Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans
Open accessThe DOI matches its Crossref record; 148 of the 230 references it cites were found in a registry or an index, and 81 are not checked yet.
Abstract
Near-infrared spectroscopy (NIRS) was initiated in 1977 by Jobsis as a simple, noninvasive method for measuring the presence of oxygen in muscle and other tissues in vivo. This review honoring Jobsis highlights the progress that has been made in developing and adapting NIRS and NIR imaging (NIRI) technologies for evaluating skeletal muscle O2 dynamics and oxidative energy metabolism. Development of NIRS/NIRI technologies has included novel approaches to quantification of the signal, as well as the addition of multiple source detector pairs for imaging. Adaptation of NIRS technology has focused on the validity and reliability of NIRS measurements. NIRS measurements have been extended to resting, ischemic, localized exercise, and whole body exercise conditions. In addition, NIRS technology has been applied to the study of a number of chronic health conditions, including patients with chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, varying muscle diseases, spinal cord injury, and renal failure. As NIRS technology continues to evolve, the study of skeletal muscle function with NIRS first illuminated by Jobsis continues to be bright.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When debating a specific gold standard to which NIRS-derived SmO2 should be compared, an obvious lack of authority exists as the term is not mentioned in reviews,6,20,21 with appropriate hesitation.”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [20]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationOwen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Self-citationDuncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Mancini, D. M., Katz, S. D., Lang, C. C., LaManca, J., Hudaihed, A., & Androne, A.-S. (2003) · Circulation · doi:10.1161/01.cir.0000044914.42696.6a · Cited by 542
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 3×
“light source to the detector is that it follows a banana-shaped curve, in which the penetration depth into the tissue is approximately equal to half the distance between the light source and the detector.(23) If light source-detector separation”
BackgroundMethodSelf-citationAbnormal Cardiac and Skeletal Muscle Energy Metabolism in Patients With Type 2 Diabetes
Scheuermann-Freestone, M., Madsen, P. L., Manners, D., Blamire, A. M., Buckingham, R. E., Styles, P., Radda, G. K., Neubauer, S., & Clarke, K. (2003) · Circulation · doi:10.1161/01.cir.0000072789.89096.10 · Cited by 525
Research works printed but not linked: 9
- V. Quaresima, R. Lepanto, and M. Ferrari, "The use of near infrared spectroscopy in sports medicine," J. Sports Med. Phys. Fitness 43, 1-13 ͑2003͒.
- K. K. McCully and T. Hamaoka, "Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle?," Exerc Sport Sci. Rev. 28, 123-127 ͑2000͒.
- M. Niwayama, K. Yamamoto, D. Kohata, K. Hirai, N. Kudo, T. Hamaoka, R. Kime, and T. Katsumura, "A 200-channel imaging sys- tem of muscle oxygenation using CW near-infrared spectroscopy," IEICE Trans. Inf. Syst. E85-D, 115-123 ͑2002͒.
- B. Chance, D. J. Wang, S. Nioka, Z. Wang, E. A. Noyszewski, T. Hamaoka, and J. S. Leigh, Jr., "Myoglobin and hemoglobin deoxy- genation during muscle exercise in dogs," Specialty Conf. Am. Col- lege Sports Med. Regulation Oxidative Metab. Blood Flow Skele. Muscle abstract, p. 20 ͑1995͒.
- O. Piazza, G. Zito, A. Valente, and R. Tufano, "Effects of dopamine infusion on forearm blood flow in critical patients," Med. Sci. Monit 12, CR90-93 ͑2006͒.
