Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans
Open accessThe DOI matches its Crossref record; 148 of the 230 references it cites were found in a registry or an index, and 81 are not checked yet.
Abstract
Near-infrared spectroscopy (NIRS) was initiated in 1977 by Jobsis as a simple, noninvasive method for measuring the presence of oxygen in muscle and other tissues in vivo. This review honoring Jobsis highlights the progress that has been made in developing and adapting NIRS and NIR imaging (NIRI) technologies for evaluating skeletal muscle O2 dynamics and oxidative energy metabolism. Development of NIRS/NIRI technologies has included novel approaches to quantification of the signal, as well as the addition of multiple source detector pairs for imaging. Adaptation of NIRS technology has focused on the validity and reliability of NIRS measurements. NIRS measurements have been extended to resting, ischemic, localized exercise, and whole body exercise conditions. In addition, NIRS technology has been applied to the study of a number of chronic health conditions, including patients with chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, varying muscle diseases, spinal cord injury, and renal failure. As NIRS technology continues to evolve, the study of skeletal muscle function with NIRS first illuminated by Jobsis continues to be bright.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When debating a specific gold standard to which NIRS-derived SmO2 should be compared, an obvious lack of authority exists as the term is not mentioned in reviews,6,20,21 with appropriate hesitation.”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [20]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationOwen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Self-citationDuncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Mancini, D. M., Katz, S. D., Lang, C. C., LaManca, J., Hudaihed, A., & Androne, A.-S. (2003) · Circulation · doi:10.1161/01.cir.0000044914.42696.6a · Cited by 542
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 3×
“light source to the detector is that it follows a banana-shaped curve, in which the penetration depth into the tissue is approximately equal to half the distance between the light source and the detector.(23) If light source-detector separation”
BackgroundMethodSelf-citationAbnormal Cardiac and Skeletal Muscle Energy Metabolism in Patients With Type 2 Diabetes
Scheuermann-Freestone, M., Madsen, P. L., Manners, D., Blamire, A. M., Buckingham, R. E., Styles, P., Radda, G. K., Neubauer, S., & Clarke, K. (2003) · Circulation · doi:10.1161/01.cir.0000072789.89096.10 · Cited by 525
Research works printed but not linked: 9
- V. Quaresima, R. Lepanto, and M. Ferrari, "The use of near infrared spectroscopy in sports medicine," J. Sports Med. Phys. Fitness 43, 1-13 ͑2003͒.
- K. K. McCully and T. Hamaoka, "Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle?," Exerc Sport Sci. Rev. 28, 123-127 ͑2000͒.
- M. Niwayama, K. Yamamoto, D. Kohata, K. Hirai, N. Kudo, T. Hamaoka, R. Kime, and T. Katsumura, "A 200-channel imaging sys- tem of muscle oxygenation using CW near-infrared spectroscopy," IEICE Trans. Inf. Syst. E85-D, 115-123 ͑2002͒.
- B. Chance, D. J. Wang, S. Nioka, Z. Wang, E. A. Noyszewski, T. Hamaoka, and J. S. Leigh, Jr., "Myoglobin and hemoglobin deoxy- genation during muscle exercise in dogs," Specialty Conf. Am. Col- lege Sports Med. Regulation Oxidative Metab. Blood Flow Skele. Muscle abstract, p. 20 ͑1995͒.
- O. Piazza, G. Zito, A. Valente, and R. Tufano, "Effects of dopamine infusion on forearm blood flow in critical patients," Med. Sci. Monit 12, CR90-93 ͑2006͒.
- Buono, 2005, Eur. J. Vasc. Surg., 55, 241
- Komiyama, 1996, Int. Angiol, 15, 215
- Belardinelli, 1995, G. Ital. Cardiol., 25, 715
- Tateishi, 2005, Osaka City Med. J., 51, 65
Cited by
Items 601–652 of 652
Sepúlveda, R. Y. (2023) · Buleria (Universidad de León) · doi:10.18002/10612/18621
Muscular Oxygen Saturation and Hemoglobin Concentration during Freediving: A Case Study
Vrdoljak, D., Dujić, Ž., & Foretić, N. (2024) · Oxygen · doi:10.3390/oxygen4030016
Optimizing Initial Resuscitation: Clinical and Perfusion Parameters in Septic Shock
Yumoto, T. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1005807
Sakaue, T., Tsutsui, A., Togo, S., Takeda, T., Nakajima, K., & Fukuda, K. (2024) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-67458-7_55
Piñero-Saez, S., López‐González, Á., Guisado-Requena, I. M., López-Tendero, J., Guerrero-Agenjo, C. M., García-Alcaráz, F., González-Moro, I. M., & Rabanales-Sotos, J. (2024) · Frontiers in Emergency Medicine · doi:10.18502/fem.v8i4.17080
McCully, K. K., Reynolds, M. A., Erickson, M. L., & Tansey, K. E. (2024) · Case Reports in Clinical Medicine · doi:10.4236/crcm.2024.1312064
“…Artinis Medical Systems, Zetten, Netherlands) used in this study measured the absorption properties of hemoglobin and myoglobin at 760 and 850 nm, and the difference signal between these two wavelengths used to measure relative changes in oxygen levels within the tissue over time [24] [26]-[29].”
