Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans
Open accessThe DOI matches its Crossref record; 123 of the 230 references it cites were found in a registry or an index, and 106 are not checked yet.
Abstract
Near-infrared spectroscopy (NIRS) was initiated in 1977 by Jobsis as a simple, noninvasive method for measuring the presence of oxygen in muscle and other tissues in vivo. This review honoring Jobsis highlights the progress that has been made in developing and adapting NIRS and NIR imaging (NIRI) technologies for evaluating skeletal muscle O2 dynamics and oxidative energy metabolism. Development of NIRS/NIRI technologies has included novel approaches to quantification of the signal, as well as the addition of multiple source detector pairs for imaging. Adaptation of NIRS technology has focused on the validity and reliability of NIRS measurements. NIRS measurements have been extended to resting, ischemic, localized exercise, and whole body exercise conditions. In addition, NIRS technology has been applied to the study of a number of chronic health conditions, including patients with chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, varying muscle diseases, spinal cord injury, and renal failure. As NIRS technology continues to evolve, the study of skeletal muscle function with NIRS first illuminated by Jobsis continues to be bright.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When debating a specific gold standard to which NIRS-derived SmO2 should be compared, an obvious lack of authority exists as the term is not mentioned in reviews,6,20,21 with appropriate hesitation.”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [20]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationOwen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Self-citationDuncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Mancini, D. M., Katz, S. D., Lang, C. C., LaManca, J., Hudaihed, A., & Androne, A.-S. (2003) · Circulation · doi:10.1161/01.cir.0000044914.42696.6a · Cited by 542
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 3×
“light source to the detector is that it follows a banana-shaped curve, in which the penetration depth into the tissue is approximately equal to half the distance between the light source and the detector.(23) If light source-detector separation”
BackgroundMethodSelf-citationAbnormal Cardiac and Skeletal Muscle Energy Metabolism in Patients With Type 2 Diabetes
Scheuermann-Freestone, M., Madsen, P. L., Manners, D., Blamire, A. M., Buckingham, R. E., Styles, P., Radda, G. K., Neubauer, S., & Clarke, K. (2003) · Circulation · doi:10.1161/01.cir.0000072789.89096.10 · Cited by 525
Research works printed but not linked: 10
- V. Quaresima, R. Lepanto, and M. Ferrari, "The use of near infrared spectroscopy in sports medicine," J. Sports Med. Phys. Fitness 43, 1-13 ͑2003͒.
- K. K. McCully and T. Hamaoka, "Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle?," Exerc Sport Sci. Rev. 28, 123-127 ͑2000͒.
- M. Niwayama, K. Yamamoto, D. Kohata, K. Hirai, N. Kudo, T. Hamaoka, R. Kime, and T. Katsumura, "A 200-channel imaging sys- tem of muscle oxygenation using CW near-infrared spectroscopy," IEICE Trans. Inf. Syst. E85-D, 115-123 ͑2002͒.
- B. Chance, D. J. Wang, S. Nioka, Z. Wang, E. A. Noyszewski, T. Hamaoka, and J. S. Leigh, Jr., "Myoglobin and hemoglobin deoxy- genation during muscle exercise in dogs," Specialty Conf. Am. Col- lege Sports Med. Regulation Oxidative Metab. Blood Flow Skele. Muscle abstract, p. 20 ͑1995͒.
- O. Piazza, G. Zito, A. Valente, and R. Tufano, "Effects of dopamine infusion on forearm blood flow in critical patients," Med. Sci. Monit 12, CR90-93 ͑2006͒.
- Buono, 2005, Eur. J. Vasc. Surg., 55, 241
- Komiyama, 1996, Int. Angiol, 15, 215
- Belardinelli, 1995, G. Ital. Cardiol., 25, 715
- Tateishi, 2005, Osaka City Med. J., 51, 65
- 10.1002/(sici)1097-4598(199710)20:10<1242::aid-mus6>3.0.co;2-c · doi:10.1002/(sici)1097-4598(199710)20:10<1242::aid-mus6>3.0.co;2-c
Cited by
Items 301–400 of 652
Nirengi, S., Sakane, N., Amagasa, S., Wakui, S., Homma, T., Kurosawa, Y., & Hamaoka, T. (2018) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.1186/s40101-018-0166-x · Cited by 15
“The distance between the emitter and detector was set at 30 mm [23].”