- Buono, 2005, Eur. J. Vasc. Surg., 55, 241
- Komiyama, 1996, Int. Angiol, 15, 215
- Belardinelli, 1995, G. Ital. Cardiol., 25, 715
- Tateishi, 2005, Osaka City Med. J., 51, 65
Cited by
Items 201–300 of 652
Noninvasive Tracking of Hematopoietic Stem Cells in a Bone Marrow Transplant Model
Oliveira, F. A., Nucci, M. P., Filgueiras, I. S., Ferreira, J. M., Nucci, L. P., Mamani, J. B., Alvieri, F., de Souza, L. E. B., Rego, G. N. A., Kondo, A. T., et al. (2020) · Cells · doi:10.3390/cells9040939 · Cited by 28
Differences in oxygen re-saturation of thigh and calf muscles after two treadmill stress tests
Quaresima, V., Komiyama, T., & Ferrari, M. (2002) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/s1095-6433(01)00531-1 · Cited by 29
Self-citationLimitation of muscle deoxygenation in the triceps during incremental arm cranking in women
Muraki, S., Tsunawake, N., & Yamasaki, M. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0962-8 · Cited by 27
Chung, D. E., Lee, R. K., Kaplan, S. A., & Te, A. E. (2010) · The Journal of Urology · doi:10.1016/j.juro.2010.08.027 · Cited by 27
Skeletal Muscle Deoxygenation Abnormalities in Early Post-Myocardial Infarction
Takagi, S., Murase, N., Kime, R., Niwayama, M., Osada, T., & Katsumura, T. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000334 · Cited by 28
Fuse, S., Endo, T., Tanaka, R., Kuroiwa, M., Ando, A., Kume, A., Yamamoto, A., Kuribayashi, K., Somekawa, S., Takeshita, M., et al. (2020) · Nutrients · doi:10.3390/nu12092676 · Cited by 28
“Resting VO2 rate in the muscle and subcutaneous fat was evaluated by the brief arterial occlusion method using NIRTRS [28,35].”
BackgroundMethodInfluentialSelf-citationMaikala, R. V., & BHAMBHANI, Y. N. (2006) · Experimental Physiology · doi:10.1113/expphysiol.2006.033696 · Cited by 31
Tran, T. N., Yamamoto, K., Namita, T., Kato, Y., & Shimizu, K. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001321 · Cited by 27
Self-citationZhang, Z., Wang, B., Gong, H., Xu, G., Nioka, S., & Chance, B. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3309741 · Cited by 34
“Our endurance-trained rowers have little subcutaneous adipose on the surface of the measured muscles, so most of the NIRS signals detected came from the measured muscles, and the adipose tissue did not affect the related trends in muscle oxygenation.(30) The nature of CW NIRS measurement is still qualitative,(16,30) m…”
BackgroundSelf-citationNear infrared spectroscopy-guided exercise training for claudication in peripheral arterial disease
Murrow, J. R., Brizendine, J. T., Djire, B., Young, H., Rathbun, S. L., Nilsson, K. R., & McCully, K. K. (2018) · European Journal of Preventive Cardiology · doi:10.1177/2047487318795192 · Cited by 29
Self-citationHamaoka, T., Nirengi, S., Fuse, S., Amagasa, S., Kime, R., Kuroiwa, M., Endo, T., Sakane, N., Matsushita, M., Saito, M., et al. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00261 · Cited by 27
“NIRTRS is able to quantitatively measure the absorption coefficient (μa), μs, and then calculates light path length, tissue [oxy-Hb], [deoxy-Hb], [total-Hb], and StO2 (44, 45, 48).”
