The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Photoacoustic imaging and characterization of the microvasculature
Open accessAbstract
Photoacoustic (optoacoustic) tomography, combining optical absorption contrast and highly scalable spatial resolution (from micrometer optical resolution to millimeter acoustic resolution), has broken through the fundamental penetration limit of optical ballistic imaging modalities-including confocal microscopy, two-photon microscopy, and optical coherence tomography-and has achieved high spatial resolution at depths down to the diffusive regime. Optical absorption contrast is highly desirable for microvascular imaging and characterization because of the presence of endogenous strongly light-absorbing hemoglobin. We focus on the current state of microvascular imaging and characterization based on photoacoustics. We first review the three major embodiments of photoacoustic tomography: microscopy, computed tomography, and endoscopy. We then discuss the methods used to characterize important functional parameters, such as total hemoglobin concentration, hemoglobin oxygen saturation, and blood flow. Next, we highlight a few representative applications in microvascular-related physiological and pathophysiological research, including hemodynamic monitoring, chronic imaging, tumor-vascular interaction, and neurovascular coupling. Finally, several potential technical advances toward clinical applications are suggested, and a few technical challenges in contrast enhancement and fluence compensation are summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationWater-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Self-citationMultiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Self-citationBiomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Self-citationMalonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,097
On the production and reproduction of sound by light
Bell, A. G. (1880) · American Journal of Science · doi:10.2475/ajs.s3-20.118.305 · Cited by 1,082
Imaging of angiogenesis: from microscope to clinic
McDonald, D. M., & Choyke, P. L. (2003) · Nature Medicine · doi:10.1038/nm0603-713 · Cited by 1,016
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832 · cited 1×
“invasive preparation and enable volumetric visualization of the microvasculature.(10,11) However, their imaging contrasts”
BackgroundOrthogonal polarization spectral imaging: A new method for study of the microcirculation
Groner, W., Winkelman, J. W., Harris, A. G., Ince, C., Bouma, G. J., Messmer, K., & Nadeau, R. G. (1999) · Nature Medicine · doi:10.1038/13529 · Cited by 810
Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763
Self-citationThree dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Tutorial on Photoacoustic Microscopy and Computed Tomography
Wang, L. V. (2008) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.913398 · Cited by 607
Self-citationProspects of photoacoustic tomography
Wang, L. V. (2008) · Medical Physics · doi:10.1118/1.3013698 · Cited by 561
Self-citationWang, X., Xie, X., Ku, G., Wang, L. V., & Stoica, G. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2192804 · Cited by 505
Self-citationWhite, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
Rudd, J. H. F., Myers, K. S., Bansilal, S., Machac, J., Pinto, C. A., Tong, C., Rafique, A., Hargeaves, R., Farkouh, M., Fuster, V., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.050294 · Cited by 444
Culver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
In vivo dark-field reflection-mode photoacoustic microscopy
Maslov, K., Stoica, G., & Wang, L. V. (2005) · Optics Letters · doi:10.1364/ol.30.000625 · Cited by 413
Self-citationYang, X., Skrabalak, S. E., Li, Z.-Y., Xia, Y., & Wang, L. V. (2007) · Nano Letters · doi:10.1021/nl072349r · Cited by 407
Self-citationZhang, H. F., Maslov, K., Sivaramakrishnan, M., Stoica, G., & Wang, L. V. (2007) · Applied Physics Letters · doi:10.1063/1.2435697 · Cited by 380
Self-citationLi, M.-L., Oh, J.-T., Xie, X., Ku, G., Wang, W., Li, C., Lungu, G., Stoica, G., & Wang, L. V. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2007.913515 · Cited by 352
Self-citationVasomotion: Mechanisms and Physiological Importance
Nilsson, H. (2003) · Molecular Interventions · doi:10.1124/mi.3.2.79 · Cited by 342
Laufer, J., Delpy, D., Elwell, C., & Beard, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/1/010 · Cited by 319
In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy
Zhang, E. Z., Laufer, J. G., Pedley, R. B., & Beard, P. C. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/4/014 · Cited by 298
Zharov, V. P., Galanzha, E. I., Shashkov, E. V., Khlebtsov, N. G., & Tuchin, V. V. (2006) · Optics Letters · doi:10.1364/ol.31.003623 · Cited by 229
Yang, J.-M., Maslov, K., Yang, H.-C., Zhou, Q., Shung, K. K., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.34.001591 · Cited by 229
Self-citationWang, B., Yantsen, E., Larson, T., Karpiouk, A. B., Sethuraman, S., Su, J. L., Sokolov, K., & Emelianov, S. Y. (2009) · Nano Letters · doi:10.1021/nl801852e · Cited by 208
Serial noninvasive photoacoustic imaging of neovascularization in tumor angiogenesis
Siphanto, R. I., Thumma, K. K., Kolkman, R. G. M., van Leeuwen, T. G., de Mul, F. F. M., van Neck, J. W., van Adrichem, L. N. A., & Steenbergen, W. (2005) · Optics Express · doi:10.1364/opex.13.000089 · Cited by 205
Optical contrast agents and imaging systems for detection and diagnosis of cancer
Pierce, M. C., Javier, D. J., & Richards‐Kortum, R. (2008) · International Journal of Cancer · doi:10.1002/ijc.23858 · Cited by 204
Spectroscopic intravascular photoacoustic imaging to differentiate atherosclerotic plaques
Sethuraman, S., Amirian, J. H., Litovsky, S. H., Smalling, R. W., & Emelianov, S. Y. (2008) · Optics Express · doi:10.1364/oe.16.003362 · Cited by 197
Zijlstra, W. G., Buursma, A., & van Assendelft, O. W. (2021) · CRC Press eBooks · doi:10.1201/9780429071096 · Cited by 190
Thermoacoustic Molecular Imaging of Small Animals
Kruger, R. A., Kiser, W. L., Reinecke, D. R., Kruger, G. A., & Miller, K. D. (2003) · Molecular Imaging · doi:10.1162/15353500200303109 · Cited by 187
Aalkjær, C., & Nilsson, H. (2005) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0706084 · Cited by 186
(2007) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2007.05.034 · Cited by 185
Picomolar sensitivity MRI and photoacoustic imaging of cobalt nanoparticles
Bouchard, L.-S., Anwar, M. S., Liu, G. L., Hann, B., Xie, Z. H., Gray, J. W., Wang, X., Pines, A., & Chen, F. F. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813019106 · Cited by 183
Deep reflection-mode photoacoustic imaging of biological tissue
Song, K. H., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2818045 · Cited by 181
Self-citationZharov, V. P., Galanzha, E. I., Shashkov, E. V., Kim, J.-W., Khlebtsov, N. G., & Tuchin, V. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793746 · Cited by 177
Photoacoustic Doppler Effect from Flowing Small Light-Absorbing Particles
Fang, H., Maslov, K., & Wang, L. V. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.184501 · Cited by 171
Self-citationPhotoacoustic imaging of biological tissue with intensity-modulated continuous-wave laser
Maslov, K., & Wang, L. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904965 · Cited by 168
Self-citationIntravascular photoacoustic imaging using an IVUS imaging catheter
Sethuraman, S., Aglyamov, S., Amirian, J., Smalling, R., & Emelianov, S. (2007) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.343 · Cited by 166
Dynamics of the Vascular System
Li, J. K. ‐. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/4923 · Cited by 153
Noninvasive photoacoustic imaging of the developing vasculature during early tumor growth
Lao, Y., Xing, D., Yang, S., & Xiang, L. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/013 · Cited by 153
Quantum Dots as Multimodal Photoacoustic and Photothermal Contrast Agents
Shashkov, E. V., Everts, M., Galanzha, E. I., & Zharov, V. P. (2008) · Nano Letters · doi:10.1021/nl802442x · Cited by 150
Tumor‐vascular interactions and tumor dormancy
Naumov, G. N., Folkman, J., Straume, O., & Akslen, L. A. (2008) · Apmis · doi:10.1111/j.1600-0463.2008.01213.x · Cited by 130
Galanzha, E. I., Shashkov, E. V., Tuchin, V. V., & Zharov, V. P. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20587 · Cited by 127
Clinical testing of a photoacoustic probe for port wine stain depth determination
Viator, J. A., Au, G., Paltauf, G., Jacques, S. L., Prahl, S. A., Ren, H., Chen, Z., & Nelson, J. S. (2002) · Lasers in Surgery and Medicine · doi:10.1002/lsm.10015 · Cited by 127
In vivo volumetric imaging of subcutaneous microvasculature by photoacoustic microscopy
Zhang, H. F., Maslov, K., Li, M., Stoica, G., & Wang, L. V. (2006) · Optics Express · doi:10.1364/oe.14.009317 · Cited by 123
Self-citationNoninvasive label-free imaging of microhemodynamics by optical-resolution photoacoustic microscopy
