Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans
Open accessThe DOI matches its Crossref record; 148 of the 230 references it cites were found in a registry or an index, and 81 are not checked yet.
Abstract
Near-infrared spectroscopy (NIRS) was initiated in 1977 by Jobsis as a simple, noninvasive method for measuring the presence of oxygen in muscle and other tissues in vivo. This review honoring Jobsis highlights the progress that has been made in developing and adapting NIRS and NIR imaging (NIRI) technologies for evaluating skeletal muscle O2 dynamics and oxidative energy metabolism. Development of NIRS/NIRI technologies has included novel approaches to quantification of the signal, as well as the addition of multiple source detector pairs for imaging. Adaptation of NIRS technology has focused on the validity and reliability of NIRS measurements. NIRS measurements have been extended to resting, ischemic, localized exercise, and whole body exercise conditions. In addition, NIRS technology has been applied to the study of a number of chronic health conditions, including patients with chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, varying muscle diseases, spinal cord injury, and renal failure. As NIRS technology continues to evolve, the study of skeletal muscle function with NIRS first illuminated by Jobsis continues to be bright.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When debating a specific gold standard to which NIRS-derived SmO2 should be compared, an obvious lack of authority exists as the term is not mentioned in reviews,6,20,21 with appropriate hesitation.”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [20]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationOwen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Self-citationDuncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Mancini, D. M., Katz, S. D., Lang, C. C., LaManca, J., Hudaihed, A., & Androne, A.-S. (2003) · Circulation · doi:10.1161/01.cir.0000044914.42696.6a · Cited by 542
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 3×
“light source to the detector is that it follows a banana-shaped curve, in which the penetration depth into the tissue is approximately equal to half the distance between the light source and the detector.(23) If light source-detector separation”
BackgroundMethodSelf-citationAbnormal Cardiac and Skeletal Muscle Energy Metabolism in Patients With Type 2 Diabetes
Scheuermann-Freestone, M., Madsen, P. L., Manners, D., Blamire, A. M., Buckingham, R. E., Styles, P., Radda, G. K., Neubauer, S., & Clarke, K. (2003) · Circulation · doi:10.1161/01.cir.0000072789.89096.10 · Cited by 525
Research works printed but not linked: 9
- V. Quaresima, R. Lepanto, and M. Ferrari, "The use of near infrared spectroscopy in sports medicine," J. Sports Med. Phys. Fitness 43, 1-13 ͑2003͒.
- K. K. McCully and T. Hamaoka, "Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle?," Exerc Sport Sci. Rev. 28, 123-127 ͑2000͒.
- M. Niwayama, K. Yamamoto, D. Kohata, K. Hirai, N. Kudo, T. Hamaoka, R. Kime, and T. Katsumura, "A 200-channel imaging sys- tem of muscle oxygenation using CW near-infrared spectroscopy," IEICE Trans. Inf. Syst. E85-D, 115-123 ͑2002͒.
- B. Chance, D. J. Wang, S. Nioka, Z. Wang, E. A. Noyszewski, T. Hamaoka, and J. S. Leigh, Jr., "Myoglobin and hemoglobin deoxy- genation during muscle exercise in dogs," Specialty Conf. Am. Col- lege Sports Med. Regulation Oxidative Metab. Blood Flow Skele. Muscle abstract, p. 20 ͑1995͒.
- O. Piazza, G. Zito, A. Valente, and R. Tufano, "Effects of dopamine infusion on forearm blood flow in critical patients," Med. Sci. Monit 12, CR90-93 ͑2006͒.