BackgroundMethodSelf-citationC reactive protein: impact on peripheral tissue oxygenation and perfusion in neonates
Pichler, G., Pocivalnik, M., Riedl, R., Pichler-Stachl, E., Zotter, H., Müller, W. D., & Urlesberger, B. (2012) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2011-300578 · Cited by 26
Akima, H., & Ando, R. (2016) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12370 · Cited by 29
Serena, T. E., Yaakov, R. A., Serena, L., Mayhugh, T., & Harrell, K. (2020) · Journal of Wound Care · doi:10.12968/jowc.2020.29.sup6.s4 · Cited by 26
Macnab, A. J., Shadgan, B., Stothers, L. S., & Afshar, K. (2013) · Canadian Urological Association Journal · doi:10.5489/cuaj.271 · Cited by 28
Muscle oxygen consumption by NIRS and mobility in multiple sclerosis patients
Malagoni, A. M., Felisatti, M., Lamberti, N., Basaglia, N., Manfredini, R., Salvi, F., Zamboni, P., & Manfredini, F. (2013) · BMC Neurology · doi:10.1186/1471-2377-13-52 · Cited by 29
“; licensee BioMed Centr Commons Attribution License (http://creativec reproduction in any medium, provided the or in health and disease [3-9].”
BackgroundAerobic training enhances muscle deoxygenation in early post-myocardial infarction
Takagi, S., Murase, N., Kime, R., Niwayama, M., Osada, T., & Katsumura, T. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3326-x · Cited by 25
A synopsis of brown adipose tissue imaging modalities for clinical research
Sun, L., Yan, J., Sun, L., Velan, S. S., & Leow, M. K. (2017) · Diabetes & Metabolism · doi:10.1016/j.diabet.2017.03.008 · Cited by 27
Cocking, S., Ihsan, M., Jones, H., Hansen, C., Cable, N. T., Thijssen, D. H. J., & Wilson, M. G. (2020) · European Journal of Sport Science · doi:10.1080/17461391.2020.1749312 · Cited by 28
Dunst, A. K., Manunzio, C., Feldmann, A., & Hesse, C. (2023) · Biology of Sport · doi:10.5114/biolsport.2023.122481 · Cited by 29
“The application of the Beer-Lambert law to near-infrared spectroscopy (NIRS) allows for non-invasive and convenient measurement of changes in local muscle tissue oxygenation [2–4].”
MethodYurt, M., Süer, E., Gülpınar, Ö., Telli, O., & Arıkan, N. (2012) · Urology · doi:10.1016/j.urology.2012.03.022 · Cited by 28
Ota, N., Soga, S., & Shimotoyodome, A. (2016) · Bioscience Biotechnology and Biochemistry · doi:10.1080/09168451.2016.1224638 · Cited by 29
Zinner, C., Born, D., & Sperlich, B. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.01029 · Cited by 25
Relationships between plasma lipidomic profiles and brown adipose tissue density in humans
Fuse, S., Sugimoto, M., Kurosawa, Y., Kuroiwa, M., Aita, Y., Tomita, A., Yamaguchi, E., Tanaka, R., Endo, T., Kime, R., et al. (2020) · International Journal of Obesity · doi:10.1038/s41366-020-0558-y · Cited by 26
Self-citationLanfranconi, F., Pollastri, L., Ferri, A., Fraschini, D., Masera, G., & Miserocchi, G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099282 · Cited by 25
Pichler, G., Grossauer, K., Peichl, E., Gaster, A., Berghold, A., Schwantzer, G., Zotter, H., Müller, W. D., & Urlesberger, B. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3076193 · Cited by 25
Klusiewicz, A., Rębiś, K., Ozimek, M., & Czaplicki, A. (2021) · Biology of Sport · doi:10.5114/biolsport.2021.103571 · Cited by 24
Muthalib, M., Jubeau, M., Millet, G. Y., Maffiuletti, N. A., & Nosaka, K. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1118-2 · Cited by 24
“Since recovery of DTOI after exercise is related to PCr resynthesis and/or rate of blood flow/oxygen supply (Hamaoka et al. 2007; Kime et al. 2003), the similar Fig.”