BackgroundSelf-citationMuscle force recovery in relation to muscle oxygenation
Ufland, P., Lapole, T., Ahmaidi, S., & Buchheit, M. (2012) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2012.01141.x · Cited by 15
“However, this method is generally reported to be painful for the participants, because complete muscle desaturation requires a prolonged occlusion (i.e. up to 12 min (Hamaoka et al., 2007)).”
MethodHomma, T., Hamaoka, T., Sako, T., Murakami, M., Esaki, K., Kime, R., & Katsumura, T. (2005) · Dynamic Medicine · doi:10.1186/1476-5918-4-2 · Cited by 16
Self-citationDiagnosis of testicular torsion using near infrared spectroscopy: A novel diagnostic approach
Shadgan, B., Fareghi, M., Stothers, L. S., Macnab, A. J., & Kajbafzadeh, A. M. (2014) · Canadian Urological Association Journal · doi:10.5489/cuaj.1672 · Cited by 14
Yamaki, T., Konoeda, H., Osada, A., Hamahata, A., Kono, T., Soejima, K., Nozaki, M., & Sakurai, H. (2013) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2013.05.002 · Cited by 14
Hasnan, N., Saadon, N. S. M., Hamzaid, N. A., Teoh, M., Ahmadi, S., & Davis, G. M. (2018) · Medicine · doi:10.1097/md.0000000000012922 · Cited by 14
“5 popular for estimation of relative changes in muscle tissue oxygenation.([13,20]) Neurophysiological control of muscle blood flow, muscle oxygen uptake, and tissue oxygen saturation during exercise are titrated by descending adrenergic sympathetic vasoconstrictor stimulation and intrinsic vasodilator control, and th…”
BackgroundMethodChuang, M., Lin, I., & Hsieh, M. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8101641 · Cited by 15
Chen, Y.-H., Huang, C.-C., Lin, H., Cheng, S.-Y., & Wu, H.-P. (2021) · Journal of the Formosan Medical Association · doi:10.1016/j.jfma.2021.05.018 · Cited by 14
Paulauskas, R., Nekriošius, R., Dadelienė, R., Sousa, A., & Figueira, B. (2022) · Sensors · doi:10.3390/s22218238 · Cited by 16
“Thus, NIRS technology can supply information on SmO2 and the tHb index in real time [4,5].”
BackgroundInfluentialAldayel, A. A., Muthalib, M., Jubeau, M., McGuigan, M. R., & Nosaka, K. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1699-9 · Cited by 15
“The dynamic balance between O2 demand and O2 supply is reflected in the changes in DTOI, and the changes are affected by O2 extraction and blood flow/volume (Hamaoka et al. 2007).”
BackgroundMacnab, A. J., Friedman, B., Shadgan, B., & Stothers, L. S. (2012) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-2012-0020 · Cited by 15
Crosstalk and error analysis of fat layer on continuous wave near-infrared spectroscopy measurements
Şayli, Ö., Aksel, E. B., & Akın, A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3028008 · Cited by 14
Moalla, W., Dupont, G., Temfemo, A., Maingourd, Y., Weston, M., & Ahmaïdi, S. (2008) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-196 · Cited by 19
Yamazaki, K., Suzuki, K., Itoh, H., Muramatsu, K., Nagahashi, K., Tamura, N., Uchida, T., Sugihara, K., Maeda, H., & Kanayama, N. (2012) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12001 · Cited by 14
Reproducibility of Measurement of Muscle Deoxygenation in Children During Exercise
Leclair, E., Thévenet, D., Reguem, S. C., Borel, B., Baquet, G., Berthoin, S., & Mucci, P. (2010) · Pediatric Exercise Science · doi:10.1123/pes.22.2.183 · Cited by 15
Muscle oxygenation monitoring using near-infrared spectroscopy
Hamaoka, T. (2013) · The Journal of Physical Fitness and Sports Medicine · doi:10.7600/jpfsm.2.203 · Cited by 16
Self-citationRecruitment of the Serratus Anterior as an Accessory Muscle of Ventilation during Graded Exercise
Cannon, D. T., Grout, S. L., May, C. A., Strom, S. D., Wyckoff, K. G., Cipriani, D. J., & Buono, M. J. (2007) · The Journal of Physiological Sciences · doi:10.2170/physiolsci.rp001807 · Cited by 17
Localised muscle tissue oxygenation during dynamic exercise with whole body vibration.