- Buono, 2005, Eur. J. Vasc. Surg., 55, 241
- Komiyama, 1996, Int. Angiol, 15, 215
- Belardinelli, 1995, G. Ital. Cardiol., 25, 715
- Tateishi, 2005, Osaka City Med. J., 51, 65
Cited by
Items 101–200 of 652
Nonuniform Quadriceps O2 Consumption Revealed by Near Infrared Multipoint Measurements
Quaresima, V., Colier, W. N. J. M., van der Sluijs, M. C., & Ferrari, M. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5292 · Cited by 61
Self-citationManfredini, F., Malagoni, A. M., Mandini, S., Felisatti, M., Mascoli, F., Basaglia, N., Manfredini, R., Mikhailidis, D. P., & Zamboni, P. (2012) · Vascular and Endovascular Surgery · doi:10.1177/1538574412443318 · Cited by 59
Malagoni, A. M., Felisatti, M., Mandini, S., Mascoli, F., Manfredini, R., Basaglia, N., Zamboni, P., & Manfredini, F. (2010) · Angiology · doi:10.1177/0003319710362975 · Cited by 52
Anne, M.-L., Lan, C. L., Monbet, V., Boussard‐Plédel, C., Ropert, M., Sire, O., Pouchard, M., Jard, C., Lucas, J., Adam, J., et al. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3253319 · Cited by 56
Which common NIRS variable reflects muscle estimated lactate threshold most closely?
Wang, L., Yoshikawa, T., Hara, T., Nakao, H., Suzuki, T., & Fujimoto, S. (2006) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h06-069 · Cited by 54
Ischemic Preconditioning Improves Time Trial Performance at Moderate Altitude
Paradis‐Deschênes, P., Joanisse, D. R., & Billaut, F. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001473 · Cited by 61
Miura, H., McCully, K., Hong, L., Nioka, S., & Chance, B. (2001) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.51.599 · Cited by 54
Self-citationPériard, J. D., Thompson, M. W., Caillaud, C., & Quaresima, V. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2427-4 · Cited by 58
Self-citationStothers, L. S., Erra, R. G., & Macnab, A. J. (2009) · European Urology · doi:10.1016/j.eururo.2009.05.004 · Cited by 57
Macnab, A. J., & Stothers, L. S. (2008) · PubMed · Cited by 59
Oxygen Uptake and Muscle Desaturation Kinetics during Intermittent Cycling
TURNER, A. P., CATHCART, A. J., PARKER, M. E., BUTTERWORTH, C., WILSON, J., & WARD, S. A. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000188450.82733.f0 · Cited by 53
Reduced skeletal muscle oxidative capacity and impaired training adaptations in heart failure
Southern, W. M., RYAN, T. E., Kepple, K., Murrow, J. R., Nilsson, K. R., & McCully, K. K. (2015) · Physiological Reports · doi:10.14814/phy2.12353 · Cited by 56
“…measure the oxidative capacity, a short duration exercise was used increase skeletal muscle oxygen consumption followed by repeated arterial occlusions to measure the rate of recovery of mVO2 as previously described (Motobe et al. 2004; Hamaoka et al. 2007; Buchheit et al. 2011; Ryan et al. 2012).”
MethodSelf-citationKerhervé, H. A., Samozino, P., Descombe, F., Pinay, M., Millet, G. Y., Pasqualini, M., & Rupp, T. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00247 · Cited by 52
“As previously described (Hamaoka et al., 2007), mV̇O2 was estimated using the initial rate of muscle deoxygenation measured by NIRS during two 20-s arterial occlusions (280 mmHg) separated by 45 s of rest.”
MethodAnkri, R., & Fixler, D. (2017) · Nanophotonics · doi:10.1515/nanoph-2017-0033 · Cited by 52
Bopp, C. M., Townsend, D. K., & Barstow, T. J. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1898-z · Cited by 64
“Near-infrared spectroscopy (NIRS) allows for the non-invasive assessment of the concentration of oxygenated (oxy[Hb?Mb]) and deoxygenated hemoglobin ? myoglobin (deoxy[Hb?Mb]) in skeletal muscle (Hamaoka et al. 2007).”