InfluentialNIRS Measurement of O2 Dynamics in Contracting Blood and Buffer Perfused Hindlimb Muscle
Masuda, K., Takakura, H., Furuichi, Y., Iwase, S., & Jue, T. (2009) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-1241-1_46 · Cited by 24
Characterization of the peripheral artery disease symptom experience
Schorr, E. N., Peden‐McAlpine, C., Treat‐Jacobson, D., & Lindquist, R. A. (2015) · Geriatric Nursing · doi:10.1016/j.gerinurse.2015.03.004 · Cited by 25
Enhanced muscular oxygen extraction in athletes exaggerates hypoxemia during exercise in hypoxia
Thienen, R. V., & Hespel, P. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00210.2015 · Cited by 27
Hu, G., Zhang, Q., Ivković, V., & Strangman, G. E. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091314 · Cited by 25
Yarar‐Fisher, C., Pascoe, D. D., Gladden, L. B., Quindry, J. C., Hudson, J. A., & Sefton, J. M. (2013) · Disability and Rehabilitation · doi:10.3109/09638288.2013.782358 · Cited by 28
Turner, L. A., Tecklenburg-Lund, S., Chapman, R. F., Shei, R., Wilhite, D. P., & Mickleborough, T. D. (2016) · International Journal of Sports Medicine · doi:10.1055/s-0042-104198 · Cited by 31
(2012) · Europe PMC (PubMed Central) · Cited by 23
Exercise training in older adults, what effects on muscle oxygenation? A systematic review
Fiogbé, E., Vassimon‐Barroso, V., & Takahashi, A. C. D. M. (2017) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2017.03.001 · Cited by 26
“Nevertheless, other studies also reported muscle oxygenation disorders in clinical conditions such as heart failure (39), chronic obstructive pulmonary disease (40), renal failure (41), diabetes (42), frailty syndrome and sarcopenia (11) as well as other pathologies (43,44).”
BackgroundHeskamp, L., Lebbink, F., van Uden, M. J., Maas, M. C., Claassen, J. A. H. R., Froeling, M., Kemp, G. J., Boss, A., & Heerschap, A. (2020) · The Journal of Physiology · doi:10.1113/jp280771 · Cited by 23
Mizuno, M., Tokizawa, K., Iwakawa, T., & Muraoka, I. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00213.2004 · Cited by 23
Evidence that large vessels do affect near infrared spectroscopy
Seddone, S., Ermini, L., Policastro, P., Mesin, L., & Roatta, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-05863-y · Cited by 23
Dwivedi, A., Groll, H., & Beckerle, P. (2022) · Sensors · doi:10.3390/s22176319 · Cited by 24
“They attribute this observation to the increased pressure of muscles and blood vessels as a result of increasing forces being exerted, which leads to a limited flow of blood in the blood vessels [105].”
BackgroundHachiya, T., Walsh, M. L., Saito, M., & Blaber, A. P. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00593.2009 · Cited by 25
Macnab, A. J., Shadgan, B., & Stothers, L. S. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.963 · Cited by 23
Gollie, J. M., Herrick, J. E., Keyser, R. E., Chin, L. M. K., Collins, J. P., Shields, R. K., Panza, G. S., & Guccione, A. A. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3685-y · Cited by 23
Ishii, K., Matsukawa, K., Liang, N., Endo, K., Idesako, M., Hamada, H., Ueno, K., & Kataoka, T. (2013) · Physiological Reports · doi:10.1002/phy2.92 · Cited by 22
Localized muscle fatigue: review of three experiments
Kumar, S. (2006) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552006000100003 · Cited by 24
Nybäck, L., Glännerud, C., Larsson, G., Weitzberg, E., Shannon, O. M., & McGawley, K. (2017) · Nitric Oxide · doi:10.1016/j.niox.2017.08.001 · Cited by 21
Brain Damage - Bridging Between Basic Research and Clinics
González-Quevedo, A. (2012) · InTech eBooks · doi:10.5772/2174 · Cited by 22
“(Hamaoka et al 2007; Ferrari et al 2011; Wolf et al 2007) Examples of such changes include: an increase or decrease in O2Hb (an indirect measure of oxygen content); an increase or decrease in the total haemoglobin - tHb [O2Hb + HHb] (change in blood volume); an abrupt decrease in O2Hb with…”