Robbins, D., Elwell, C. E., Jiménez, A., & Goss-Sampson, M. A. (2012) · Europe PMC (PubMed Central) · Cited by 17
Porter, M. S., & Langley, J. O. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.12242 · Cited by 13
“…correlation between SmO 2 desaturation and the time dependent changes in PCr work, in agreement with previous research (Dunst et al., 2023; Hamaoka et al., 2007; Jones et al., 2008 During all - out exercise, the PCr energy supply has been shown to plateau after 10–15 s with little to no…”
Richard, P., & Billaut, F. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01036 · Cited by 18
Morishima, T., Tsuchiya, Y., Ueda, H., & Ochi, E. (2020) · Physiological Reports · doi:10.14814/phy2.14546 · Cited by 13
Vasquez-Bonilla, A. A., Tomás-Carús, P., Brazo‐Sayavera, J., Malta, J., Folgado, H., & Olcina, G. J. (2023) · Science & Sports · doi:10.1016/j.scispo.2022.03.014 · Cited by 13
Wang, C., Chuang, M., Liang, S., Tsai, J.-C., Chuang, C., Hsieh, Y., Lu, C.-W., Lee, P., & Sun, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2147315 · Cited by 14
Intestinal perfusion monitoring using photoplethysmography
Akl, T. J., Wilson, M. A., Ericson, M. N., & Coté, G. L. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.8.087005 · Cited by 14
“Near-infrared spectroscopy (NIRS) is perhaps the most common of these techniques.(7,19,20) The technique delivers multiple NIR wavelengths of light to the tissue, and the diffusely reflected light is collected and analyzed.”
BackgroundNear-infrared spectroscopy for evaluation of global and skeletal muscle tissue oxygenation
Možina, H., & Podbegar, M. (2011) · World Journal of Cardiology · doi:10.4330/wjc.v3.i12.377 · Cited by 13
Near‐infrared spectroscopy during exercise and recovery in children with juvenile dermatomyositis
Habers, G. E. A., de Knikker, R., van Brussel, M., Hulzebos, E. H. J., Stegeman, D. F., van Royen‐Kerkhof, A., & Takken, T. (2012) · Muscle & Nerve · doi:10.1002/mus.23484 · Cited by 13
“22 %VATpeak kg 1 (%), median (IQR) 37 (19) H†,JIA† 58 (14) 60 (17) v(2)(2) 1⁄4 10.”
Kao, W.-L., & Sun, C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0135166 · Cited by 13
“To avoid the use of an exogenous tracer, one study [6] proposed analyzing the abrupt changes of oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) after vessel occlusion.”
MethodHoriuchi, M., & Fukuoka, Y. (2019) · Spinal Cord · doi:10.1038/s41393-019-0301-5 · Cited by 13
Guimarães, G. V., Ribeiro, F., Castro, R. E., Roque, J. M., Machado, A. D. T., Antunes‐Correa, L. M., Ayub‐Ferreira, S. M., & Bocchi, E. A. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.08.050 · Cited by 13
Buzza, G., Lovell, G. P., Askew, C. D., Kerhervé, H. A., & Solomon, C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165433 · Cited by 15
Rębiś, K., Sadowska, D., Starczewski, M., & Klusiewicz, A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.809864 · Cited by 12
Lee, S. M. C., Clarke, M. S. F., O’Connor, D. P., Stroud, L., Ellerby, G. E. C., & Soller, B. R. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1797-8 · Cited by 12
“Interpreting SO2 and HbT responses during exercise would be enhanced through the specific measurement of local metabolic rate, but NIRS by itself does not measure muscle VO2 ( Hamaoka et al. 2007 ).”