BackgroundEspectroscopia no infravermelho próximo para a monitorização da perfusão tecidual
JUNIOR, A. A. D. L., & Bakker, J. (2011) · Revista Brasileira de Terapia Intensiva · doi:10.1590/s0103-507x2011000300013 · Cited by 71
Blood Flow Restriction Exercise in Sprinters and Endurance Runners
Takada, S., Okita, K., Suga, T., Omokawa, M., Morita, N., Horiuchi, M., Kadoguchi, T., Takahashi, M., Hirabayashi, K., Yokota, T., et al. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31822f39b3 · Cited by 62
Boezeman, R. P. E., Becx, B. P., van den Heuvel, D. A. F., Ünlü, Ç., Vos, J. A., & de Vries, J. P. P. M. (2016) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2016.07.020 · Cited by 56
Ma, N., de Mochel, N. R., Pham, P. D., Yoo, T. Y., Cho, K. W. Y., & Digman, M. A. (2019) · Scientific Reports · doi:10.1038/s41598-019-48107-2 · Cited by 53
Shadgan, B., Guenette, J. A., Sheel, A. W., & Reid, W. D. (2011) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2011.06.001 · Cited by 57
Emerging Technologies and their Applications in Lipid Compartment Measurement
Heymsfield, S. B., Hu, H. H., Shen, W., & Carmichael, O. (2015) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2015.10.003 · Cited by 47
“Novel time-resolved Fourier transform infrared (FTIR) sensing techniques, meanwhile, provide much richer information about tissue composition including the path length of light, absorption, scattering, and concentrations of tissue oxygen and hemoglobin [74, 75].”
BackgroundComparative NMR and NIRS analysis of oxygen-dependent metabolism in exercising finger flexor muscles
Bendahan, D., Chatel, B., & Jue, T. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00203.2017 · Cited by 47
Karlas, A., Kallmayer, M. A., Fasoula, N., Liapis, E., Bariotakis, M., Krönke, M., Anastasopoulou, M., Reber, J., Eckstein, H., & Ntziachristos, V. (2020) · Journal of Biophotonics · doi:10.1002/jbio.201960169 · Cited by 49
Keramidas, M. E., Kounalakis, S. N., & Geladas, N. D. (2011) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2011.01078.x · Cited by 55
Age and Activity Status Affect Muscle Reoxygenation Time after Maximal Cycling Exercise
ICHIMURA, S., MURASE, N., OSADA, T., KIME, R., HOMMA, T., UEDA, C., NAGASAWA, T., MOTOBE, M., HAMAOKA, T., & KATSUMURA, T. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000227312.08599.f1 · Cited by 47
Self-citationApplications of near infrared spectroscopy and imaging for motor rehabilitation in stroke patients
Lin, P., Chen, J.-J. J., Lin, S.-I., & PENNEY, T. (2009) · National University of Singapore · Cited by 51
Attenuation of Muscle Deoxygenation Precedes EMG Threshold in Normoxia and Hypoxia
OSAWA, T., KIME, R., HAMAOKA, T., KATSUMURA, T., & YAMAMOTO, M. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182100261 · Cited by 46
“The principle, validity, and limitation of the measurements in humans have been previously reported (13,16).”
BackgroundMethodSelf-citationQuantitative Biomedical Optics: Theory, Methods, and Applications
Bigio, I. J., & Fantini, S. (2016) · Cited by 46
YAZICI, M., Livanelioğlu, A., Gücüyener, K., Orgun, L. T., Sümer, E., & Yakut, Y. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.03.017 · Cited by 46
Interpretation of Near-Infrared Spectroscopy (NIRS) Signals in Skeletal Muscle
Sanni, A. A., & McCully, K. K. (2019) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk4020028 · Cited by 46
“Five minutes of ischemia has produced an 80–90% change in oxygen saturation levels [26] and about 80–90% of the maximal hyperemic blood flow response measured with ultrasound [27].”
BackgroundSelf-citationZimmerman, J. J., Arnim, A. V. S. A.-V., & McLaughlin, J. (2011) · Elsevier eBooks · doi:10.1016/b978-0-323-07307-3.10074-6 · Cited by 56
Can muscle shortening alone, explain the energy cost of muscle contraction in vivo?
Fletcher, J. R., Groves, E. M., Pfister, T. R., & MacIntosh, B. R. (2013) · European Journal of Applied Physiology · doi:10.1007/s00421-013-2665-0 · Cited by 50
“A number of thorough reviews have been dedicated to the use of NIRS during exercise (Ferrari et al. 2004; Hamaoka et al. 2007; McCully and Hamaoka 2000; Neary 2004).”
