Real-time Raman system for in vivo disease diagnosis
Open accessThe DOI matches its Crossref record.
Abstract
Raman spectroscopy has been well established as a powerful in vitro method for studying biological tissue and diagnosing disease. The recent development of efficient, high-throughput, low-background optical fiber Raman probes provides, for the first time, the opportunity to obtain real-time performance in the clinic. We present an instrument for in vivo tissue analysis which is capable of collecting and processing Raman spectra in less than 2 s. This is the first demonstration that data acquisition, analysis, and diagnostics can be performed in clinically relevant times. The instrument is designed to work with the new Raman probes and includes custom written LabVIEW and Matlab programs to provide accurate spectral calibration, analysis, and diagnosis along with important safety features related to laser exposure. The real-time capabilities of the system were demonstrated in vivo during femoral bypass and breast lumpectomy surgeries. Such a system will greatly facilitate the adoption of Raman spectroscopy into clinical research and practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Noninvasive molecular imaging of small living subjects using Raman spectroscopy
Keren, S., Zavaleta, C., Cheng, Z., de la Zerda, A., Gheysens, O., & Gambhir, S. S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710575105 · Cited by 604
Chemically sensitive bioimaging with coherent Raman scattering
Camp Jr, C. H., & Cicerone, M. T. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.60 · Cited by 472
In vivo Margin Assessment during Partial Mastectomy Breast Surgery Using Raman Spectroscopy
Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Lyons, J., Hicks, D., Fitzmaurice, M., Dasari, R. R., Crowe, J. P., & Feld, M. S. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-2815 · Cited by 424
Self-citationClinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Vibrational spectroscopy: a clinical tool for cancer diagnostics
Kendall, C., Isabelle, M., Bazant-Hegemark, F., Hutchings, J., Orr, L., Babrah, J., Baker, R., & Stone, N. (2009) · The Analyst · doi:10.1039/b822130h · Cited by 293
Raman and CARS microspectroscopy of cells and tissues
Krafft, C., Dietzek, B., & Popp, J. (2009) · The Analyst · doi:10.1039/b822354h · Cited by 271
Raman Imaging in Biochemical and Biomedical Applications. Diagnosis and Treatment of Breast Cancer
Abramczyk, H., & Brozek-Pluska, B. (2013) · Chemical Reviews · doi:10.1021/cr300147r · Cited by 252
In-vivo Raman spectroscopy: from basics to applications
Cordero, E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.7.071210 · Cited by 195
“Another clinical setup was introduced byMotz et al.,49 which uses a sapphire ball lens with a 2-mm diameter and a coupled fiber probe with 15 collection fibers.50 Here, filters deposited on a special glass substrate were used, instead of directly coating the fiber ends.43 The probe was applied for margin assessment du…”
BackgroundInfluentialGajjar, K., Heppenstall, L. D., Pang, W., Ashton, K. M., Trevisan, J., Patel, I. I., Llabjani, V., Stringfellow, H. F., Martin-Hirsch, P. L., Dawson, T., et al. (2013) · Anal. Methods · doi:10.1039/c2ay25544h · Cited by 172
Raman imaging at biological interfaces: applications in breast cancer diagnosis
Surmacki, J., Musial, J., Kordek, R., & Abramczyk, H. (2013) · Molecular Cancer · doi:10.1186/1476-4598-12-48 · Cited by 143
“Optical Raman imaging has emerged as a new modality which enables real time, non-invasive, high resolution imaging of epithelial tissue, with a particular focus in this paper on breast cancer diagnosis [15-34].”
BackgroundCordero, E., Korinth, F., Stiebing, C., Krafft, C., Schie, I., & Popp, J. (2017) · Sensors · doi:10.3390/s17081724 · Cited by 58
Metadata
- Authors
- Motz, J. T., Gandhi, S. J., Scepanovic, O. R., Haka, A. S., Kramer, J. R., Dasari, R. R., & Feld, M. S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2005
- Volume
- 10
- Issue
- 3
- Pages
- 031113
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2014959995
- Cited by
- 139
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.