BackgroundStuer, L., Teso, M., Colosio, A. L., Loi, M., Mucci, P., Pogliaghi, S., Boone, J., & Caen, K. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05654-5 · Cited by 13
Acosta, F. M., Berchem, J., Martínez‐Téllez, B., Sánchez‐Delgado, G., Alcántara, J. M. A., Ortiz-Alvarez, L., Hamaoka, T., & Ruiz, J. R. (2018) · Molecular Imaging and Biology · doi:10.1007/s11307-018-1244-5 · Cited by 14
Self-citationNell, H. J., Castelli, L. M., Bertani, D., Jipson, A. A., Meagher, S. F., Melo, L. T. M., Zabjek, K., & Reid, W. D. (2020) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-020-00163-2 · Cited by 15
IPC recovery length of 45 minutes improves muscle oxygen saturation during active sprint recovery
Seeley, A. D., & Jacobs, K. A. (2021) · European Journal of Sport Science · doi:10.1080/17461391.2021.1939429 · Cited by 12
Szucs, B., Petrekanits, M., Fekete, M., & Varga, J. T. (2021) · Physiology International · doi:10.1556/2060.2021.00185 · Cited by 12
Maliszewski, K., Feldmann, A., McCully, K. K., & Julian, R. (2024) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-024-00809-5 · Cited by 13
“Near-infrared spectroscopy (NIRS) can be used in vivo as a non-invasive and simple assessment to measure the oxygen consumption rate in skeletal muscle [5–7].”
MethodSelf-citationEffect of pedal cadence on the heterogeneity of muscle deoxygenation during moderate exercise
Zorgati, H., Collomp, K., Amiot, V., & Prieur, F. (2013) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2012-0504 · Cited by 16
Mehta, J. P., Lavender, S. A., Jagacinski, R. J., & Sommerich, C. M. (2014) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720814551556 · Cited by 12
Relationship between muscle oxygenation by NIRS and blood lactate
Xu, G., Mao, Z., Ye, Y., & Lv, K. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/277/1/012042 · Cited by 14
McGorry, R. W., Maikala, R. V., Lin, J., & Rivard, A. J. (2008) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2008.10.014 · Cited by 14
Finnerty, N. J., & Bolger, F. B. (2017) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2017.09.010 · Cited by 12
Gepner, Y., Gordon, J. A., Hoffman, J. R., Stout, J. R., Fukuda, D. H., Coker, N. A., Varanoske, A. N., Arroyo, E., & Wells, A. J. (2019) · Kinesiology · doi:10.26582/k.51.1.4 · Cited by 13
Eiken, F. L., Pedersen, B. L., Bækgaard, N., & Eiberg, J. (2019) · International Angiology · doi:10.23736/s0392-9590.18.04051-8 · Cited by 12
Shadgan, B., Stothers, L. S., & Macnab, A. J. (2008) · Spectroscopy An International Journal · doi:10.1155/2008/548152 · Cited by 15
Takei, N., Soo, J., Hatta, H., & Girard, O. (2021) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2020-0654 · Cited by 11
Nakajima, M., Tsuro, T., & Endo, A. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19031692 · Cited by 11
Oscillation of oxygenation in skeletal muscle at rest and in light exercise
Yano, T., Lian, C., Arimitsu, T., Yamanaka, R., Afroundeh, R., Shirakawa, K., & Yunoki, T. (2013) · Acta Physiologica Hungarica · doi:10.1556/aphysiol.100.2013.007 · Cited by 13
Osawa, T., Arimitsu, T., & Takahashi, H. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3696-8 · Cited by 12
“The balance between tissue oxygen delivery and consumption determines tissue oxygenation, which mainly reflects the microcirculation (Hamaoka et al. 2007).”
Portable muscle oxygenation monitor based on near infrared spectroscopy
Zhang, Z., Wang, B., Qing, N., Luo, Q., & Gong, H. (2009) · Frontiers of Optoelectronics in China · doi:10.1007/s12200-009-0050-8 · Cited by 12
“The generation of lactate is affected by the concentration changes of the oxygen carriers, HbO 2 and Hb, in the skeletal muscles [11].”
