The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic tomography
Open accessAbstract
Simultaneous transcranial imaging of two functional parameters, the total concentration of hemoglobin and the hemoglobin oxygen saturation, in the rat brain in vivo is realized noninvasively using laser-based photoacoustic tomography (PAT). As in optical diffusion spectroscopy, PAT can assess the optical absorption of endogenous chromophores, e.g., oxygenated and deoxygenated hemoglobins, at multiple optical wavelengths. However, PAT can provide high spatial resolution because its resolution is diffraction-limited by photoacoustic signals rather than by optical diffusion. Laser pulses at two wavelengths are used sequentially to acquire photoacoustic images of the vasculature in the cerebral cortex of a rat brain through the intact skin and skull. The distributions of blood volume and blood oxygenation in the cerebral cortical venous vessels, altered by systemic physiological modulations including hyperoxia, normoxia, and hypoxia, are visualized successfully with satisfactory spatial resolution. This technique, with its prominent sensitivity to endogenous contrast, can potentially contribute to the understanding of the interrelationship between neural, hemodynamic, and metabolic activities in the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827 · cited 1×
“The phenomena observed in this study agree with the well-established physiology of the brain.(31,32)”
ResultWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Self-citationNon-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Photoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572
Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
Xu, M., & Wang, L. V. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801176 · Cited by 461
Self-citationThree-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Dunn, A. K., Devor, A., Bolay, H., Andermann, M. L., Moskowitz, M. A., Dale, A. M., & Boas, D. A. (2003) · Optics Letters · doi:10.1364/ol.28.000028 · Cited by 333
Millikan, G. A. (1942) · Review of Scientific Instruments · doi:10.1063/1.1769941 · Cited by 331
Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors
Esenaliev, R. O., Karabutov, A. A., & Oraevsky, A. A. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796320 · Cited by 239
Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study
Esenaliev, R. O., Larina, I. V., Larin, K. V., Deyo, D. J., Motamedi, M., & Prough, D. S. (2002) · Applied Optics · doi:10.1364/ao.41.004722 · Cited by 203
Thermoacoustic Molecular Imaging of Small Animals
Kruger, R. A., Kiser, W. L., Reinecke, D. R., Kruger, G. A., & Miller, K. D. (2003) · Molecular Imaging · doi:10.1162/15353500200303109 · Cited by 187
Measurements of scattering and absorption changes in muscle and brain
Gratton, E., Fantini, S., Franceschini, M. A., Gratton, G., & Fabiani, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0055 · Cited by 182
Determination of optical properties and blood oxygenation in tissue using continuous NIR light
Liu, H., Boas, D. A., Zhang, Y., Yodh, A. G., & Chance, B. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/11/015 · Cited by 167
Detection of ultrawide-band ultrasound pulses in optoacoustic tomography
Андреев, В. Г., Karabutov, A. A., & Oraevsky, A. A. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1244756 · Cited by 131
Kruger, R. A. (1994) · Medical Physics · doi:10.1118/1.597367 · Cited by 130
Optical and Nuclear Magnetic Resonance Studies of Hypoxia in Human Tissue and Tumors a
Chance, B., Borer, E. T., EVANS, A., Holtom, G., Kent, J. A., Maris, M. B., McCully, K. K., Northrop, J. K., & Shinkwin, M. A. (1988) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1988.tb22316.x · Cited by 36
Barbour, R. L., Gebrewold, A., & Altura, B. M. (1993) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.1993.tb05248.x · Cited by 31
Cited by
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Carbon nanotubes as photoacoustic molecular imaging agents in living mice
De La Zerda, A., Zavaleta, C., Keren, S., Vaithilingam, S., Bodapati, S., Liu, Z., Levi, J., Smith, B. R., Ma, T.-J., Oralkan, O., et al. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.231 · Cited by 1,271
Kim, C., Favazza, C., & Wang, L. V. (2010) · Chemical Reviews · doi:10.1021/cr900266s · Cited by 807
Self-citationQuantitative spectroscopic photoacoustic imaging: a review
Cox, B., Laufer, J. G., Arridge, S. R., & Beard, P. C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061202 · Cited by 720
Photoacoustic tomography and sensing in biomedicine
Li, C., & Wang, L. V. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/r01 · Cited by 669
Self-citation
Metadata
- Authors
- Wang, X., Xie, X., Ku, G., Wang, L. V., & Stoica, G.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2006
- Volume
- 11
- Issue
- 2
- Pages
- 024015
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2171221778
- Cited by
- 505
- References
- 18
- FWCI
- 14.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.