BackgroundMulti-modality optical neural imaging using coherence control of VCSELs
Munro, E. A., Levy, H., Ringuette, D., O’Sullivan, T. D., & Levi, O. (2011) · Optics Express · doi:10.1364/oe.19.010747 · Cited by 21
Ishii, K., Matsukawa, K., Liang, N., Endo, K., Idesako, M., Asahara, R., Kadowaki, A., Wakasugi, R., & Takahashi, M. K. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00103.2016 · Cited by 21
Richard, P., & Billaut, F. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-4015-8 · Cited by 26
Agbangla, N. F., Audiffren, M. F., & Albinet, C. T. (2017) · Physiological Research · doi:10.33549/physiolres.933612 · Cited by 21
Paradis‐Deschênes, P., Lapointe, J., Joanisse, D. R., & Billaut, F. (2020) · PubMed Central · Cited by 31
KUROSAWA, Y., Nirengi, S., TABATA, I., Isaka, T., Clark, J. F., & HAMAOKA, T. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002822 · Cited by 22
“0 cm, providing approximately 4-cm(3) measurement volume (23,24).”
BackgroundSelf-citationLocal and remote thermoregulatory changes affect NIRS measurement in forearm muscles
Messere, A., & Roatta, S. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3208-7 · Cited by 22
The effects of work experience, lift frequency and exposure duration on low back muscle oxygenation
Yang, G., Chany, A.-M., Parakkat, J., Burr, D. L., & Marras, W. S. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.07.005 · Cited by 21
Ferrante, S., Contini, D., Spinelli, L., Pedrocchi, A., Torricelli, A. M., Molteni, F., Ferrigno, G., & Cubeddu, R. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3183802 · Cited by 21
Muscle oxygenation during prolonged electrical stimulation-evoked cycling in paraplegics
Muraki, S., Fornusek, C., Raymond, J., & Davis, G. M. (2007) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-007 · Cited by 21
Ferri, A., Adamo, S., Longaretti, M., Marzorati, M., Lanfranconi, F., Marchi, A., & Grassi, B. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0371-x · Cited by 25
Lin, C.-W., Huang, C.-F., Wang, J.-S., Fu, L.-L., & Mao, T.-Y. (2020) · Saudi Journal of Biological Sciences · doi:10.1016/j.sjbs.2020.03.005 · Cited by 20
“…of muscle deoxygenation during the GXT. NIRS is a valid method that can be used to determine VT during exercise as previously confirmed in many populations, including normal subjects, children (Moalla et al., 2005), patients (Hamaoka et al., 2007), and athletes (van der Zwaard et al., 2016).”
BackgroundMethodBrindha, M., Seshadri, N. P. G., & Periyasamy, R. (2021) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-210211 · Cited by 20
“NIRS is a non-invasive procedure used for the measurement of tissue oxygenation level based on the spectrophotometric method of oxy-and de-oxyhemoglobin within a tissue [10,19].”
Pichler, G., Pocivalnik, M., Riedl, R., Pichler-Stachl, E., Morris, N., Zotter, H., Müller, W. D., & Urlesberger, B. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/8/003 · Cited by 21
Fortin, J.-F., & Billaut, F. (2019) · Sports · doi:10.3390/sports7050121 · Cited by 21
Carbon monoxide exposure during exercise performance: muscle and cerebral oxygenation
Keramidas, M. E., Kounalakis, S. N., Eiken, O., & Mekjavic, I. B. (2012) · Acta Physiologica · doi:10.1111/j.1748-1716.2011.02363.x · Cited by 19
NIRS Measurements with Elite Speed Skaters: Comparison Between the Ice Rink and the Laboratory
Hesford, C., Cardinale, M., Laing, S. J., & Cooper, C. E. (2012) · Advances in experimental medicine and biology · doi:10.1007/978-1-4614-4989-8_12 · Cited by 20
“Near-infrared spectroscopy (NIRS) has been used to investigate exercise-specific oxygen metabolism and hemodynamics in the laboratory for a range of sports including: cycling [1, 2]; sailing [3]; and speed skating [4]; for review see [5].”