InfluentialDoes voluntary hypoventilation during exercise impact EMG activity?
Kume, D., Akahoshi, S., Yamagata, T., Wakimoto, T., & Nagao, N. (2016) · SpringerPlus · doi:10.1186/s40064-016-1845-x · Cited by 12
Hybrid sEMG, NIRS and MMG Sensor System
Ding, X., Wang, M., Guo, W., Sheng, X., & Zhu, X. (2018) · International Conference on Mechatronics and Machine Vision in Practice (M2VIP) · doi:10.1109/m2vip.2018.8600866 · Cited by 11
Intelligent Systems for Muscle Tracking: A Review on Sensor‐Algorithm Synergy
Putcha, A., Nguyen, T., Smith, R., Choffin, R., & Bai, W. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200351 · Cited by 10
Wu, Y., Song, T., & Xu, G. (2015) · Frontiers of Optoelectronics · doi:10.1007/s12200-015-0532-9 · Cited by 11
Effects of multicomponent exercise training on muscle oxygenation in young and older adults
Lin, T.-Y., Chen, J. J., Lin, L. L.-C., Yang, W.-T. O., Chen, M., & Tsai, Y.-C. (2022) · Journal of Exercise Science & Fitness · doi:10.1016/j.jesf.2022.12.002 · Cited by 11
Desanlis, J., Gordon, D. A., French, C., Calveyrac, C., Cottin, F., & Gernigon, M. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1441239 · Cited by 11
Palzkill, V. R., Tan, J., Moparthy, D., Tice, A. L., Ferreira, L. F., & RYAN, T. E. (2024) · JACC Basic to Translational Science · doi:10.1016/j.jacbts.2024.08.011 · Cited by 10
Kuroiwa, M., Fuse, S., Amagasa, S., Kime, R., Endo, T., Kurosawa, Y., & Hamaoka, T. (2019) · Applied Sciences · doi:10.3390/app9122442 · Cited by 10
“Then, the absolute (total-Hb) was calculated as the sum of (oxy-Hb) and (deoxy-Hb) [5,12] from the following calculation formula.”
BackgroundMethodSelf-citationSkeletal Muscle Microvascular Adaptations Following Regular Cold Water Immersion
Ihsan, M., Watson, G., Choo, H. C., Govus, A. D., Cocking, S., Stanley, J., & Abbiss, C. R. (2019) · International Journal of Sports Medicine · doi:10.1055/a-1044-2397 · Cited by 11
Wakasugi, T., Morishita, S., Kaida, K., Ikegame, K., Uchiyama, Y., & Domen, K. (2021) · Supportive Care in Cancer · doi:10.1007/s00520-021-06178-w · Cited by 12
Julian, V., Thivel, D., Pereira, B., Costes, F., Richard, R., & Duclos, M. (2016) · Obesity Facts · doi:10.1159/000447456 · Cited by 10
Oueslati, F., Boone, J., Tabka, Z., & Ahmaidi, S. (2017) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2017.01.012 · Cited by 13
Zhang, C., Hodges, B., & McCully, K. K. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab921c · Cited by 10
“However, the apparent limitations of this technique, such as the high cost, high technical requirement, large size and limited availability (Hamaoka et al 2007), prevent MRS from being widely used.”
BackgroundSelf-citationApplegate, M. B., Amelard, R., Gómez, C. A., & Roblyer, D. M. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3072036 · Cited by 10
Nirengi, S., Fuse, S., Amagasa, S., Homma, T., Kime, R., Kuroiwa, M., Endo, T., Sakane, N., Matsushita, M., Saito, M., et al. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20092214 · Cited by 9
“Hence, many studies have been reported in which results are presented as oxy-Hb/oxy-Mb, deoxy-Hb/deoxy-Mb, and total-Hb/total-Mb concentrations [17].”