Angelopoulos, E. T., Karatzanos, E., Dimopoulos, S. K., Mitsiou, G., Stefanou, C., Patsaki, I., Kotanidou, A. N., Routsi, C., Petrikkos, G. L., & Nanas, S. (2013) · Annals of Intensive Care · doi:10.1186/2110-5820-3-39 · Cited by 53
“This equilibrium is affected by several factors such as the mechanical pressure on vessels during contraction, blood flow and consequently blood volume, venous return, relative degree of vasoconstriction and vasodilation in the microcirculation [49,50].”
BackgroundPhotoacoustic imaging of hemodynamic changes in forearm skeletal muscle during cuff occlusion
Yang, J., Guang, Z., Chang, W., Chi, Z., Shang, Q., Wu, M., Pan, T., Huang, L., & Jiang, H. (2020) · Biomedical Optics Express · doi:10.1364/boe.392221 · Cited by 45
Arm Blood Flow and Oxygenation on the Transition from Arm to Combined Arm and Leg Exercise in Humans
Volianitis, S., Krustrup, P., Dawson, E., & Secher, N. H. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.034496 · Cited by 44
Urological applications of near infrared spectroscopy.
Stothers, L. S., Shadgan, B., & Macnab, A. J. (2008) · PubMed · Cited by 55
Brain and Muscle near Infrared Spectroscopy/Imaging Techniques
Contini, D., Zucchelli, L. M. G., Spinelli, L., Caffini, M., Re, R., Pifferi, A., Cubeddu, R., & Torricelli, A. M. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.977 · Cited by 50
Luck, J. C., Miller, A. J., Aziz, F., Radtka, J. F., Proctor, D. N., Leuenberger, U. A., Sinoway, L. I., & Muller, M. D. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01110.2016 · Cited by 45
“research has been previously reviewed (21, 65).”
Kime, R., Karlsen, T., Nioka, S., Lech, G., Madsen, Ø., Sæterdal, R., Im, J., Chance, B., & Stray‐Gundersen, J. (2003) · Dynamic Medicine · doi:10.1186/1476-5918-2-4 · Cited by 47
Self-citationInspiratory muscle warm-up attenuates muscle deoxygenation during cycling exercise in women athletes
Cheng, C., Tong, T. K., Kuo, Y., Chen, P.-H., Huang, H.-W., & Lee, C.-L. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.02.029 · Cited by 49
Measuring reactive hyperemia in the lower limb using near-infrared spectroscopy
Willingham, T. B., Southern, W. M., & McCully, K. K. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091302 · Cited by 45
Self-citationGoto, M., Maeda, C., Hirayama, T., Terada, S., Nirengi, S., Kurosawa, Y., Nagano, A., & Hamaoka, T. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002051 · Cited by 47
“Therefore, the changes in the oxygenation of working skeletal muscles are expressed relative to the overall changes in the monitored signal, according to the arterial occlusion method (11).”
MethodSelf-citationNoninvasive Evaluation of Skeletal Muscle Oxidative Metabolism after Heart Transplant
LANFRANCONI, F., BORRELLI, E., FERRI, A., PORCELLI, S., MACCHERINI, M., CHIAVARELLI, M., & GRASSI, B. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000228943.62776.69 · Cited by 48
Kemps, H., Prompers, J. J., Wessels, B., de Vries, W. R., Zonderland, M. L., Thijssen, E. J. M., Nicolay, K., Schep, G., & Doevendans, P. A. (2009) · Clinical Science · doi:10.1042/cs20090220 · Cited by 46
Kennedy, M. D., Haykowsky, M. J., Boliek, C. A., Esch, B. T., Scott, J. M., & Warburton, D. E. (2006) · Dynamic Medicine · doi:10.1186/1476-5918-5-8 · Cited by 38
Binzoni, T., Cooper, C. E., Wittekind, A., Beneke, R., Elwell, C. E., Ville, D. V. D., & Leung, T. S. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/014 · Cited by 47
“…(see, for a review, McCully and Hamaoka (2000), Rolfe (2000), Boushel et al (2001), Quaresima et al (2003), Bhambhani (2004), Ferrari et al (2004), Hamaoka et al (2007), Wolf et al (2007)); the techniques consist of a combination of near-infrared light sources, detectors and specialized…”
BackgroundMethodDiffuse optical characterization of an exercising patient group with peripheral artery disease
Mesquita, R. C., Putt, M., Chandra, M., Yu, G., Xing, X., Han, S. W., Lech, G., Shang, Y., Durduran, T., Zhou, C., et al. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.057007 · Cited by 46
“32,33 Measurements of rBF revealed differences in post-exercise dynamics for healthy and moderate/severe PAD groups.”