MethodAdvanced Chronic Venous Insufficiency is Associated with Increased Calf Muscle Deoxygenation
Yamaki, T., Nozaki, M., Sakurai, H., Soejima, K., Kono, T., & Hamahata, A. (2010) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2010.01.031 · Cited by 27
Models of muscle contraction and energetics
Lai, N., Gladden, L. B., Carlier, P. G., & Cabrera, M. E. (2008) · Drug Discovery Today Disease Models · doi:10.1016/j.ddmod.2009.07.001 · Cited by 21
“However, several limitations need to be overcome before NIRS can be fully exploited clinically in the functional evaluation of muscle metabolism in health and disease [50,51,52].”
BackgroundNear‐Infrared Spectroscopy of the Bladder: New Parameters for Evaluating Voiding Dysfunction
Macnab, A. J., Shadgan, B., Afshar, K., & Stothers, L. S. (2011) · International Journal of Spectroscopy · doi:10.1155/2011/814179 · Cited by 22
“involving the microcirculation affects tissue haemodynamics and oxygenation [1, 2, 5]; and understanding of the physiologic mechanisms that determine how a functional microcirculation provides for and responds to changes in oxygen demand [11–13].”
BackgroundInfluentialNiazi, I. K., Kamavuako, E. N., Holt, K. R., Janjua, T. A. M., Kumari, N., Amjad, I., & Haavik, H. (2020) · Healthcare · doi:10.3390/healthcare8040548 · Cited by 20
Broatch, J. R., O’Riordan, S. F., Keske, M. A., Betik, A. C., Bishop, D. J., Halson, S. L., & Parker, L. (2021) · The FASEB Journal · doi:10.1096/fj.202002205rr · Cited by 19
Optical imaging instrument for muscle oxygenation based on spatially resolved spectroscopy
Kek, K. J., Kibe, R., Niwayama, M., Kudo, N., & Yamamoto, K. (2008) · Optics Express · doi:10.1364/oe.16.018173 · Cited by 21
Self-citationHeterogeneity of muscle deoxygenation kinetics during two bouts of repeated heavy exercises
Prieur, F., Berthoin, S., Marles, A., Blondel, N., & Mucci, P. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1446-2 · Cited by 20
The Relationship Between Peripheral Artery Disease Symptomatology and Ischemia
Schorr, E. N., Treat‐Jacobson, D., & Lindquist, R. A. (2017) · Nursing Research · doi:10.1097/nnr.0000000000000230 · Cited by 24
A wearable diffuse reflectance sensor for continuous monitoring of cutaneous blood content
Zakharov, P., Talary, M. S., & Caduff, A. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/17/015 · Cited by 24
“Internal laboratory tests were performed using the procedure of venous occlusion, as described e.g. by Hamaoka (Hamaoka et al 2007) in order to characterize the device response to the induced changes of the CBC and were evaluated with a standardized protocol.”
MethodBHAMBHANI, Y. N., Fan, J., Place, N., Rodríguez-Falces, J., & Kayser, B. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00190 · Cited by 21
Delayed Blood Reoxygenation following Maximum Voluntary Contraction
Maguire, M. A., Weaver, T. W., & Damon, B. M. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000246990.25858.47 · Cited by 20
Intra- and Inter-Day Reliability of the NIRS Portamon Device after Three Induced Muscle Ischemias
Desanlis, J., Gordon, D. A., Calveyrac, C., Cottin, F., & Gernigon, M. (2022) · Sensors · doi:10.3390/s22145165 · Cited by 19
“By using NIRS-derived reoxygenation rate parameters, it is possible to differentiate between trained and untrained participants [8], as well as healthy participants and diseased patients [18].”