BackgroundMethodSelf-citationHyperoxia Improves Repeated-Sprint Ability and the Associated Training Load in Athletes
Cyr-Kirk, S., & Billaut, F. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.817280 · Cited by 11
McGranahan, M. J., Kibildis, S. W., McCully, K. K., & O’Connor, P. J. (2023) · Microvascular Research · doi:10.1016/j.mvr.2023.104532 · Cited by 9
Self-citationIzumi, K., Yamamori, K., Katayama, K., Kano, Y., Tanaka, N., & Akima, H. (2024) · Experimental Physiology · doi:10.1113/ep091948 · Cited by 9
Poyton, R. Ο., & Hendrickson, M. (2016) · Cited by 9
Ghatas, M. P., Holman, M. E., & Gorgey, A. S. (2019) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2019.1631585 · Cited by 9
Goto, M., Nirengi, S., Kurosawa, Y., Nagano, A., & Hamaoka, T. (2016) · Europe PMC (PubMed Central) · Cited by 19
Self-citationIshii, K., Matsukawa, K., Asahara, R., Liang, N., Endo, K., Idesako, M., Michioka, K., Sasaki, Y., Hamada, H., Yamashita, K., et al. (2017) · Physiological Reports · doi:10.14814/phy2.13237 · Cited by 9
Freitag, N., Böttrich, T., Weber, P. D., Manferdelli, G., Bizjak, D. A., Grau, M., Sanders, T. C., Bloch, W., & Schumann, M. (2020) · Sports · doi:10.3390/sports8010004 · Cited by 9
The Case for Measuring Long Bone Hemodynamics With Near-Infrared Spectroscopy
Zhang, C., & McCully, K. K. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.615977 · Cited by 9
Self-citationYano, T., Lian, C.-S., Afroundeh, R., Shirakawa, K., & Yunoki, T. (2013) · Biology of Sport · doi:10.5604/20831862.1083274 · Cited by 9
Mizuno, M., Tokizawa, K., & Muraoka, I. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0110-8 · Cited by 9
Kinetics of Oxygenation in Inactive Forearm Muscle during Ramp Leg Cycling
Ogata, H., Reyihan, A., & Yano, T. (2004) · Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science · doi:10.2114/jpa.23.7 · Cited by 12
Active and Inactive Leg Hemodynamics during Sequential Single-Leg Interval Cycling
Gordon, N. A., Abbiss, C. R., Ihsan, M., Maiorana, A., & Peiffer, J. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001553 · Cited by 10
Blasi, R. A. D. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1146-0 · Cited by 9
“The continuing technological advances have also led to NIRS studies designed to obtain optical images of blood perfusion and tissue metabolism [ 3 , 18].”
BackgroundMuscle oxygenation in response to high intensity interval exercises among high trained judokas
Kujach, S., Ziemann, E., Grzywacz, T., Łuszczyk, M., Smaruj, M., Dzedzej, A., & Laskowski, R. (2016) · Isokinetics and Exercise Science · doi:10.3233/ies-160631 · Cited by 9
“TOI reflects the dynamic balance of O 2 supply by the muscle microcirculation and O 2 consumption/demand by the muscle [18] and the changes in tHb can be considered an indirect measure of changes in local muscle blood flow/O 2 supply [15].”