BackgroundWarm-up effects on muscle oxygenation, metabolism and sprint cycling performance
Wittekind, A., Cooper, C. E., Elwell, C. E., Leung, T. S., & Beneke, R. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2262-z · Cited by 46
Biceps brachii muscle oxygenation in electrical muscle stimulation
Muthalib, M., Jubeau, M., Millet, G. Y., Maffiuletti, N. A., Ferrari, M., & Nosaka, K. (2010) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2010.00953.x · Cited by 40
“…sampled under the NIRS probe and is affected by the mechanical pressure on vessels during the contraction phase, O2 extraction, blood flow ⁄ volume, venous return, and vasodilation and vasoconstriction in the microcirculation (Boushel et al., 2001; Ferrari et al., 2004; Hamaoka et al., 2007).”
BackgroundMethodInfluentialSpectroscopic optical coherence tomography: A review of concepts and biomedical applications
Nam, H. S., & Yoo, H. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2017.1324876 · Cited by 40
Koga, S., Poole, D. C., Kondo, N., Oue, A., Ohmae, E., & Barstow, T. J. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-014-3019-2 · Cited by 39
Yamada, E., Kusaka, T., Arima, N., Isobe, K., Yamamoto, T., & Itoh, S. (2008) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00798.x · Cited by 47
Muthalib, M., Lee, H.-S., Millet, G. Y., Ferrari, M., & Nosaka, K. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01297.2009 · Cited by 45
“Near-infrared spectroscopy (NIRS) is a noninvasive optical technique that allows for the continuous measurements of muscle oxygenation and hemodynamics (14, 15).”
BackgroundMethodMuscle oxygenation and EMG activity during isometric exercise in children
Moalla, W., Merzouk, A., Costes, F., Tabka, Z., & Ahmaïdi, S. (2006) · Journal of Sports Sciences · doi:10.1080/02640410500457893 · Cited by 39
Peltonen, J. E., Koponen, A. S., Pullinen, K., Hägglund, H., Aho, J. M., Kyröläinen, H., & Tikkanen, H. O. (2012) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2012.04.002 · Cited by 40
Development of a near-infrared spectroscopy instrument for applications in urology.
Macnab, A. J., & Stothers, L. S. (2008) · PubMed · Cited by 44
Skeletal muscle oxidative capacity in amyotrophic lateral sclerosis
RYAN, T. E., Erickson, M. L., Verma, A., Chavez, J. C., Rivner, M. H., & McCully, K. K. (2014) · Muscle & Nerve · doi:10.1002/mus.24223 · Cited by 43
Self-citationTuesta, M., Yáñez-Sepúlveda, R., Verdugo-Marchese, H., Mateluna, C., & Alvear-Ordenes, I. (2022) · Biology · doi:10.3390/biology11071073 · Cited by 37
A compact time-resolved system for near infrared spectroscopy based on wavelength space multiplexing
Re, R., Contini, D., Caffini, M., Cubeddu, R., Spinelli, L., & Torricelli, A. M. (2010) · Review of Scientific Instruments · doi:10.1063/1.3495957 · Cited by 37
Reduced Heterogeneity of Muscle Deoxygenation during Heavy Bicycle Exercise
KIME, R., IM, J., MOSER, D., LIN, Y., NIOKA, S., KATSUMURA, T., & CHANCE, B. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000155401.81284.76 · Cited by 37
Self-citationSkeletal muscle mitochondrial capacity in people with multiple sclerosis
Harp, M. A., McCully, K. K., Moldavskiy, M., & Backus, D. A. (2016) · Multiple Sclerosis Journal - Experimental Translational and Clinical · doi:10.1177/2055217316678020 · Cited by 40
“Mitochondrial capacity can be measured noninvasively in vivo using near-infrared spectroscopy (NIRS).(9) NIRS measures the decrease in oxygen saturation under ischemic conditions as muscle metabolic rate (mVO2), and the rate constant of recovery of mVO2 after either exercise or muscle electrical stimulation has been u…”
BackgroundSelf-citationThe Influence of Passive Stretch on Muscle Oxygen Saturation
McCully, K. K. (2009) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-1241-1_45 · Cited by 36
“Near infrared spectroscopy (NIRS) has been used to evaluate changes in oxygen saturation to skeletal muscle [ 1 ].”