MethodSiqueira, A. C. B., Borghi‐Silva, A., Bravo, D. M., Ferreira, E. V. M., Chiappa, G. R., & Neder, J. A. (2010) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.04.020 · Cited by 22
Oxygen uptake kinetics in chronic heart failure: clinical and physiological aspects
Kemps, H., Schep, G., Hoogsteen, J., Thijssen, E. J. M., de Vries, W. R., Zonderland, M. L., & Doevendans, P. A. (2009) · Netherlands Heart Journal · doi:10.1007/bf03086254 · Cited by 22
BHAMBHANI, Y. N. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.978 · Cited by 19
Woodside, J., Gutowski, M., Fall, L., James, P. E., McEneny, J., Young, I. S., Ogoh, S., & Bailey, D. M. (2014) · Experimental Physiology · doi:10.1113/expphysiol.2014.081265 · Cited by 21
Lin, T.-Y., Wu, J., Lin, L. L.-C., Ho, T. C., Lin, P., & Chen, J. J. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2429655 · Cited by 18
Giacona, J. M., Petric, U. B., Kositanurit, W., Wang, J., Saldanha, S., Young, B. E., Khan, G., Connelly, M. A., Smith, S. A., Rohatgi, A. K., et al. (2024) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00017.2024 · Cited by 17
Monitoring Detrusor Oxygenation and Hemodynamics Noninvasively during Dysfunctional Voiding
Macnab, A. J., Stothers, L. S., & Shadgan, B. (2012) · Advances in Urology · doi:10.1155/2012/676303 · Cited by 17
“Under these circumstances during work involving contraction the functional capacity of the muscle or organ is adversely affected and symptoms of dysfunction result [2, 8, 9, 25, 28, 32].”
BackgroundBarberán-García, A., Muñoz, P. A., Gimeno‐Santos, E., Burgos, F., Torralba, Y., Gistau, C., Roca, J., & Rodriguez, D. A. (2019) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12572 · Cited by 19
“…through significant achievements in terms of standardization of the technique leading to acceptable robustness of measurements (Bhambhani, 2004; Ferrari et al., 2004; Hamaoka et al., 2007) and well-established usefulness for monitoring in intensive care (Pareznik et al., 2006; Cohn et al., 2007).”
BackgroundMethodHwang, H., Mizuno, S., Kasai, N., Kojima, C., Sumi, D., Hayashi, N., & Goto, K. (2020) · Physical Activity and Nutrition · doi:10.20463/pan.2020.0012 · Cited by 17
“As an individual starts the exercise, oxygen consumption and delivery to the skeletal muscle rapidly increases, up to 50-fold or more 19 .”
BackgroundTabira, K., Horie, J., Fujii, H., Aida, T., Ito, K., Fukumoto, T., Imagita, H., & Ishihara, H. (2012) · Respiratory Care · doi:10.4187/respcare.01602 · Cited by 20
Mohammadi, A., Ma, L., Yang, Y., Song, Y., & Wang, J. (2019) · Medical Acupuncture · doi:10.1089/acu.2019.1362 · Cited by 17
Influence of muscle fibre composition on muscle oxygenation during maximal running
Kitada, T., Machida, S., & Naıto, H. (2015) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000062 · Cited by 19
“NIRS parameters are influenced by the light path length.(2) 10 Therefore, to enable a comparison between participants, the value was”
Backgroundİspirgil, E., Erdoğan, S. B., Akın, A., & Şakar, O. (2018) · CRANIO® · doi:10.1080/08869634.2018.1491929 · Cited by 20
“NIRS has been used to differentiate healthy and pathological tissues [12,13,21].”