Self-citationCoşkun, E., Alokten, M., Karakulak, E. Z., Aysal, F., & Hanoğlu, L. (2024) · Nöro Psikiyatri Arşivi · doi:10.29399/npa.28877
Penggunaan Near Infrared Spectroscopy untuk Evaluasi Kaki Diabetes
Kartika, R. W., & Timotius, K. H. (2025) · Cermin Dunia Kedokteran · doi:10.55175/cdk.v52i2.1208
Ly, S., & Kurzrock, E. A. (2024) · Journal of Pediatric Rehabilitation Medicine · doi:10.1177/18758894241304358
Gabler, M. C., Martin, B. J., Johnson, B. D., Schlader, Z. J., & Chapman, R. F. (2025) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2024-0425
Insights From Bone and Muscle Oxygenation Toward a More Comprehensive Model of Tissue Healing
Tian, Y., Hakim, A. H., Anderson, C. P., Sharma, P., Al-Gahmi, A.-M., Kim, K., Park, S., Koutakis, P., Sachdev, U., Draghici, A. E., et al. (2025) · Journal of Surgical Research · doi:10.1016/j.jss.2025.08.015
Malczewska‐Lenczowska, J., Klusiewicz, A., Rębiś, K., Czaplicki, A., Kowalski, T., Granda, D., Starczewski, M., & Konopka, M. A. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05955-3
“Thus, the adipose tissue thickness in the VL area should not have interfered with the NIRS signal.”
InfluentialNeuromuscular factors affecting stretch-induced torque loss
Trajano, G. S. (2014) · Research Online (Edith Cowan University)
Danga, F. (2023) · University of Thessaly Institutional Repository (University of Thessaly) · doi:10.26253/heal.uth.37629
Moio, P., Ribeiro, L., & Ferreira, D. (2021) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Lucero, A. A. (2021) · Massey Research Online (Massey University) · Cited by 1
Fatigue Monitorin in Rehabilitation with the Vibramoov Platform
Lukešová, M. (2025) · DSpace VŠB-TUO (VŠB-TUO)
Whyte, E. (2021) · TSpace (University of Toronto)
Pelvan, S. O. (2013) · Dspace Repository (Marmara Üniversitesi) · Cited by 1
Muscle Near-Infrared Spectroscopy: mNIRS the Next Generation of Applied Muscle Physiology
Feldmann, A. (2025) · Springer eBooks · doi:10.1007/978-3-662-70475-2_17 · Cited by 1
Measuring Muscle Post-Exercise Oxygen Consumption in Individuals with a Family History of Diabetes
McCully, K. K., Kachappilly, O., Flame, C., & Jain, A. (2026) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk11010055
Self-citationPek, B. (2024) · Dspace Repository (Marmara Üniversitesi)
Koca, Ş. (2024) · Dspace Repository (Marmara Üniversitesi)
Martínez, A. J. (2025) · RIUCAM · Cited by 1
Exercise testing and microvascular assessment in ICU survivors to investigate ICU-acquired weakness
Blunderfield, B. (2025) · Mspace (University of Manitoba)
Berriri, A. (2017) · theses.fr (ABES) · doi:10.70675/a3dabc63z75cbz4d4fzb96azc3ff3f971516
Low-cost point-of-care wireless multimodal wearable to monitor vitals and tissue oxygen saturation
Nguyen, T. K., George, T. M., Veluvolu, V. D., Azar, T. S., Frankenberg, A., Park, J., Park, J., Martin, W. S., Khaksari, K., Shadgan, B., et al. (2026) · Journal of Physics Photonics · doi:10.1088/2515-7647/ae637f
“In this context, the observed elevation in StO ₂ reflects an increase in oxygenated blood volume within the chest microvasculature [23].”