MethodSelf-citationLiebert, A., Wabnitz, H., & Elster, C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.057005 · Cited by 35
Cerebral Regulation in Different Maximal Aerobic Exercise Modes
Pires, F. O., dos Anjos, C. A. S., Covolan, R. J. M., Pinheiro, F. A., Gibson, A. S. C., Noakes, T. D., Magalhães, F. H., & Ugrinowitsch, C. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00253 · Cited by 37
“For example, a 4.5 cm inter-optode distance has been suggested to be unaffected by changes in scalp blood flow or adipose tissue thickness (Hamaoka et al., 2007; Ekkekakis, 2009).”
InfluentialLewis, M. T., Kasper, J. D., Bazil, J. N., Frisbee, J. C., & Wiseman, R. W. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20215271 · Cited by 40
Zuccarelli, L., do Nascimento Salvador, P. C., Del Torto, A., Fiorentino, R., & Grassi, B. (2020) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00580.2019 · Cited by 32
Ishii, K., Liang, N., Oue, A., Hirasawa, A., Sato, K., Sadamoto, T., & Matsukawa, K. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00075.2012 · Cited by 38
Miyamoto, N., Wakahara, T., Ema, R., & Kawakami, Y. (2013) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12054 · Cited by 35
Local increase in trapezius muscle oxygenation during and after acupuncture
Ohkubo, M., Hamaoka, T., Niwayama, M., Murase, N., Osada, T., Kime, R., Kurosawa, Y., Sakamoto, A., & Katsumura, T. (2009) · Dynamic Medicine · doi:10.1186/1476-5918-8-2 · Cited by 37
“as the optical path length in tissue [13,20].”
BackgroundSelf-citationEffects of Vibrations on Gastrocnemius Medialis Tissue Oxygenation
Coza, A., Nigg, B. M., & Dunn, J. F. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181f2589f · Cited by 38
The repeated-bout effect: influence on biceps brachii oxygenation and myoelectrical activity
Muthalib, M., Lee, H.-S., Millet, G. Y., Ferrari, M., & Nosaka, K. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00191.2010 · Cited by 36
“Thus TOI reflects the dynamic balance of O2 supply by the microcirculation and O2 consumption by the mitochondria (15, 21).”
BackgroundCathcart, C. C., Shuler, M. S., Freedman, B. A., Reno, L. R., & Budsberg, S. C. (2013) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3182a75ceb · Cited by 34
Wakasugi, T., Morishita, S., Kaida, K., Itani, Y., Kodama, N., Ikegame, K., Ogawa, H., & Domen, K. (2018) · Supportive Care in Cancer · doi:10.1007/s00520-017-4036-6 · Cited by 35
“In general, the arterial occlusion method is used to measure NIRS in healthy and diseased individuals [5].”
MethodAlbert, W. J., Sleivert, G. G., Neary, J. P., & BHAMBHANI, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-023 · Cited by 38
Effects of Compression on Muscle Tissue Oxygenation at the Onset of Exercise
Coza, A., Dunn, J. F., Anderson, B. J., & Nigg, B. M. (2012) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318254885b · Cited by 38
“The NIRS method has been successfully employed to measure brain and muscle tissue oxygenation in previous studies (3,9).”
