H. ‐., & Weltmann, K. ‐. (2014) · Contributions to Plasma Physics · doi:10.1002/ctpp.201310068 · Cited by 249
Self-citationFlash photolysis of transient radicals. 1. X2- with X = Cl, Br, I, and SCN
Nagarajan, V., & Fessenden, R. W. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100257a037 · Cited by 248
Modelling of microdischarge devices: plasma and gas dynamics
Kushner, M. J. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/11/001 · Cited by 243
Atomic oxygen formation in a radio-frequency driven micro-atmospheric pressure plasma jet
Waskoenig, J., Niemi, K., Knake, N., Graham, L. M., Reuter, S., Gathen, V. S.-V. D., & Gans, T. (2010) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/19/4/045018 · Cited by 240
Hydrogen peroxide: A central player in physical plasma-induced oxidative stress in human blood cells
Bekeschus, S., Kolata, J., Winterbourn, C., Kramer, A., Turner, R., Weltmann, K. D., Bröker, B., & Masur, K. (2014) · Free Radical Research · doi:10.3109/10715762.2014.892937 · Cited by 239
Self-citationWinter, J., Tresp, H., Hammer, M. U., Iseni, S., Kupsch, S., Schmidt-Bleker, A., Wende, K., Dünnbier, M., Masur, K., Weltmann, K.-D., et al. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/28/285401 · Cited by 227
Self-citationTresp, H., Hammer, M. U., Winter, J., Weltmann, K.-D., & Reuter, S. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/43/435401 · Cited by 209
Self-citationThe signal transducing photoreceptors of plants
Franklin, K. A., Larner, V. S., & Whitelam, G. C. (2005) · The International Journal of Developmental Biology · doi:10.1387/ijdb.051989kf · Cited by 202
From RONS to ROS: Tailoring Plasma Jet Treatment of Skin Cells
Reuter, S., Tresp, H., Wende, K., Hammer, M. U., Winter, J., Masur, K., Schmidt-Bleker, A., & Weltmann, K.-D. (2012) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2012.2207130 · Cited by 195
Self-citationSawa, T., Akaike, T., & Maeda, H. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m910169199 · Cited by 185
Wu, H., Sun, P., Feng, H., Zhou, H., Wang, R., Liang, Y., Lu, J., Zhu, W., Zhang, J., & Fang, J. (2012) · Plasma Processes and Polymers · doi:10.1002/ppap.201100065 · Cited by 182
Opinion on the use of plasma processes for treatment of foods*
Schlüter, O., Ehlbeck, J., Hertel, C., Habermeyer, M., Roth, A., Engel, K.-H., Holzhauser, T., Knorr, D., & Eisenbrand, G. (2013) · Molecular Nutrition & Food Research · doi:10.1002/mnfr.201300039 · Cited by 173
Thomas, E. L. (1979) · Infection and Immunity · doi:10.1128/iai.25.1.110-116.1979 · Cited by 169
Brisset, J.-L., & Hnatiuc, E. (2012) · Plasma Chemistry and Plasma Processing · doi:10.1007/s11090-012-9384-x · Cited by 162
Kinetic and mechanistic considerations to assess the biological fate of peroxynitrite
Carballal, S., Bartesaghi, S., & Radi, R. (2014) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2013.07.005 · Cited by 158
Perni, S., Shama, G., & Kong, M. G. (2008) · Journal of Food Protection · doi:10.4315/0362-028x-71.8.1619 · Cited by 142
Reuter, S., Winter, J., Schmidt-Bleker, A., et al. (2012) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/21/2/024005 · Cited by 125
Notice sur l'action de l'eau oxygénée sur les acides α‐cétoniques et sur les dicétones 1. 2
Holleman, A. F. (1904) · Recueil des Travaux Chimiques des Pays-Bas et de la Belgique · doi:10.1002/recl.19040230504 · Cited by 112
van Gessel, B., Brandenburg, R., & Bruggeman, P. (2013) · Applied Physics Letters · doi:10.1063/1.4817936 · Cited by 112
Self-citationWende, K., Straßenburg, S., Haertel, B., Harms, M., Holtz, S., Barton, A., Masur, K., von Woedtke, T., & Lindequist, U. (2013) · Cell Biology International · doi:10.1002/cbin.10200 · Cited by 93
Self-citationSchmidt, A., Wende, K., Bekeschus, S., Bundscherer, L., Barton, A., Jarick, K. J., Weltmann, K., & Masur, K. (2013) · Free Radical Research · doi:10.3109/10715762.2013.804623 · Cited by 88
Self-citationVasquez-Vivar, J. M., Denicola, A., Radí, R., & Augusto, O. (1997) · Chemical Research in Toxicology · doi:10.1021/tx970031g · Cited by 73
Redox-Based Assay for Assessment of Biological Impact of Plasma Treatment
Wende, K., Reuter, S., von Woedtke, T., Weltmann, K., & Masur, K. (2014) · Plasma Processes and Polymers · doi:10.1002/ppap.201300172 · Cited by 61
Self-citationPulse-radiolysis study of the reaction of nitric oxide with superoxide
Kobayashi, K., Miki, M., & Tagawa, S. (1995) · Journal of the Chemical Society Dalton Transactions · doi:10.1039/dt9950002885 · Cited by 52
Antimicrobial Synergy Between Ambient‐ G as Plasma and UVA Treatment of Aqueous Solution
Pavlovich, M. J., Sakiyama, Y., Clark, D. S., & Graves, D. B. (2013) · Plasma Processes and Polymers · doi:10.1002/ppap.201300065 · Cited by 25
Cited by
Plasma–liquid interactions: a review and roadmap
Bruggeman, P. J., Kushner, M. J., Locke, B. R., Gardeniers, J. G. E., Graham, W. G., Graves, D. B., Hofman-Caris, R. C. H. M., Maric, D., Reid, J. P., Ceriani, E., et al. (2016) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/25/5/053002 · Cited by 1,725
Self-citationLu, X., Naidis, G. V., Laroussi, M., Reuter, S., Graves, D. B., & Ostrikov, K. (2016) · Physics Reports · doi:10.1016/j.physrep.2016.03.003 · Cited by 1,230
Plasma-activated water: generation, origin of reactive species and biological applications
Zhou, R., Zhou, R., Wang, P., Xian, Y., Mai-Prochnow, A., Lu, X., Cullen, P. J., Ostrikov, K. (., & Bazaka, K. (2020) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ab81cf · Cited by 714
Reuter, S., von Woedtke, T., & Weltmann, K.-D. (2018) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aab3ad · Cited by 522
Self-citationThe plasma jet kINPen – A powerful tool for wound healing
Bekeschus, S., Schmidt, A., Weltmann, K.-D., & von Woedtke, T. (2016) · Clinical Plasma Medicine · doi:10.1016/j.cpme.2016.01.001 · Cited by 390
Self-citation
Metadata
- Authors
- Wende, K., Williams, P., Dalluge, J., Van Gaens, W., Aboubakr, H., Bischof, J., von Woedtke, T., Goyal, S. M., Weltmann, K.-D., Bogaerts, A., Masur, K., & Bruggeman, P. J.
- Venue
- Biointerphases
- Publisher
- American Vacuum Society
- Published
- 2015-06
- Volume
- 10
- Issue
- 2
- Pages
- 029518
- ISSN
- 1559-4106 (ISSN-L)
- 1934-8630
- OpenAlex
- W1583028397
- Cited by
- 279
- References
- 51
- FWCI
- 25.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.