Delayed Onset of Reoxygenation in Inactive Muscles After High-Intensity Exercise
Osawa, T., Shiose, K., & Takahashi, H. (2017) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-55231-6_35 · Cited by 8
Endo, T., Kime, R., Fuse, S., Murase, N., Kurosawa, Y., & Hamaoka, T. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002530 · Cited by 8
Self-citationZhang, C., Modlesky, C. M., & McCully, K. K. (2021) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2021-0135 · Cited by 8
Self-citationDenis, R., Wilkinson, J., & VITO, G. D. (2011) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2011.01023.x · Cited by 8
Discrepancy between femoral and capillary blood flow kinetics during knee extension exercise
Schlup, S. J., Ade, C. J., Broxterman, R. M., & Barstow, T. J. (2015) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2015.08.005 · Cited by 9
Ishii, K., Matsukawa, K., Liang, N., Endo, K., Idesako, M., Hamada, H., Kataoka, T., Ueno, K., Watanabe, T., & Takahashi, M. K. (2014) · Physiological Reports · doi:10.14814/phy2.12202 · Cited by 8
Weng, W., Chen, J.-C., Lee, C., Lin, C.-W., Lee, W., Shieh, J., Wang, C., & Chuang, C. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.004767 · Cited by 8
Measures of localized spinal muscle fatigue
Kumar, S., Fagarasanu, M., Narayan, Y., & Prasad, N. (2006) · Ergonomics · doi:10.1080/00140130500435595 · Cited by 8
Yano, T., Horiuchi, M., Yunoki, T., Matsuura, R., & Ogata, H. (2005) · Physiological Research · doi:10.33549/physiolres.930731 · Cited by 11
Adults with initial metabolic syndrome have altered muscle deoxygenation during incremental exercise
Machado, A. C., Barbosa, T. C., Sales, A. R. K., de Souza, M. N., da Nóbrega, A. C. L., & Silva, B. M. (2017) · Obesity · doi:10.1002/oby.21744 · Cited by 8
Eroğlu, M. N., Köse, B., Kolayiş, İ. E., & Haberal, B. (2026) · Scientific Reports · doi:10.1038/s41598-026-37514-x · Cited by 7
Liau, B.-Y., Lung, C.-W., Hernandez, M. E., Mo, P., Li, Y., Guo, J., & Jan, Y. (2023) · Biomedical Optics Express · doi:10.1364/boe.493897 · Cited by 7
Tujjar, O., Gaudio, A. R. D., Tofani, L., & Filippo, A. D. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9877-x · Cited by 8
“NIRS technology is described in detail elsewhere [10, 11].”
MethodHemodynamics Study Based on Near-Infrared Optical Assessment
Sun, C., & Chuang, C. (2012) · InTech eBooks · doi:10.5772/38229 · Cited by 10
Correlation between tissue oxygenation and erythrocytes elasticity
Wu, Y., Chiou, A., & Sun, C. (2010) · Journal of Biophotonics · doi:10.1002/jbio.201000082 · Cited by 8
da Silva, J. A., Souza, D. Ú. F., Ferreira, D. R., Valeriano, M. C. P., dos Santos, R. F., Britto, R. R., & Pereira, D. A. G. (2015) · Jornal Vascular Brasileiro · doi:10.1590/1677-5449.002115 · Cited by 7
van Hooff, M., Schep, G., Bender, M. H., Scheltinga, M. R., & Savelberg, H. H. C. M. (2020) · The Physician and Sportsmedicine · doi:10.1080/00913847.2020.1796182 · Cited by 7
“peripheral vascular disease or chronic heart failure [11,12].”
BackgroundVerhaeghe, C., Lapage, K. G., & Moerman, A. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00648-6 · Cited by 7
Brain-muscle interplay during endurance self-paced exercise in normobaric and hypobaric hypoxia
Rupp, T., SAUGY, J. J., Bourdillon, N., & Millet, G. P. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.893872 · Cited by 8
“is increasingly used to measure the (mis)balance between oxygen supply and utilization directly in tissue micro-vessels (venules, arterioles and capillaries), with a predominant venous contribution (70–80%) (Hamaoka et al., 2007).”
Background
Metadata
- Authors
- Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B.
- Affiliations
- Tokyo Medical College
- University of Georgia (US)
- University of L'Aquila (IT)
- Hokkaido University (JP)
- University of Pennsylvania (US)
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2007-11-01
- Volume
- 12
- Issue
- 06
- Pages
- 1-16
- ISSN
- 1083-3668 (ISSN-L)
- 1560-2281
- OpenAlex
- W4297832436
- Cited by
- 329
- References
- 222
- Citations by year
- 2026: 15 · 2025: 6 · 2024: 14 · 2023: 12 · 2022: 18 · 2021: 19 · 2020: 19 · 2019: 25 · 2018: 17 · 2017: 21 · 2016: 18 · 2015: 20 · 2014: 13 · 2013: 17 · 2012: 26
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomedical Optics (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- near-infrared spectroscopy, near-infrared imaging, muscle oxygenation, skeletal muscle oxidative metabolism, muscle oxygen dynamics, signal quantification, physical activity, ischemia, chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, myopathy, spinal cord injury, renal failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.