BackgroundMethodTissue deoxygenation kinetics induced by prolonged hypoxic exposure in healthy humans at rest
Rupp, T., Leti, T., Jubeau, M., Millet, G. Y., Bricout, V., Levy, P. A., Wuyam, B., Perrey, S., & Vergès, S. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.9.095002 · Cited by 36
“Particularly in the last decade, NIRS has been widely used and recognized as a powerful tool to measure the (mis)balance between oxygen supply and utilization directly in tissue microvessels (venules, arterioles, and capillaries), with a predominant venous contribution (70 to 80%).(20,21) Hence, NIRS appears suitable…”
MethodAcute effect of fish protein hydrolysate supplementation on vascular function in healthy individuals
Álvares, T. S., Conte‐Júnior, C. A., Pierucci, A. P. T. R., de Oliveira, G. V., & Cordeiro, E. M. (2018) · Journal of Functional Foods · doi:10.1016/j.jff.2018.04.066 · Cited by 33
Manchado-Gobatto, F. D. B., Marostegan, A. B., Rasteiro, F. M., Cirino, C., da Cruz, J. P., Moreno, M. A., & Gobatto, C. A. (2020) · Scientific Reports · doi:10.1038/s41598-020-63297-w · Cited by 36
Matsumura, M., Ueda, C., Shiroishi, K., Esaki, K., Ohmori, F., Yamaguchi, K., Ichimura, S., Kurosawa, Y., Kime, R., Osada, T., et al. (2008) · Dynamic Medicine · doi:10.1186/1476-5918-7-1 · Cited by 39
“In contrast to conventional invasive methods [12] that present a great burden to patients, the use of a simple and non-invasive near infrared spectroscopy (NIRS) to monitor muscle oxidative metabolic function has come under attention [13-17].”
BackgroundSelf-citationPhysiological and biomechanical responses to a prolonged repetitive asymmetric lifting activity
Mehta, J. P., Lavender, S. A., & Jagacinski, R. J. (2014) · Ergonomics · doi:10.1080/00140139.2014.887788 · Cited by 32
“Recently, near-infrared spectroscopy (NIRS) has been used to quantify changes in muscle physiology (McGill, Hughson, and Parks 2000; Hamaoka et al. 2007).”
MethodBlasi, R. A. D., Luciani, R., Punzo, G., Arcioni, R., Romano, R., Boezi, M., & Mené, P. (2009) · Critical Care · doi:10.1186/cc8007 · Cited by 39
“Previous data obtained with NIRS technology already document higher Hb desaturation in patients with peripheral vascular disease and diabetes during exercise [30].”
BackgroundTime-Trial Performance in Elite Speed Skaters After Remote Ischemic Preconditioning
Richard, P., & Billaut, F. (2018) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2018-0111 · Cited by 40
Mitochondrial dysfunction measured in vivo
Marcinek, D. J. (2004) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.2004.01372.x · Cited by 38
Dry Cupping Therapy for Improving Nonspecific Neck Pain and Subcutaneous Hemodynamics
Stephens, S., Selkow, N. M., & Hoffman, N. L. (2020) · Journal of Athletic Training · doi:10.4085/1062-6050-236-19 · Cited by 31
Biomedical applications of wireless continuous wave near infrared spectroscopy
Macnab, A. J., & Shadgan, B. (2012) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-2012-0018 · Cited by 33
“Recent reviews celebrated the first 30 years of such applications [37,120]; the twentieth anniversary of human functional near-infrared spectroscopy (fNIRS) [30] and publication of the Journal of Near Infrared Spectroscopy [29]; and a 2010 discussion meeting at the Royal Society in London “Making…”
RYAN, T. E., Erickson, M. L., Young, H., & McCully, K. K. (2013) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2013.06.014 · Cited by 31
Self-citationMuscle oxygen dynamics in elite climbers during finger-hang tests at varying intensities
Feldmann, A., Erlacher, D., Pfister, S., & Lehmann, R. (2020) · Scientific Reports · doi:10.1038/s41598-020-60029-y · Cited by 32