BackgroundMethodKinetic differences between macro- and microvascular measures of reactive hyperemia
Bartlett, M. F., Oneglia, A. P., JAFFERY, M. F., Manitowabi-Huebner, S., Hueber, D. M., & Nelson, M. D. (2020) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00481.2020 · Cited by 16
Oueslati, F., Boone, J., & Ahmaïdi, S. (2016) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2016.02.008 · Cited by 18
Morishita, S., Wakasugi, T., Kaida, K., Itani, Y., Ikegame, K., Ogawa, H., & Domen, K. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-91287-5_47 · Cited by 17
Algorithm construction methodology for diagnostic classification of near-infrared spectroscopy data
Erra, R. G., Stothers, L. S., & Macnab, A. J. (2011) · Spectroscopy An International Journal · doi:10.1155/2011/752101 · Cited by 19
Wang, B., Tian, Q., Zhang, Z., & Gong, H. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2007-z · Cited by 15
“2001) has been introduced to the exercise physiology detection and has promoted our understanding of the aerobic metabolism in local skeletal muscles (Wolf et al. 2007; Hamaoka et al. 2007; Bhambhani 2004; Boushel et al. 2001; Zhang et al. 2010; Sako et al. 2001).”
BackgroundMethodInfluentialReproducibility of NIRS-derived mitochondrial oxidative capacity in highly active older adults
Fennell, C. R. J., Mauger, A. R., & Hopker, J. (2023) · Experimental Gerontology · doi:10.1016/j.exger.2023.112156 · Cited by 17
Ji, W., Nightingale, T. E., Zhao, F., Fritz, N. E., Phillips, A. A., Sisto, S. A., Nash, M. S., Badr, M. S., Wecht, J. M., Mateika, J. H., et al. (2023) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2023.08.006 · Cited by 15
Tripp, T. R., McDougall, R. M., Frankish, B. P., Wiley, J. P., Lun, V. M. Y., & MacInnis, M. J. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00342.2023 · Cited by 15
The influence of sex, hemoglobin mass, and skeletal muscle characteristics on cycling critical power
Caswell, A. M., Tripp, T. R., Kontro, H., Edgett, B. A., Wiley, J. P., Lun, V. M. Y., & MacInnis, M. J. (2024) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00120.2024 · Cited by 16
The Effect of Static Stretching Duration on Muscle Blood Volume and Oxygenation
Matsuo, H., Kubota, M., Shimada, S., Kitade, I., Matsumura, M., Nonoyama, T., Koie, Y., Naruse, H., Takahashi, A., Oki, H., et al. (2020) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003457 · Cited by 17
Evaluation of venous return in lower limb by passive ankle exercise performed by PHARAD
Yonezawa, T., Nomura, K., Onodera, T., Ichimura, S., Mizoguchi, H., & Takemura, H. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319167 · Cited by 15
Metadata
- Authors
- Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B.
- Affiliations
- Tokyo Medical College
- University of Georgia (US)
- University of L'Aquila (IT)
- Hokkaido University (JP)
- University of Pennsylvania (US)
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2007-11-01
- Volume
- 12
- Issue
- 06
- Pages
- 1-16
- ISSN
- 1083-3668 (ISSN-L)
- 1560-2281
- OpenAlex
- W4297832436
- Semantic Scholar
- 2bda5bdb3ef3a60cc093249ee0e38d98c8f71ea5
- Cited by
- 329
- References
- 222
- Citations by year
- 2026: 15 · 2025: 6 · 2024: 14 · 2023: 12 · 2022: 18 · 2021: 19 · 2020: 19 · 2019: 25 · 2018: 17 · 2017: 21 · 2016: 18 · 2015: 20 · 2014: 13 · 2013: 17 · 2012: 26
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomedical Optics (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- near-infrared spectroscopy, near-infrared imaging, muscle oxygenation, skeletal muscle oxidative metabolism, muscle oxygen dynamics, signal quantification, physical activity, ischemia, chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, myopathy, spinal cord injury, renal failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.