Muscle Oxygenation During Exercise in Patients with Peripheral Artery Disease: A Systematic Review
Salamifar, Z., Fallahtafti, F., Pipinos, I. I., Anderson, C. P., Park, S., & Myers, S. A. (2026) · Applied Sciences · doi:10.3390/app16094348
Liu, J., Kelhofer, N. C., Burtner, T. S., Cheung, W. C., Hernandez, M. E., & Jan, Y. (2026) · Diagnostics · doi:10.3390/diagnostics16111585
Hálasz, G., Mistrulli, R., Francesco, M. D., Giacalone, G., Ferri, G., Beato, S., Orsini, F. M., Nardecchia, G., Corica, B., Colivicchi, F., et al. (2026) · Healthcare · doi:10.3390/healthcare14111511
“This is particularly relevant because exercise intolerance is often not exclusively cardiac in origin, but may also reflect abnormalities in microvascular function, muscle perfusion, oxidative metabolism, or mitochondrial capacity [3,4].”
McGregor, C., Marley, A., & Babraj, J. (2026) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000005594
Manchado-Gobatto, F. D. B., Torres, R. D. S., Rasteiro, F. M., Pinto, A. D. S., Scariot, P. P. M., Marostegan, A. B., da Cruz, J. P., Orsi, J. B., de Araujo, L. S., & Gobatto, C. A. (2026) · Physiological Reports · doi:10.14814/phy2.71054
Nochi, Z., Kristensen, S. K., Mehrani, N., Guerreiro, I., Nørholm, I. M. D., Chandra, S., Olufsen, M. S., Gudbergsen, L. R., Brinth, L. S., Stokholm, R., et al. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-117729
Yu, Y., Fili, M., van der Weyden, M. S., Martin, J., Wang, L., Yu, L.-F., & Hu, G. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7329427
Investigation of muscle oxygen saturation response according to quadriceps muscle strength levels
Pündük, Z., Nizam, S., Demirci, S., & Atik, A. (2026) · Isokinetics and Exercise Science · doi:10.1177/09593020261480974
“These associations suggest that greater muscle strength may be accompanied by modest increases in local blood volume during high-velocity contractions, but they do not contradict the mixed-design ANOVA findings showing no differential response between strength groups.”
Jeong, H., Yu, J., 김효진, & Kim, C. (2026) · 한국생활환경학회지 · doi:10.21086/ksles.2026.8.33.4.437
Citius, Maius, Melius: Mitochondria and Endurance Performance
Botella, J., Bishop, D. J., & Granata, C. (2026) · Sports Medicine · doi:10.1007/s40279-026-02530-4
A Reconfigurable Lightmyography Armband with Targeted Sensor Placement and Tightening
Zhuwawu, S. S., Owen, M., Bifet, A., & Dwivedi, A. (2026) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob66782.2026.11681566
Muscle Near-Infrared Spectroscopy: mNIRS the Next Generation of Applied Muscle Physiology
Feldmann, A. (2026) · Springer eBooks · doi:10.1007/978-3-662-73013-3_14
Viškere, D., Matise, I., Cugmas, B., & Tamošiūnas, M. (2026) · Frontiers in Veterinary Science · doi:10.3389/fvets.2026.1758597
Regmi, K., & Kohli, E. (2026) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2026.107022
Hardy, M. (2026) · Constellation (Université du Québec à Chicoutimi)
İlhan, M. (2025) · Dspace Repository (Marmara Üniversitesi)
Achylov, R. (2025) · Marmara University Open Access System
Engan, H. K., Schagatay, E. K. A., & Holmberg, H. (2015)
Estimation of oxygen extraction in exercising muscle by near infrared spectroscopy
Hirakoba, K. (2001) · Institutional Repositories DataBase (IRDB)
Changes in tendon compliance and muscle energetics of in vivo human skeletal muscle
Fletcher, J. R. (2014) · Libraries and Cultural Resources (University of Calgary) · doi:10.5072/prism/25251
Metadata
- Authors
- Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B.
- Affiliations
- Tokyo Medical College
- University of Georgia (US)
- University of L'Aquila (IT)
- Hokkaido University (JP)
- University of Pennsylvania (US)
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2007-11-01
- Volume
- 12
- Issue
- 06
- Pages
- 1-16
- ISSN
- 1083-3668 (ISSN-L)
- 1560-2281
- OpenAlex
- W4297832436
- Semantic Scholar
- 2bda5bdb3ef3a60cc093249ee0e38d98c8f71ea5
- Cited by
- 329
- References
- 222
- Citations by year
- 2026: 15 · 2025: 6 · 2024: 14 · 2023: 12 · 2022: 18 · 2021: 19 · 2020: 19 · 2019: 25 · 2018: 17 · 2017: 21 · 2016: 18 · 2015: 20 · 2014: 13 · 2013: 17 · 2012: 26
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomedical Optics (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- near-infrared spectroscopy, near-infrared imaging, muscle oxygenation, skeletal muscle oxidative metabolism, muscle oxygen dynamics, signal quantification, physical activity, ischemia, chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, myopathy, spinal cord injury, renal failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.