Kreis, R., Bruegger, K., Skjelsvik, C., Zwicky, S., Ith, M., Jung, B., Baumgärtner, I., & Boesch, C. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1184 · Cited by 31
Ohmae, E., Nishio, S., Oda, M., Suzuki, H., Suzuki, T., Ohashi, K., Koga, S., Yamashita, Y., & Watanabe, H. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.6.067005 · Cited by 33
A new measurement method for spine reposition sense
Petersen, C. M., Zimmermann, C. L., Cope, S. M., Bulow, M. E., & Ewers-Panveno, E. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-9 · Cited by 30
Quantifying the effect of adipose tissue in muscle oximetry by near infrared spectroscopy
Nasseri, N., Kleiser, S., Ostojic, D., Karen, T., & Wolf, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004605 · Cited by 34
Moalla, W., Dupont, G., Berthoin, S., & Ahmaidi, S. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830332 · Cited by 30
Draghici, A. E., Potart, D., Hollmann, J. L., Pera, V., Fang, Q., DiMarzio, C. A., Taylor, J. A., Niedre, M. J., & Shefelbine, S. J. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23622 · Cited by 30
Peltonen, J. E., Hägglund, H., Koskela-Koivisto, T., Koponen, A. S., Aho, J. M., Rissanen, A., Shoemaker, J. K., Tiitinen, A. E., & Tikkanen, H. O. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.05.014 · Cited by 32
Flodgren, G., Hellström, F., Fahlström, M., & Crenshaw, A. G. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0216-7 · Cited by 29
Fuse, S., Nirengi, S., Amagasa, S., Homma, T., Kime, R., Endo, T., Sakane, N., Matsushita, M., Saito, M., Yoneshiro, T., et al. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.6.065002 · Cited by 30
“Moreover, according to a recent study, the mean depth of the light penetration with a 3-cm optode separation using NIRTRS would be ∼2 cm,(30) which is greater than half of the emitter– detector separation reported in many previous studies.(29,33,34) Although NIRTRS is noninvasive, uncomplicated, less expensive than PE…”
MethodSelf-citationMuscle and cerebral oxygenation during exercise performance after short-term respiratory work
Keramidas, M. E., Kounalakis, S. N., Eiken, O., & Mekjavic, I. B. (2011) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.11.009 · Cited by 26
Rashnavadi, T., Macnab, A. J., Cheung, A., Shadgan, A., Kwon, B. K., & Shadgan, B. (2019) · Spinal Cord · doi:10.1038/s41393-019-0304-2 · Cited by 29
Paradis‐Deschênes, P., Joanisse, D. R., Mauriège, P., & Billaut, F. (2020) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.00041 · Cited by 29
STÖGGL, T. L., & Born, D. (2021) · Sensors · doi:10.3390/s21072535 · Cited by 31
Metadata
- Authors
- Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B.
- Affiliations
- Tokyo Medical College
- University of Georgia (US)
- University of L'Aquila (IT)
- Hokkaido University (JP)
- University of Pennsylvania (US)
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2007-11-01
- Volume
- 12
- Issue
- 06
- Pages
- 1-16
- ISSN
- 1083-3668 (ISSN-L)
- 1560-2281
- OpenAlex
- W4297832436
- Semantic Scholar
- 2bda5bdb3ef3a60cc093249ee0e38d98c8f71ea5
- Cited by
- 329
- References
- 222
- Citations by year
- 2026: 15 · 2025: 6 · 2024: 14 · 2023: 12 · 2022: 18 · 2021: 19 · 2020: 19 · 2019: 25 · 2018: 17 · 2017: 21 · 2016: 18 · 2015: 20 · 2014: 13 · 2013: 17 · 2012: 26
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomedical Optics (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- near-infrared spectroscopy, near-infrared imaging, muscle oxygenation, skeletal muscle oxidative metabolism, muscle oxygen dynamics, signal quantification, physical activity, ischemia, chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, myopathy, spinal cord injury, renal failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.