Hu, S., Maslov, K., & Wang, L. V. (2009) · Optics Express · doi:10.1364/oe.17.007688 · Cited by 117
Self-citationHypoxia- or hyperoxia-induced changes in arteriolar vasomotion in skeletal muscle microcirculation
Bertuglia, S., Colantuoni, A., Coppini, G., & Intaglietta, M. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.2.h362 · Cited by 115
Photoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer
Zemp, R. J., Bitton, R. R., Shung, K. K., Li, M.-L., Stoica, G., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2709850 · Cited by 113
Self-citationKarpiouk, A. B., Aglyamov, S. R., Mallidi, S., Shah, J., Scott, W. G., Rubin, J. M., & Emelianov, S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2992175 · Cited by 99
Optoacoustic tomography using time-resolved interferometric detection of surface displacement
Payne, B. P., Venugopalan, V., Mikic, B. B., & Nishioka, N. S. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1559727 · Cited by 78
Photoacoustic determination of blood vessel diameter
Kolkman, R. G. M., Klaessens, J. H. G. M., Hondebrink, E., Hopman, J. C. W., de Mul, F. F. M., Steenbergen, W., THIJSSEN, J. M., & van Leeuwen, T. G. J. M. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/20/006 · Cited by 77
Molecular imaging of tumor angiogenesis
Costouros, N. G., Diehn, F. E., & Libutti, S. K. (2002) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10426 · Cited by 75
Hu, S., Maslov, K., & Wang, L. V. (2009) · Medical Physics · doi:10.1118/1.3137572 · Cited by 68
Self-citationPhotoacoustic Doppler Flow Measurement in Optically Scattering Media
Fang, H., Maslov, K., & Wang, L. V. (2007) · Applied Physics Letters · doi:10.1063/1.2825569 · Cited by 64
Self-citationIn vivo port-wine stain depth determination with a photoacoustic probe
Viator, J. A., Choi, B., Ambrose, M., et al. (2003) · Applied Optics · doi:10.1364/ao.42.003215 · Cited by 63
Label-free in vivo optical imaging of microvasculature and oxygenation level
Fu, D., Matthews, T. E., Ye, T., Piletic, I. R., & Warren, W. S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2968260 · Cited by 53
Schminke, U., Motsch, L., Griewing, B., Gaull, M., & Kessler, C. (2000) · Journal of Neurology · doi:10.1007/pl00007790 · Cited by 46
Functional and molecular MR imaging of angiogenesis: Seeing the target, seeing it work
Neeman, M. (2002) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10399 · Cited by 43
M-mode photoacoustic particle flow imaging
Fang, H., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.34.000671 · Cited by 39
Self-citationPhotoacoustic flow measurements by use of laser-induced shape transitions of gold nanorods
Li, P., Huang, S.-W., Wei, C., Chiou, Y.-C., Chen, C.-D., & Wang, C. C. (2005) · Optics Letters · doi:10.1364/ol.30.003341 · Cited by 38
Photoacoustic flow measurements based on wash-in analysis of gold nanorods
Wei, C., Huang, S.-W., Wang, C.-R. C., & Li, P. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.367 · Cited by 36
Automatic algorithm for skin profile detection in photoacoustic microscopy
Zhang, H. F., Maslov, K., & Wang, L. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3122362 · Cited by 35
Self-citationOptoacoustic determination of optical attenuation depth using interferometric detection
Payne, B. P., Venugopalan, V., Mikic, B. B., & Nishioka, N. S. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1559731 · Cited by 28
Quantitating Therapeutic Disruption of Tumor Blood Flow with Intravital Video Microscopy
Iga, A. M., Sarkar, S., Sales, K. M., Winslet, M. C., & Seifalian, A. M. (2006) · Cancer Research · doi:10.1158/0008-5472.can-06-1743 · Cited by 22
Cited by
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
The unique role of nanoparticles in nanomedicine: imaging, drug delivery and therapy
Doane, T. L., & Burda, C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15260f · Cited by 1,098
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
Yao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Self-citationNoninvasive Imaging of Nanomedicines and Nanotheranostics: Principles, Progress, and Prospects
Kunjachan, S., Ehling, J., Storm, G., Kiessling, F., & Lammers, T. (2015) · Chemical Reviews · doi:10.1021/cr500314d · Cited by 480
Metadata
- Authors
- Hu, S., & Wang, L. V.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2010
- Volume
- 15
- Issue
- 1
- Pages
- 011101
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2109329707
- Cited by
- 427
- References
- 68
- FWCI
- 19.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.